• 제목/요약/키워드: large electric field

검색결과 376건 처리시간 0.025초

지진전조현상 파악을 위한 전기장 효과에 의한 동물 이상 행동 실험 (Experiment on the Anomalous Animal Behaviors by Electric Field Effects for detecting Earthquake Precursors)

  • 경재복;윤장근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.57-64
    • /
    • 2001
  • There are some previous reports that some animals such as rats and birds move in a large group and act abnormally to avoid the large earthquake. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezoelectric effects in a basement rock before earthquake occurrences. When electric field is applied to the whole bottom of the cage, they show nervous behaviors such as grooming, washing their faces, standing on legs or running around in panic to avoid the electric field. When more strong electric field is applied, they jump with shrieking and mount on the electric line. The rat shows more sensitive anomalous behavior than the bird. Even though the current to the experimental birds and rats is just a few $\mu$A, they react in various ways. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake. This kind of study is quite worthy for the understanding of earthquake precursors.

  • PDF

경계요소법을 이용한 표면 거침도에 따른 아라미드 절연지의 전계분포 해석 (Analysis of Electric Field Distribution according to Surface Roughness of Aramid Insulating Paper Using Boundary Element Method)

  • 김탁용;안병철;조경순;박형준;홍진웅
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.34-39
    • /
    • 2006
  • In this paper, we investigated the electric field distribution according to the roughness in aramid insulating paper for electric machine. Aramid insulating paper has been used to electric insulating of the traction motor and generators for large capacity. We studied the electric field distribution using boundary element method for Aramid insulating paper. As a result of simulation, the electric field increased according to the surface roughness existence. Electric field decreased due to radius of surface roughness reduction, and Electric field concentration appeared at electrode boundary and rough surface.

전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구 (Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube)

  • 류승관;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

FALC 공정에서의 전계 분포 전산모사 (Computer simulation of electric field distribution in FALC process)

  • 정찬엽;최덕균;정용재
    • 한국결정성장학회지
    • /
    • 제13권2호
    • /
    • pp.93-97
    • /
    • 2003
  • FALC(Field-Aided Lateral Crystallization) 공정에서 요구되는 a-Si의 결정화는 인가한 전계(electric field)의 세기와 방향에 의존한다. 본 연구에서는 유한요소법을 적용하여 실제 패턴을 간단하게 모델링한 형상에 각 물질의 전도도를 대입하고, 전안을 가해 그 결과로 발생하는 전계의 분포를 계산하였다. 전계는 (-)극 주위에서 전극의 양쪽 모서리 부근이 가운데 부분보다 더 높게 나타났고 그 방향은 전극과 50~$60^{\circ}$를 이루는 대각선 방향이었다. 또한 예상한대로 크기가 작은 패턴이 큰 패턴보다 더 큰 전계 값을 가지는 것으로 나타났다.

Experiment on the Anomalous Animal Behaviors by Electric Field Effects for Detecting Earthquake Precursors

  • Kyung, Jai-Bok;Yoon, Jang-Keun
    • 한국지구과학회지
    • /
    • 제23권1호
    • /
    • pp.112-118
    • /
    • 2002
  • The anomalous behaviour of animals prior to a large earthquake has been frequently reported from many places throughout the world since ancient times. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezo-electric effects in a basement rock before earthquake occurrences. We investigated the electric field effects on behaviors of two kinds of rats and birds. Rats show more sensitive anomalous behavior than birds. Even though the current applied to the experimental birds and rats is just a few ${\mu}$A, they show various abnormal behaviors. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake.

