• Title/Summary/Keyword: laminar flow

Search Result 936, Processing Time 0.023 seconds

Design of Chamber in Continuous Furnace for Uniform Temperature Distribution (균일 온도를 유지하는 연속 소성로 체임버의 설계)

  • Lee, Kwangju;Choi, Joon Hyeok;Jang, Han Seul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5344-5351
    • /
    • 2013
  • Chambers in a continuous furnace were designed. A chamber consists of inlets and outlets of nitrogen gas which is used to discharge burned gas and heating pipes (HP) which are used to keep temperature of fired materials at $1,300^{\circ}C$. Design variables were numbers of inlets and outlets, distance between floor and lower HP ($h_1$), distance between lower HP and fired materials ($h_2$), distance between fired materials and upper HP ($h_3$), temperature of HP, numbers of HP and distance between HP. The numbers of inlets and outlets were determined so that nitrogen gas formed a laminar flow for efficient discharge. All other design variables were determined so that temperature of fired materials is as uniform as possible near $1,300^{\circ}C$. Chambers were produced and temperature was measured at 21 points using thermocouples. The largest deviation from $1,300^{\circ}C$ was less than ${\pm}2.2^{\circ}C$.

Influence of the Geometry on the Natural Convection Heat Transfer inside a Vertical Cylinder (수직 원형관내 자연대류 열전달에서 기하구조의 영향)

  • Ohk, Seung-Min;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.97-103
    • /
    • 2015
  • Natural convection heat transfer rates in vertical pipes were measured varying the diameter, length, and roughness of vertical cylinder. To achieve high Rayleigh number with relatively small test rig, mass transfer experiments instead of heat transfer were performed based on the analogy. Prandtl number was 2,014. The length of vertical cylinder was 0.1m, 0.3m, and 0.5m, which correspond to GrL $4.2{\times}10^7$, $1.1{\times}10^9$, and $5.5{\times}10^9$. To each length of vertical cylinder, the heat transfer rates were measured varying the iameter 0.005m, 0.01m, and 0.03m. The heat transfer rate for a short length pipe(0.1m) agreed with the prediction from Le Fevre correlation developed for a vertical plate for all diameter. The heat transfer rate decreases as the diameter and the length of the pipe increases. The heat transfer rate inside of vertical cylinder is affected by roughness only for a laminar flow regime.

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

Combustion Characteristic Study of LNG Flame in an Oxygen Enriched Environment (산소부화 조건에 따른 LNG 연소특성 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Lee, Dae-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • The ultimate objective of this study is to develop oxygen-enriched combustion techniques applicable to the system of practical industrial boiler. To this end the combustion characteristics of lab-scale LNG combustor were investigated as a first step using the method of numerical simulation by analyzing the flame characteristics and pollutant emission behaviour as a function of oxygen enrichment level. Several useful conclusions could be drawn based on this study. First of all, the increase of oxygen enrichment level instead of air caused long and thin flame called laminar flame feature. This was in good agreement with experimental results appeared in open literature and explained by the effect of the decrease of turbulent mixing due to the decrease of absolute amount of oxidizer flow rate by the absence of the nitrogen species. Further, as expected, oxygen enrichment increased the flame temperatures to a significant level together with concentrations of $CO_2$ and $H_2O$ species because of the elimination of the heat sink and dilution effects by the presence of $N_2$ inert gas. However, the increased flame temperature with $O_2$ enriched air showed the high possibility of the generation of thermal $NO_x$ if nitrogen species were present. In order to remedy the problem caused by the oxygen-enriched combustion, the appropriate amount of recirculation $CO_2$ gas was desirable to enhance the turbulent mixing and thereby flame stability and further optimum determination of operational conditions were necessary. For example, the adjustment of burner with swirl angle of $30\sim45^{\circ}$ increased the combustion efficiency of LNG fuel and simultaneously dropped the $NO_x$ formation.

Conversion of Total Atrio-pulmonary Connection to Total Cavo-pulmonary Connection - Review of Indications and Hemodynamic Characteristics - (심방-폐동맥 문합술 후 총 체정맥-폐동맥 문합술로의 전환 - 수술 적응증 및 혈역학적 특징의 검토 -)

  • Seo, Jung Ho;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.199-207
    • /
    • 2002
  • Purpose : Since the successful application of total atrio-pulmonary connection(TAPC) to patients with various types of physiologic single ventricles in 1971, post-operative survival rates have reached more than 90%. However some patients have been shown to present with late complications such as right atrial thrombosis, atrial fibrillation and protein losing enteropathy eventually leading to re-operation to control the long-term complications. The aim of this study is to review the results of total cavo-pulmonary connection(TCPC) in cases with late complications after TAPC. Methods : Between Jan. 1995 and Dec. 2000, 6 patients(5 males and 1 female) underwent cardiac catheterization $11{\pm}3$ months after conversion of previous TAPC to TCPC. We compared the hemodynamic and morphologic parameters before and after TCPC and also assessed the clinical outcomes. The indications for TAPC were tricuspid atresia in 4 cases and complex double-outlet right ventricle with single ventricle physiology in 2 cases. Results : There was no peri-operative mortality and all patients were clinically and hemodynamically improved at a mean follow-up of 11 months(range : 4 to 13). However, protein losing enteropathy recurred in 2 patients; this was were successfully treated with subcutaneous administration of heparin. Right atrial pressure before TCPC was $18.0{\pm}3.6mmHg$, but baffle pressure, corresponding to right atrial pressure decreased to $14.8{\pm}3.6mmHg$ after TCPC. The size of the pulmonary arteries did not regress after TCPC. Conclusion : The conversion of TAPC to TCPC improves clinical and hemodynamic status by decreasing the right atrial pressure and by providing a laminar cavo-pulmonary flow which enhances the effective pulmonary circulation in the so-called Fontan circulation.

Characteristic Study of LNG Combustion in the mixture of $O_2/CO_2$ ($O_2/CO_2$ 혼합조건에 따른 LNG 연소특성해석)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Lee, Dae-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.647-653
    • /
    • 2007
  • The ultimate objective of this study is to develop a reliable oxygen-enriched combustion techniques especially for the case of the flue gas recycling in order to reduce the $CO_2$ emissions from practical industrial boilers. To this end a systematic numerical investigation has been performed, as a first step, for the resolution of the combusting flame characteristics of lab-scale LNG combustor. One of the important parameters considered in this study is the level of flue gas recycling calculated in oxygen enriched environment. As a summary of flame characteristics, for the condition of 100% pure $O_2$ as oxidizer without any flue gas recycling, the flame appears as long and thin laminar-like shape with relatively high flame temperature. The feature of high peak of flame temperature is explained by the absence of dilution and heat loss effects due to the presence of $N_2$ inert gas. The same reasoning is also applicable to the laminarized thin flame one, which is attributed to the decrease of the turbulent mixing. These results are physically acceptable and consistent and further generally in good agreement with experimental results appeared in open literature. As the level of $CO_2$ recycling increases in the mixture of $O_2/CO_2$, the peak flame temperature moves near the burner region due to the enhanced turbulent mixing by the increased amount of flow rate of oxidizer stream. However, as might be expected, the flue gas temperature decreases due to presence of $CO_2$ gas together with the inherent feature of large specific heat of this gas. If the recycling ratio more than 80%, gas temperatures drop so significantly that a steady combustion flame can no longer sustain within the furnace. However, combustion in the condition of 30% $O_2/70% $ $CO_2$ can produce similar gas temperature profiles to those of conventional combustion in air oxidizer. An indepth analyses have been made for the change of flame characteristics in the aspect of turbulent intensity and heat balance.