• 제목/요약/키워드: large motor-generator

검색결과 54건 처리시간 0.019초

자동변속기의 변속특성시뮬레이션을 위한 HILS시스템 개발 (A Development of Hardware-in-the-Loop Simulation System of Automatic Transmission for the Simulation of Shifting Characteristics)

  • 정규홍;이교일
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.143-151
    • /
    • 2001
  • During the past several years, the major interests of car manufacturers in development of automatic transmission were in durability and shift quality. However, a large number of researches for improving shift quality that are based on dynamic characteristics of shifting mechanism have been rarely adopted in the developing process because it is quite difficult to predict the shifting performance from the dynamics simulation. One of the important reasons for the difference between simulation results and experiments arises from the automatic transmission hydraulic system that consists of many valves with high order model and shows a lot different dynamics to temperature variation. In this work, hardware-in-the-loop simulation system for automatic transmission was developed f3r improving the accuracy of simulated result by combining the real-time simulation model with the real hydraulic system. The real-time simulation for automatic transmission model excluding hydraulic system is executed with TI's TMS320C31 DSP and the interfacing board which includes 12bit A/D, PWM signal generator and driver, serial driver ,etc is designed for acquiring the simulation data and signal interface with hydraulic system. We verified the proper operation and correctness of shifting result by comparing the off-line simulation result with that of HILS and experimental result which was performed on transmission dynamometer driven by electric motor.

  • PDF

Frequency Tracking of Resonance Frequency Variation of L-C Circuits for Wireless Energy Transmission to Medical Devices in Human Organs

  • Gimm, Yoon-Myoung;Ju, Young-Jun;Lee, Yu-Ri;Lee, Dong-Yeol;Wang, Jong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • 제11권4호
    • /
    • pp.298-303
    • /
    • 2011
  • A capsular endoscope (CE) for inspection of the large intestine requires a motor for backward navigation against the autonomous travel in the intestine. This study proposes an HF power system for generating a magnetic field and for delivering wireless power to the internal or implanted medical devices. The magnetic field is generated by a wound coil (L) around a wooden frame, and the current is driven to the coil through a resonating capacitor (C). The characteristics of the resonance frequency shifting of the L-C series circuit are analyzed. A stable magnetic field intensity in the field coil is maintained by a specially designed frequency tracking system that automatically follows the L-C resonance frequency. Testing confirmed that the oscillation system tracks well the parameter changes of the electric components caused by the operating conditions or environmental variations.

호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템 (A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules)

  • 이인광;박미정;이상봉;김경옥;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

2차원 유한요소법을 적용한 플라이휠 에너지 저장 장치 동특성 해석 프로그램 개발 (Development of Rotordynamics Program Based on the 2D Finite Element Method for Flywheel Energy Storage System)

  • 구동식;배용채;이욱륜;김재구;김효중;최병근
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1757-1763
    • /
    • 2010
  • 플라이휠 에너지 저장 장치는 잉여 전기를 회전관성을 통해 운동 에너지로 저장하는 장치로, 회전의 중심이 되는 축과 외부의 플라이휠로 구성이 된다. 수치해석을 위한 일반적 프로그램들은 3차원의 모델을 통하여 구조해석 및 주파수 응답 등의 해석을 수행하게 된다. 허나 상용 프로그램을 이용한 동역학적 해석의 응용은 매우 어려운 실정이며, 사용자가 그 방법을 익히는 것 또한 쉽지 않다. 이러한 문제들을 보완하고자 동역학적 해석을 위한 프로그램을 2차원의 모델을 사용하여 구축하였다. 본 논문에서 제시한 모델링은 회전체를 2차원으로 표현함으로써 3차원에 비해 시스템의 표현을 보다 단순화하여 시스템의 구조를 쉽게 이해할 수 있도록 하였으며, 회전체를 서로 다른 재질의 다중 레이어로 모델이 가능하게 하였다. 또한 축계에 추가적 강성의 영향을 줄 수 있는 열박음 부분에 대하여, 그 영향 정도를 선택적으로 입력할 수 있게 하여 열박음에 대한 효과를 조정할 수 있도록 하였다. 따라서 본 논문에서 제시하는 2차원 모델을 이용한 동특성 해석 프로그램의 해석 오차를 알아보기 위해 상용 프로그램의 해석 결과와 비교하였으며, 모델링을 위한 시간과 해석 수행 시간 역시 비교하였다.