디지털시대의 대형사고의 전기적 영향 고찰 (Electric power system effect investigation of large size digital signal accident thought in digital age)

  • 강태근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

전장에 의한 유리와 금속의 접합 (Glass to Metal Bonding by Electric Field)

  • 정우창;김종희
    • 한국세라믹학회지
    • /
    • 제20권1호
    • /
    • pp.70-78
    • /
    • 1983
  • This paper discusses the application of Si-Borosilicate glass sealing to a new sealing method which utilizes a large electrostatic field to pormote bound formation at relatively low temperature. Bonding mechanism and the effect of bonding time bonding temperature glass thickness and surface roughness on the bond strength were investigated. Application of a de voltage across bonded specimen gradually produced a layer of glass adjacent silicon which was depleted of mobile ions. As a consequence a n increasingly larger fraction of the applied voltage appeared across the depleted region and very large electric field resulted This field accompanyed by large electrostatic force acted as driving force the of strong bond. And stronger bond was formed with increasing bonding time and temperature. A low temperature preoxidation is advantageous for the Si surface having a rougher surface finish that 1 microinch.

  • PDF

대면적 LCD용 ICP소스에 대한 수치 해석적 분석 (A Numerical Analysis on the Development of ICP Source for Large Area LCD)

  • 이주율;이영직
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.573-576
    • /
    • 1998
  • In this paper, we analyzed electric field density and plasma condition to ICP reactor geometry structure, to generate plasma, to maintain plasma uniformity of large area LCD panel in ICP reactor also, we simulated electric field density for all kind existence current (antena and plasma current) in ICP reactor to analyze plasma antena structure

  • PDF

수계 콜로이드 계에서 교류 전계에 의한 입자 배열 제어 (Control of Particle Alignment in an Aqueous Colloidal System by an AC Electric Field)

  • 황연
    • 한국재료학회지
    • /
    • 제23권1호
    • /
    • pp.13-17
    • /
    • 2013
  • The alignments of polystyrene particles of $1{\mu}m$ and $5{\mu}m$ sizes in an aqueous colloidal system were observed by varying the electric field strength, the frequency and the water flow. Spherical mono-dispersed polystyrene particles dispersed in pure water were put into a perfusion chamber; an AC electric field was applied to the Au/Cr electrodes with a 4 mm gap on the glass substrate. The mixture of the $1{\mu}m$ and $5{\mu}m$ sized polystyrene particles at 0.5 vol% concentrations for each size was set in the dielectrophoresis conditions of 1 kHz and 150 V/cm. Large particles of $5{\mu}m$ size were aligned to form chains as the result of the dielectrophoresis force interaction. On the contrary, small particles of $1{\mu}m$ size did not form chains because the dielectrophoresis force was not sufficiently large. When the electric field increased to 250 V/cm, small particles were able to form chains. After the chains were formed from both large and small particles, they began to coalescence as time passed. Owing to the electroosmotic flow of water, wave patterns along the perpendicular direction of the applied electric field appeared at the conditions of 200 Hz and 50 V/cm, when the dielectrophoresis force was small. This wave pattern also appeared for small particles at 1 kHz and 150 V/cm conditions due to the flow of solvent when water was forced to circulate.

Critical Characteristics Estimation of a Large-Scale HTS Wind Turbine Generator Using a Performance Evaluation System

  • Kim, Taewon;Woo, Sang-Kyun;Kim, Changhyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.229-233
    • /
    • 2019
  • Large-scale High Temperature Superconducting (HTS) wind power generators suffer from high electromagnetic force and high torque due to their high current density and low rotational speed. Therefore, the torque and Lorentz force of HTS wind power generators should be carefully investigated. In this paper, we proposed a Performance Evaluation System (PES) to physically test the structural stability of HTS coils with high torque before fabricating the generator. The PES is composed of the part of a pole-pair of the HTS generator for estimating the characteristic of the HTS coil. The 10 MW HTS generator and PES were analyzed using a 3D finite element method software. The performance of the HTS coil was evaluated by comparing the magnetic field distributions, the output power, and torque values of the 10 MW HTS generator and the PES. The magnetic flux densities, output power, and torque values of the HTS coils in the PES were the same as a pole-pair of the 10 MW HTS generator. Therefore, the PES-based evaluation method proposed in this paper can be used to estimate the critical characteristics of the HTS generator under high magnetic field and high torque before manufacturing the HTS wind turbines. These results will be used effectively to research and manufacture large-scale HTS wind turbine generators.