• Title/Summary/Keyword: large displacements

Search Result 321, Processing Time 0.025 seconds

A Study on the Displacement Measuring Method of High-rise Buildingas using LiDAR (라이다를 이용한 고층 건물의 변위 계측 기법에 관한 연구)

  • Lee Hong-Min;Park Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.151-158
    • /
    • 2006
  • Structural health monitoring is concerned with the safety and serviceability of the users of structures, especially for the case of building structures and infrastructures. When considering the safety of a structure, the maximum stress in a member due to live load, earthquake, wind, or other unexpected loadings must be checked not to exceed the stress specified in a code. It will not fail at yield, excessively large displacements will deteriorate the serviceability of a structure. To guarantee the safety and serviceability of structures, the maximum displacement in a structures must be monitored because actual displacement is a direct assessment index on its stiffness. However, no practical method has been reported to monitor the displacement, especially for the case of displacement of high-rise buildings because of not to easy accessive. In this paper, it is studied displacement measuring method of high-rise buildings using LiDAR The method is evaluated by analyzing accuracy of measured displacements for existing building.

  • PDF

Seismic Response of Base-Isolated Liquid Storage Tanks Considering Liquid-Structure-Soil Interaction (유체-구조물-지반 상호작용을 고려한 면진된 유체저장탱크의 3차원 지진응답)

  • 조성용;김문겸;임윤묵
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.98-105
    • /
    • 2002
  • The effects of the base-isolation system and elastic soil foundation on the behavior of a liquid storage tank are studied. To evaluate the seismic response of liquid storage tank accurately, the coupled dynamic system considering base isolation and soil interaction problem is formulated in time domain. Results show that the base isolation system reduces effectively the radial displacements, base shears, overturning moments, axial resultant stresses and the hydrodynamic pressure by providing flexibility and energy dissipation capability. Base Isolation may, however, increase the relative liquid sloshing amplitude due to the effect of liquid-structure interaction and cause excessive large relative displacements between structure and foundation. In addition to base-isolator, the dynamic behavior of liquid storage tank is related to the flexibility of base foundation, so the analysis of soil-structure interaction s achieved.

  • PDF

Subsidence Due to Groundwater Withdrawal in Kathmandu Basin Detected by Time-series PS-InSAR Analysis

  • Krishnan, P.V.Suresh;Kim, Duk-jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.703-708
    • /
    • 2018
  • In recent years, subsidence due to excessive groundwater withdrawal is a major problem in the Kathmandu Basin. In addition, on 25 April 2015, the basin experienced large crustal displacements caused by Mw 7.8 Gorkha earthquake. In this study, we applied StaMPS- Persistent Scatterer InSAR (StaMPS PS-InSAR) technique to estimate the spatio-temporal displacements in the basin after the mainshock. 34 Sentinel-1 C-band SAR data are used for measuring subsidence velocity during 2015-2017. We found the maximum subsidence velocity of about 9.02 cm/year and mean subsidence rate of about 8.06 cm/year in the line of sight direction, respectively, in the central part of the basin.

A multiplexed fiber-optic sensor for measuring large displacement (대변위 측정을 위한 다중화된 광섬유 센서)

  • Yoo, Jung-Ae;Kwon, Il-Bum;Jo, Jae-Heung;Seo, Dae-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.169-179
    • /
    • 2005
  • A multiplexed bend loss type single-mode fiber-optic sensor system was prepared to measure the displacement of several cm of the civil engineering structures such as many bridges, tunnels and various buildings. This bend loss type fiber-optic sensor used the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using OTDR (optical time domain reflectometer) for measuring displacements. And the experiments were conducted for showing the measurement feasibility on the range of 10 cm, and the multiplexing experiments were also performed to measure the displacements of 5 measuring positions of an object by setting these 5 fiber-optic sensors on a single mode fiber simultaneously.

Settlement of and load distribution in a granular piled raft

  • Madhav, Madhira R.;Sharma, J.K.;Sivakumar, V.
    • Geomechanics and Engineering
    • /
    • v.1 no.1
    • /
    • pp.97-112
    • /
    • 2009
  • The interactions between a granular pile and raft placed on top are investigated using the continuum approach. The compatibility of vertical and radial displacements along the pile - soil interface and of the vertical displacements along the raft - top of ground interfaces are satisfied. Results show that consideration of radial displacement compatibility does not influence the settlement response of or sharing of the applied load between the granular pile and the raft. The percentage load carried by the granular pile (GP) increases with the increase of its stiffness and decreases with the increase of the relative size of raft. The normal stresses at the raft - soil interface decrease with the increase of stiffness of GP and/or relative length of GP. The influences of GP stiffness and relative length of GP are found to be more for relatively large size of raft. The percentage of load transferred to the base of GP increases with the increase of relative size of raft.

