• 제목/요약/키워드: lab testing

검색결과 354건 처리시간 0.025초

LabVIEW를 이용한 Exciter 가진시험 모듈 개발 (Developing the Excitation Testing Module with LabVIEW)

  • 최기수;정의봉;원성규;안세진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.37-41
    • /
    • 2007
  • Fast Fourier Transformation(FFT) is one of the most useful way to analyze response signal for the purpose of grasping the dynamic characteristics of system. Excitation is a factor or process making noise or vibration. It's typical and simple experimental method widely used for catching hold of dynamic peculiar characters and modal behaviors of system by frequency analysis. There are harmonic excitation, impact excitation, random excitation, sweep excitation, chirp excitation and so on as the ideal method in an experiment using exciter. In this thesis, excitation testing module for NI-PXI equipment is developed. The analyzing module is developed with LabVIEW tool. A user can generate each waveform for shaking a structure and see quickly and easily modal shape of system with this module. This developed module will be expected to build up more convenient and serviceable measurement system.

  • PDF

The effects of circadian disturbances induced by night shifts on the mouse peripheral tissues

  • Seo, Dong-Hyun;Kim, Han-Sung;Ko, Chang-Yong;Schreiber, Jurgen;Jang, Yeong-Su;Bae, Kiho
    • Animal cells and systems
    • /
    • 제16권5호
    • /
    • pp.357-365
    • /
    • 2012
  • We have examined the effect of circadian disturbances induced by night shifts (NSs) on the phenotypes of the tibiae and abdominal adipose tissues (ADTs) in a mouse model by using in vivo micro-computed tomography (micro-CT). We found that the volumes of total and visceral ADTs in the night-shifted group of mice were significantly larger (69 and 92%, respectively) than those in the control. The mean polar moment of inertia, cross-sectional thickness, and bone mineral density of the cortical bone in the night-shifted group of mice were less (13, 5, and 3%, respectively) than those in the control. Moreover, the volume and the thickness of growth plates (GPs) of the tibiae in the night-shifted mice were significantly smaller (22 and 20%, respectively) than those in the control. Taken together, our results indicate that disturbances in the mouse circadian rhythms induced by NSs affect the morphological characteristics of cortical bone, the volume and the thickness of GPs, and the volume of ADTs.

Transverse Wave Propagation in [ab0] Direction of Silicon Single Crystal

  • Yun, Sangjin;Kim, Hye-Jeong;Kwon, Seho;Kim, Young H.
    • 비파괴검사학회지
    • /
    • 제35권6호
    • /
    • pp.381-388
    • /
    • 2015
  • The speed and oscillation directions of elastic waves propagating in the [ab0] direction of a silicon single crystal were obtained by solving Christoffel's equation. It was found that the quasi waves propagate in the off-principal axis, and hence, the directions of the phase and group velocities are not the same. The maximum deviation of the two directions was $7.2^{\circ}$. Two modes of the pure transverse waves propagate in the [110] direction with different speeds, and hence, two peaks were observed in the pulse echo signal. The amplitude ratio of the two peaks was dependent on the initial oscillating direction of the incident wave. The pure and quasi-transverse waves propagate in the [210] direction, and the oscillation directions of these waves are perpendicular to each other. The skewing angle of the quasi wave was calculated as $7.14^{\circ}$, and it was measured as $9.76^{\circ}$. The amplitude decomposition in the [210] direction was similar to that in the [110] direction, since the oscillation directions of these waves are perpendicular to each other. These results offer useful information in measuring the crystal orientation of the silicon single crystal.

Experimental investigation on multi-mode vortex-induced vibration control of stay cable installed with pounding tuned mass dampers

  • Liu, Min;Yang, Wenhan;Chen, Wenli;Li, Hui
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.579-587
    • /
    • 2019
  • In this paper, pounding tuned mass dampers (PTMDs) were designed to mitigate the multi-mode vortex-induced vibration (VIV) of stay cable utilizing the viscous-elastic material's energy-dissipated ability. The PTMD device consists of a cantilever metal rod beam, a metal mass block and a specially designed damping element covered with viscous-elastic material layer. Wind-tunnel experiment on VIV of stay cable model was set up to validate the effectiveness of the PTMD on multi-mode VIV mitigation of stay cable. By analyzing and comparing testing results of all testing cases, it could be verified that the PTMD with viscous-elastic pounding boundary can obviously mitigate the VIV amplitude of the stay cable. Moreover, the installed location and the design parameters of the PTMD device based on the controlled modes of the primary stay cable, would have a certain extent suppression on the other modal vibration of the stay cable, which means that the designed PTMDs are effective among a large band of frequency for the multi-mode VIV control of the stay cable.

