• Title/Summary/Keyword: landfill gas

Search Result 238, Processing Time 0.022 seconds

The Assessment for Environmental Stabilization in Open Dumping Landfill Site from Physical Composition and Gas Analysis - A Case Study of Noeun Landfill - (비위생 매립지의 물리적 조성 및 가스 분석을 통한 안정화 평가 - 노은 매립지 사례 연구 -)

  • Lee, Min-Hee;Jang, Byoung-In;Yun, Cheol;Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.27-35
    • /
    • 2005
  • A case study of the assessment for environmental stabilization in open dumping landfill site was carried out physical composition, total solid, moisture, and landfill gas(LFG) analysis in landfill site. The result of physical ratio were represented combustibles 23.64% and incombustibles 76.36%, TS 77.69%, VS 74.24%, FS 25.75%. The biodegradable organic matters were almost degraded and the result of the landfill gas showed that the $CH_4$ gas were measured as 4.5%. As the result of the assessment on the open dumping landfill it appears that this landfill is stabled for the maturation phase and formation $CO_2$ concentration lower than 15%.

  • PDF

Economic Analysis of Landfill Gas Recycling Considering Environmental Benefit (환경편익을 고려한 매립가스 자원화 사업의 경제성분석)

  • Kim, Young-Jun;Lee, Jong-Yeon;Koo, June-Mo;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.181-188
    • /
    • 2010
  • The objectives of this study are to analyze the possibility of the landfill gas recycling for the middle and small scale landfills where the recycling facilities are not installed in Korea. It was found that the power generation plants by landfill gas were installed in domestic 15 landfills and the gas engine generation was adopted in 14 places. As the result of economic analysis, the landfill gas recycling is found to be available in 12 places and CERs of 153,693 $tCO_{2e}$ can be secured per year. Through the reduction of the air pollutants and VOCs, the social benefits of 730 million won accrue per year. Also, the power production of 18.8 GWh will substitute the crude oil imports of 4,048 TOE and the revenue of 2.49 billion won is expected to power trading. It is also found that the power generation plants by landfill gas will give the social benefits such as the reduction of the environmental problems and the substitution effect of crude oil imports.

An Estimation Method of Organic Matter Content Ratio for the Termination of Post-closure Maintenance of a Landfill (매립장 사후관리종료를 위한 유기물 함량비 산정방법)

  • Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.4
    • /
    • pp.11-19
    • /
    • 2019
  • This paper examines an assessment method for terminating the post-closure maintenance of a landfill using a simplified landfill gas model. The case study site is the Sudokwon Landfill in Incheon city, which was closed in 2000. The deviations of the results obtained by the regular model and the simplified model were both slightly over 10% from the measured data. Also, the deviation of the simplified model from the regular model has been less than 5% since 2005. Thus, the simplified model could be applied to other landfills that have been closed for at least 5 years. Additionally, the results of the mass balance analysis using the simplified landfill gas model indicated that 39% of the organic carbon was discharged, leading to organic carbon and organic matter content of 7.2 and 17.6%, respectively, in the landfill by the end of 2018.

Long Term Affecting Factors on Major Water Quality Items of Landfill Leachate (매립장 침출수 주요 수질항목에 대한 장기 영향요소)

  • Chun, Seung-Kyu;Kim, Min Hyuk;Won, Jong Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.24-33
    • /
    • 2021
  • Analysis of long term affecting factors on water quality items of gas emission form (BOD, COD) and leachate emission form (T-N, non-bio-degradable COD (NBDCOD)) was performed for the SUDOKWON 1st Landfill Site (LS1) and 2nd Landfill Site (LS2). As landfill gas was generated, BOD and COD decreased from 6,887 and 20,025 mg/L in 1993 to 49.5 and 670.2 mg/L in 2019, respectively. TN and NBDCOD increased with waste decomposition but gradually decreased after landfill closure because of the precipitation infiltration effect. Due to the drastic decline of carbon in the leachate, the BOD/TN ratios of LS1 and LS2 declined from 13.0 and 17.0 during early stage of the landfill to 0.07 and 0.16 in 2019, respectively; LS2 and NBDCOD/COD increased from 0.25 to 0.65 during the same period. These conditions caused carbon deficiency in denitrification treatment and a chemical post-treatment request for NBDCOD. The different behaviors of gas emission and leachate emission items suggest the necessity of different strategic approaches in the long term perspective.

HYLGS 모델을 활용한 수도권 매립지에서의 침출수-가스의 동시유동 해석에 관한 연구

  • 이광희;박용찬;성원모
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.225-231
    • /
    • 1998
  • Open dump causes groundwater and soil contamination by leachate, air pollution by LFG (Landfill Gas). In this paper, in order to improve landfill researches which have been done about reduction of high leachate level and LFG collection in the Kimpo landfill separately, the effect of simultaneous flowing of leachate and LFG has been Studied. The HYLGS (Hanyang Leachate Gas Simulator) used in this study is a 3D, 2-phase, transient FDM model which can be applied to venting trenches in a landfill. From present numerical analysis it can be concluded that all the pressures of the Kimpo landfill grid system are almost the same and their maximum value in the center grid block of the system is approximately 26 m $H_2O$ (2.52 atm), that because the pressures of venting trench layer situated in the middle of the landfill have the lowest values and equal with air pressure, the venting trenches play an important role in landfill stabilization, that the flow of gas will be more difficult as time goes by owing to the increase of LGR(Leachate and gas ratio).

