• Title/Summary/Keyword: large electric field

Search Result 376, Processing Time 0.034 seconds

Durability Estimation for ER Fluids of Methyl Cellulose Component in Smart Hydraulic Systems (지능형 유압시스템을 위한 메틸 셀루로이즈 성분 ER 유체의 내구성 평가)

  • 김옥삼;박우철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1211-1219
    • /
    • 2001
  • The electro-rheological(ER) fluids for smart hydraulic system are a class of colloidal dispersion which exhibit large reversible Changes in their rheological behavior when they are subjected to external electrical fields. This paper presents experimental results on material properties of an ER fluids subjected to electrical fatigues. As a first step, ER fluid is made of methyl cellulose(MC) choosing 25% of particle weight-concentration. Following the construction of test mechanism for durability estimation, the dynamic yield shear stress and the current density for the ER fluids of MC component are experimentally distilled as a function of electric field. In addition, the surface roughness of the employed electrode are evaluated as a function of the number of the electric-field cycles.

  • PDF

(Oscillation Characteristics in the Intergranular Layer of ZnO Varistor Fabricated 3-Composition Seed Grain Method) (3-성분 종입자법으로 제조한 ZnO 바리스터의 입계모델에서 발진특성)

  • 장경욱;김상진;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.248-252
    • /
    • 1995
  • In this paper, the samples are made by the new three-composition seed grain method, in order to obtain the low voltage varistor distributed randomly large seed grain in its bulk. The oscillation phenomena of carriers appeared from current-voltage characteristics under knee voltage is shown by the transient flow of non trapped carriers group in the trap level of intergranular layer, surface state and/or depletion layer. Current oscillation phenomena is hardly shown in the high electric field. The injected carriers from both electrodes are directly flowed from the conduction band of forward biased grain through the intergranular layer into the reverse biased grain, because the trap level in the electric field above the knee voltage is mostly filled.

  • PDF

Fabrication of Thick Periodically-poled Lithium Niobate Crystals by Standard Electric Field Poling and Direct Bonding

  • Kim, Byoung-Joo;Kim, Chung-Sik;Kim, Dong-Jin;Lim, Hwan-Hong;Park, Sung-Kyun;Cha, Myoung-Sik;Kim, Kyung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.420-423
    • /
    • 2010
  • We fabricated 1 mm-thick periodically-poled lithium niobate (PPLN) crystals by using a high-voltage amplifier for standard electric field poling combined with a voltage multiplier. Furthermore, two 1 mm-thick PPLNs were directly bonded to make a 2 mm-thick PPLN. The large aperture allowed broad angular tuning, and a broad spectral range of quasi-phase matched second-harmonic generation can be achieved in a single channel. High-power applications are also expected.

Numerical Study of Particle Collection and Entrainment in Electrostatic Precipitator (집진기내 입자 포집과 비산 문제에 대한 수치적 연구)

  • Kim, Ju-Hyeon;Kweon, Soon-Cheol;Kwon, Ki-Hwan;Lee, Sang-Hwan;Lee, Ju-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • A numerical simulation for particle collection efficiency in a wire-plate electrostatic precipitator (ESP) has been performed. Method of characteristics and finite differencing method (MOC-FDM) were employed to obtain electric field and space charge density, and lattice boltzmann method (LBM) was used to predict the Electrohydrodynamic (EHD) flow according to the ion convection. Large eddy simulation (LES) was considered for turbulent flow and particle simulation was performed by discrete element method (DEM) which considered field charging, electric force, drag force and wall-collision. One way coupling from FDM to LBM was used with small and low density particle assumption. When the charged particle collided with the collecting plate, particle-wall collision was calculated for re-entertainment effect and the effect of gravity force was considered.

A Development of Intelligent Electronic Device(IED) for Electric Power System applied embedded OS (임베디드 OS를 적용한 전력용 디지털 장치의 개발)