Performances of Point-of-care Testing Systems for HDL Cholesterol

  • Chae, Woo-Churl;Cho, Jeoung-Hwan;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.201-204
    • /
    • 2003
  • Plasma lipoproteins transporting cholesterol through blood vessels are divided into three major classes, VLDL, LDL, and HDL. The ratio of HDL cholesterol over the total can be used as an indicator for prognosis of coronary artery diseases. In this study, we have developed two analytical systems for %HDL cholesterol with different flow modes toward gravity and analyzed them for their characteristics and performances.

  • PDF

분리된 6.6kV급 고정자 권선의 부분방전 측정을 위한 Spiral 패치 안테나 센서 적용 연구 (Dismantled PD diagnosis on 6.6kV Stator Winding by Using Spiral Patch Antenna Sensor)

  • 키아우소 륀;신동훈;임광진;양훈;공태식;김희동;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.211-212
    • /
    • 2007
  • There have three kinds of partial discharge diagnosis testing: online, offline and dismantled testing on high voltage rotating machine. Our lab testing is dismantled testing, taking off pieces into individual parts of stator coil of high voltage rotating machine in laboratory. We investigate internal discharge, slot discharge, corona discharge and normal state on pre-made stator winding by using spiral patch antenna sensor. In this lab test we compare the experimental results of our spiral patch antenna sensor and reference commercial HFCT sensor.

  • PDF

대전력시험에서 고전압 측정시스템의 불확도 평가 (The estimation of uncertainty in high-voltage measuring system used in high-power tests)

  • 서윤택;김맹현;김대원;정주영;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.348-350
    • /
    • 2002
  • In the high-power tests to be performed on electrical apparatus as switchgears, transformers, insulators, cable and so on the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper introduces factors of uncertainty and describes estimation of uncertainty in high-voltage measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

Magnetic Bead-Based Immunoassay on a Microfluidic Lab-on-a-Chip

  • Park, Jin-Woo;Chong H. Ahn
    • 전자공학회지
    • /
    • 제29권3호
    • /
    • pp.41-48
    • /
    • 2002
  • This paper presents a basic concept of lab-on-a-chip systems and their advantages in chemical and biological analyses. In addition, magnetic bead-based immunoassay on a microfluidic system is also presented as a typical example of lab-on-chip systems. Rapid and low volume immunoassays have been successfully achieved on the demonstrated lab-on-a-chip using magnetic beads, which are used as both immobilization surfaces and bio-molecule carriers. Total time required for an immunoassay was less than 20 minutes including sample incubation time, and sample volume wasted was less than $50{\mu}l$ during five repeated assays. Lab-on-a-chip is becoming a revolutionary tool for many different applications in chemical and biological analysis due to its fascinating advantages (fast and low cost) over conventional chemical or biological laboratories. Furthermore, simplicity of lab-on-a-chip systems will enable self-testing capability for patients or health consumers overcoming space limitation.

  • PDF

비접촉식 초음파탐상방법 자동화 기술 (Automatic Noncontact Ultrasonic Inspection Technique)

  • 김영길;안봉영;이승석
    • 비파괴검사학회지
    • /
    • 제13권4호
    • /
    • pp.25-31
    • /
    • 1994
  • 비접촉으로 초음파를 송 수신하며 비파괴검사를 수행하는 EMAT(Electromagnetic Acoustic Transducer)를 이용한 초음파탐상장치를 구성하였고, 이를 3축 구동장치 및 데이타 수집, 처리장치와 연결하여 자동화를 시도하였다. 자동화에 적합하도록 송 수신이 한 몸체로 되어 있으며 인가하는 구동신호의 주파수를 변화시킴으로써 main beam의 방향을 조절할 수 있는 EMAT를 설계 제작하였으며, 제작된 EMAT의 특성을 측정하였다. EMAT를 이용한 초음파탐상장치, 3축 구동장치, 데이타 수집장치들에 대한 제어 및 데이타 처리를 위한 프로그램을 개발하였다. Host로 IBM-PC/AT 급을 사용하였으며, 컴퓨터 화면상에서 실재 장비를 가상적으로 구현하는 기법을 사용하였다. 제작된 전 탐상장치의 성능 분석과 결함 검출 능력을 평가하기 위하여, 인위적으로 결함을 가공한 시험편과 실재 결함이 내재되어있는 용접부에 대한 결함 검출을 시도하였으며, 만족할 만한 측정 결과를 화상으로 얻었다.

  • PDF

전력용 변압기 보호를 위한 통합보호제어장치의 하드웨어 설계와 실시간 성능 시험 (Real-time Testing and Hardware Design of Intelligent Electronic Device for Power Transformer Protection)

  • 박철원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.122-127
    • /
    • 2005
  • This paper proposes a prototype IED hardware design and it's real-time experimental results. To evaluate performance of the IED, the study is well constructed power system model including power transformer utilizing the EMTP software and the testing is made through simulation of various cases. The relaying that is well constructed using DSP chip and RISC CPU etc. has been developed and the prototype IED has been verified through on-line testing by LabVIEW simulator. The results show that an advanced relaying based prototype IED never mis-operated.

  • PDF