  • PDF

Stabilization of Industrial Wastes Landfill using Lab-lysimeter (모형매립조를 이용한 산업폐기물 매립지의 안정화 조사 기초 연구)

  • 박동일;최석규;홍종순;장인용
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.9-18
    • /
    • 1998
  • An experimental research was conducted to establish primary data for the stabilization assessment of industrial wastes landfill with analysis of waste components and investigation of leachate and gas generation, using three sets of lysimeter as experimental apparatus. Comparing results of lysimeter from data of landfill, it is suggested that lysimeter of this study can be used to accomplish the stabilization assessment of the real landfill site. Moisture content was lower as landfill period was older and combustible component was the highest in lysimeter C. The C/N ratio of waste was 7.4~14.4 and, with the elemental analysis, the theoretical gas generation rate based on the modified Buswell equation was 0.47~0.49 $m^3/kg-dry$ waste in lysimeter C. Considering the C/N ratio of leachate, it is concluded that the addition of carbon source is needed to biodegrade leachate hereafter. Gas generation rate($m^3/kg-dry$ waste) from lysimeter A, B and C was 0.0009, 0.014 and 0.0067, respectively, and different from each other according to the landfill period of wastes. The results in this study show that the biodegradation of microorganism for stabilization of landfill was inhibited and more activated in acidogenic step than in methanogenic of anaerobic degradation.

  • PDF

Evolution of Sudokwon Landfill: from Waste Containment to Energy Generation

  • Chung, Moon-Kyung;Kim, Yun-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.186-193
    • /
    • 2009
  • Since its opening in 1992, Sudokwon Landfill has become a landfill in which wastes generated from more than 22 million people are treated and disposed of. Its first phase landfill was closed in 2000 and the second phase landfill is in operation since then. The Korean environmental policies on refuse have drastically evolved for the last decade or so. From merely safe containment of wastes, the utilization of them as a source for energy generation and the minimization of waste volume to be filled in landfills are in the mainstream. Keeping in pace with the new trends, several challenging projects are in their way to blossom in Sudokwon Landfill. This paper briefs some important activities in the landfill. They are (1) geotechnical issues related to the construction and maintenance of the $1^{st}$ and $2^{nd}$ Landfills and (2) landfill gas and bioreactor which are recently emerging in the market.

  • PDF

Minimizing the Measurement Error from Gas Compositions of Gas Vent in Sanitary Landfill (쓰레기 매립지 가스 포집관에서 가스조성에 따른 계측오차의 최소화)

  • 이해승;이문형
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2002
  • A methods of minimizing the measurement error brought from gas compositions was proposed by Hot wire Anemometer which don't have measurement resistance to calculate of gas vent in sanitary landfill. It was determined measurement error to compared velocity at the center of pipe to calculate using rotor meter and density gas compositions with velocity at the center of pipe to calculate using water head indicator which don't have measurement resistance. Considering the methods of minimizing gas velocity in sanitary landfill using hot wire anemometer and rotor meter, it was found to minimize within 10% as error of gas vent in sanitary landfill.

Conformity Enhancement of Methane Generation Model for In-Service Landfill Site (운영 중인 매립장에서의 메탄가스 발생 모델의 정합도 향상)

  • Chun, Seung-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.213-223
    • /
    • 2016
  • The validity of landfill gas models is an important problem considering that they are frequently used for landfill-site-related policy making and energy recovery planning. In this study, the Monte Carlo method was applied to an landfill gas generation model in order to enhance conformity. Results show that the relative mean deviation between measured data and modeled results (MD) decreased from 19.8% to 11.7% after applying the uncertainty range of Intergovernmental Panel on Climate Change (IPCC) to the methane-generation potential and reaction constants. Additionally, when let reaction constant adjust derived errors from all other modeling components, such as model logic, gauging waste, and measured methane data, MD decreased to 6.6% and the disparity in total methane generation quantity to 2.1%.

Measurements and Calculation of Injection Mass Rate of LFG for Intake Injection in Spark Ignition Engines (불꽃점화 엔진의 흡기관 분사를 위한 매립지가스 분사량의 측정 및 계산)

  • Kim, Kyoungsu;Choi, Kyungho;Jeon, Wonil;Kim, Bada;Lee, Daeyup
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.36-42
    • /
    • 2021
  • When the landfill gas generated at the landfill site is released into the atmosphere, methane gas with a high global warming potential is emitted, which adversely affects climate change. When methane contained in landfill gas is used as fuel for internal combustion engines and burned to generate electricity, it is emitted into the atmosphere in the form of carbon dioxide, which can contribute to lowering the global warming potential. Therefore, in order to use the landfill gas as fuel for power generation using an internal combustion engine, it is important to increase the thermal efficiency of the engine. Thus, it is necessary to use a fuel supply system in which gas is injected using an electronically controlled injector at an intake port for each cylinder rather than a fuel supply technology using the conventional mixer technology. In order to use the electronically controlled gas injection method, it is important to accurately measure the mass flow rate according to the conditions of using landfill gas. For this, a study was conducted to measure the injection amount and calculate them in order for the intake port gas injection of landfill gas.