  • Oh, Jae-Hoon;Kwon, Hyo-Chul;Oh, Sung-Min;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.936-937
    • /
    • 2008
  • As a micro computer or micro processor technology has been advanced, the essential part which consists of electric power system has been changed into intelligent electronic device(IED), that is one kind of embedded system. There are already many parts changed into digital from analog in control and maintenance devices of electric system. These trends make advanced and novel concepts of devices and systems, that we couldn't even imagine in the analog circumstances. Now, the rate's of change is comparatively slower than IT field that is mainly represented by mobile communication, but that is a big change in the history of electric industries. Some people in those field called it Power-IT, and there have been many kinds of researches. Accelerated systems to go digital, users always and continuously demand more convenient, practical, and new functions. So, a lot of electric system manufactures have had tasks realizing many kinds of functions in an electronic device. According to the high-end technologies in semi-conductor and micro-computer field, manufactures can fully satisfy almost all of customer's needs, but there are other kinds of problems, such as large amount of program code, increasing complexity in proportion with program amount, and the hardness of maintenance and revision of the program. So nowadays, the necessity of embedded OS was emerged as a solution, and many researchers and manufactures have concentrated on studies related to embedded OS and its application.

  • PDF

Quench Behaviors of Superconducting YBCO film for Fault Current Limiters applying Protective Current Transformer (변류기(p-CT)를 적용한 YBCO 초전도 저항형 한류기의 ?치 특성)

  • 박권배;이방욱;강종성;오일성;현옥배
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.128-131
    • /
    • 2004
  • The resistive superconducting fault current limiters (SFCLs) are very attractive devices for the electric power network. But they have some serious problems when the YBCO thin films were used for the current limiting materials due to the in homogeneities caused by manufacturing process. When the YBCO films have some inhomogeneities, simultaneous quenches are difficult to achieve when the fault current limiting units are connected in series for increasing operating voltage ratings. Magnetic field application is one of the prospective way of inducing simultaneous quenches far the series-connected resistive FCL components. Magnetic field was typically generated by the fault current thorough a coil, which is connected to components of the fault current limiter in series, leaving the problem, which provides significant inductance to the power line and suppresses critical current density of the superconducting components. In this article we investigated the possible application of the protective current transformer (p-CT), which is available current source to the magnetic coil. This system inductively coupled to the circuit, therefore, remarkably reducing impedance to the circuit. The current by the protective current transformer was directly fed to the coil, generating magnetic field large enough to reduce critical current density of the components. This successfully induced simultaneous quenches of the series-connected resistive FCL components.

  • PDF

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

Development of a Large capacity Rectifier for using Full-Bridge Type (풀 브리지 방식을 이용한 대용량 정류기 구현)

  • Lee, Je-Min;Yun, Kyung-Sub;Lim, Sung-Woon;Kim, Woo-Hyun;Kwon, Woo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.277-279
    • /
    • 2005
  • Generally, It was used to use a unit of a Large regularity in developing Large Capacity Converter System of the electric power. Lager a capacity of a unit of regularity, more expensive cost of it. So, normally, We overcome the limit of a proper form of an electricity semiconductor which be used in application field of Large capacity electricity conversion system through the Composition of Multi-level Circuit or Dual-Mode or parallel switch. but some problem is discussed. Using parallel RC-diode circuit instead of Large Capacity diode, We implemented a circuit that it overcome the limit of a regularity with dealing current distributed by parallel RC-diode circuit.

  • PDF

Analysis on Solid Insulator Flashover Characteristics on Moisture Contamination for Electrical Insulation Improvement of ESS (ESS 안전성 개선을 위한 결로 운전 조건 고려 고체절연물 연면 절연파괴특성 분석)

  • Kim, Jin-Tae;Lee, Seung-Yong;Kim, Ji-young;Seok, Bok Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.317-321
    • /
    • 2021
  • As the large-scale renewable energy power plant increases, the high-capacity and compact Energy Storage System (ESS) is required. However, this trend could reduce the insulation reliability of ESS. In this study, the surface flashover characteristics for four types of solid insulators are investigated in the uniform electric field with AC and Lightning Impulse (LI) voltage waveforms under various contamination levels. In addtion, insulator surfaces are compared based on the contact angle before and after surface flashover. The experimental results show that AC flashover voltage is dependent on the materials and the contamination level, but LI flashover voltage is only associated with the contamination level. Especially, AC flashover voltage of PC (PolyCarbonate) is higher than that of other insulators, which is associated with the unique and sequential creepage discharge propagation pattern of PC. The localized discharges on the surface of PC form corresponding tracking points. Then, the interconnected trackings result in the complete flashover. This flashover patterns degrade the surface of PC much more than that of epoxy and Bulk Molding Compoud (BMC). Thus, the contact angle of PC is significantly reduced compared to that of other insulators. The increased hydrophilicity in the surface of PC enhances the insulator surface conductivity.