Dynamic response of empty steel tanks with dome roof under vertical base motion

  • Virella, Juan C.;Godoy, Luis A.
    • Steel and Composite Structures
    • /
    • v.9 no.2
    • /
    • pp.119-130
    • /
    • 2009
  • This paper reports results of the structural response of empty steel tanks under vertical ground motions. The tanks are modeled using a finite element discretization using shell elements, and the vertical motion is applied and analyzed using nonlinear dynamics. Several excitation frequencies are considered, with emphasis on those that may lead to resonance of the roof. The computational results illustrate that as the base motion frequency is tuned with the frequency of the first roof-mode of the tank, the system displays large-amplitude displacements. For frequencies away from such mode, small amplitude displacements are obtained. The effect of the height of the cylinder on the dynamic response of the tank to vertical ground motion has also been investigated. The vertical acceleration of the ground motion that induces significant changes in the stiffness of the tank was found to be almost constant regardless of the height of the cylinder.

Behavior of wall panels in industrial buildings caused by differential settlements

  • Fernandez, Suyai;Jaca, Rossana C.;Godoy, Luis A.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.3
    • /
    • pp.443-460
    • /
    • 2015
  • This paper presents the analysis of mechanical behavior of metal wall panels of storehouses and industrial buildings subjected to differential settlements. The storehouses considered are representative of those used in the agricultural activity. A small-scale model was built and tested in order to have evidence of the behavior and to validate computational models. The numerical investigation is carried out through finite element analysis using a general-purpose software, by modeling buildings with different geometries and evaluating different settlements of the ground. To obtain an adequate model, geometric non-linearity has to be taken into account. Models that represent the most usual geometric typologies were investigated under support settlements. The deflected shape of the wall panel and the relationship between the horizontal displacements and the settlement of the foundations are evaluated. The results show that there are large out-of-plane displacements caused by settlements that would be admitted by design recommendations.

A study on the nonlinear analysis of spatial frame structures with nonlinear rotational spring elements (비선형 회전 스프링 요소를 갖는 공간 프레임의 구조의 비선형 해석에 관한 연구)

  • 이병채;박문식
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.29-42
    • /
    • 1990
  • Three dimensional frame structures with such nonlinearities as large displacements, medium rotations, plastic hinges and local defects are efficiently analyzed by introducing the nonlinear rotational spring. Formulations are based on the incremental updated Lagrangian descriptions and the virtual work principle, Axial displacement and twisted angle in beam elements are interpolated linearly, while bending displacements are approximated by the Hermite polynomials. The modified are length method is used as a solution method. The moment-angle of rotation relationship obtained analytically or experimentally can be easily incorporated into the solution procedure. Several examples tested show that the present method can be used efficiently in analyzing nonlinear frame structures with plastic hinges or local defect.

  • PDF

Measuring Method of In-plane Position Based On Reference Pattern (레퍼런스 패턴 기반 면내 위치 측정 방법)

  • Jung, Kwang Suk
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Generally, in-plane position of moving object is measured referring to the reference pattern attached to the object. From optical camera to magnetic reluctance probe, there are many ways detecting a variation of the periodical pattern. In this paper, the various operating principles developed for in-plane positioning are reviewed and compared each other. And, a novel method measuring large rotation as well as x, y linear displacements is suggested, including a detailed description of the overall system layout. It is a modified version of the surface encoder, which is a robust digital measuring method. From the surface encoder, the rotation of an object is measured indirectly through a compensated input of optical servo and independently of linear displacements. So, the operating range can be extended simply by enlarging the reference pattern, without magnifying the decoding units.

  • PDF

3D Finite Element Analysis of Fault Displacements in the Nobi Fault Zone, Japan

  • Choi, Young-Mook;Kim, Woo-Seok;Lee, Chul-Goo;Kim, Chang-Yong;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.323-332
    • /
    • 2014
  • The Nobi fault zone, which generated the 1891 Nobi Earthquake (M8.0), includes five or six faults distributed in and around Gifu and Aichi prefectures, Japan. Because large cities are located near the fault zone (e.g., Gifu and Nagoya), and because the zone will likely be reactivated in the future, relatively thorough surveys have been conducted on the 1891 Nobi earthquake event, examining the fault geometry, house collapse rate, and the magnitude and distribution of earthquake intensity and fault displacement. In this study, we calculated the earthquake slip along faults in the Nobi fault zone by applying a 3D numerical analysis. The analysis shows that a zone with slip displacements of up to 100 mm included all areas with house collapse rates of 100%. In addition, the maximum vertical displacement was approximately ${\pm}1700mm$, which is in agreement with the ${\pm}1400mm$ or greater vertical displacements obtained in previous studies. The analysis yielded a fault zone with slip displacements of > 30 mm that is coincident with areas in which house collapse rates were 60% of more. The analysis shows that the regional slip sense was coincident with areas of uplift and subsidence caused by the Nobi earthquake.