• Title/Summary/Keyword: lR Curve

Search Result 328, Processing Time 0.032 seconds

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Combination of 18F-Fluorodeoxyglucose PET/CT Radiomics and Clinical Features for Predicting Epidermal Growth Factor Receptor Mutations in Lung Adenocarcinoma

  • Shen Li;Yadi Li;Min Zhao;Pengyuan Wang;Jun Xin
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.921-930
    • /
    • 2022
  • Objective: To identify epidermal growth factor receptor (EGFR) mutations in lung adenocarcinoma based on 18F-fluorodeoxyglucose (FDG) PET/CT radiomics and clinical features and to distinguish EGFR exon 19 deletion (19 del) and exon 21 L858R missense (21 L858R) mutations using FDG PET/CT radiomics. Materials and Methods: We retrospectively analyzed 179 patients with lung adenocarcinoma. They were randomly assigned to training (n = 125) and testing (n = 54) cohorts in a 7:3 ratio. A total of 2632 radiomics features were extracted from the tumor region of interest from the PET (1316) and CT (1316) images. Six PET/CT radiomics features that remained after the feature selection step were used to calculate the radiomics model score (rad-score). Subsequently, a combined clinical and radiomics model was constructed based on sex, smoking history, tumor diameter, and rad-score. The performance of the combined model in identifying EGFR mutations was assessed using a receiver operating characteristic (ROC) curve. Furthermore, in a subsample of 99 patients, a PET/CT radiomics model for distinguishing 19 del and 21 L858R EGFR mutational subtypes was established, and its performance was evaluated. Results: The area under the ROC curve (AUROC) and accuracy of the combined clinical and PET/CT radiomics models were 0.882 and 81.6%, respectively, in the training cohort and 0.837 and 74.1%, respectively, in the testing cohort. The AUROC and accuracy of the radiomics model for distinguishing between 19 del and 21 L858R EGFR mutational subtypes were 0.708 and 66.7%, respectively, in the training cohort and 0.652 and 56.7%, respectively, in the testing cohort. Conclusion: The combined clinical and PET/CT radiomics model could identify the EGFR mutational status in lung adenocarcinoma with moderate accuracy. However, distinguishing between EGFR 19 del and 21 L858R mutational subtypes was more challenging using PET/CT radiomics.

A Study on the Fracture Resistance Curve and Effect of Side Grooves of SG365 Material (SG365강의 파괴저항곡선과 측면홈효과에 관한 연구)

  • 임만배
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.14-21
    • /
    • 2001
  • SG-365 steel is an important material End used for manufacturing a pressure vessel and gas piping. In this investigation, the elastic plastic fracture toughness of this material is evaluated by the unloading compliance method according to the ASTM E8l3-97 and E1152-97 method on the smooth and side groove In specimens. The effect of smooth and side groove is studied on the elastic plastic fracture toughness. The side grooved specimen is very useful in estimation of the $J_{IC}$. Because it is much easier than the smooth specimen to the onset of the ductile tearing by the R curve method. Besides. it improves the accuracy of toughness values, decreases the scattering of them and crack tunneling effect and shear lip by the side groove.

  • PDF

Gadolinium Complex of 1,4,7,10-Tetraazacyclododecane-1,4,7-trisacetic acid (DO3A) Conjugate of [(p-aniline benzothiazole)methyl]pyridine as a Tumor-Targeting MRI Contrast Agent

  • Nam, Ki Soo;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3654-3658
    • /
    • 2013
  • The synthesis of a DO3A conjugate of [(p-aniline benzothiazole)methyl]pyridine ($L^2H_3$) and its gadolinium complex of the type [$Gd(L^2)(H_2O)$] ($GdL^2$) is described. The $R_1$ relaxivity ($=4.50mM^{-1}sec^{-1}$) and kinetic inertness of $GdL^2$ compares well with those of structurally analogous Dotarem$^{(R)}$ ($R_1=3.70mM^{-1}sec^{-1}$), a typical extracellular (ECF) MRI contrast agent (CA). Yet, by comparison with Dotarem$^{(R)}$, $GdL^2$ exhibits non-covalent interactions with human serum albumin (HSA) as evidenced by the ${\varepsilon}^*$ titration curve along with in vivo MR signal enhancement in both aorta and heart. Liver-specific nature of $GdL^2$ is also observed as excretion is made through gallbladder. Most notably, $GdL^2$ further demonstrates specificity toward the MDA-MB-231 breast cancer.

Dependence of Self-heating Effect on Width/Length Dimension in p-type Polycrystalline Silicon Thin Film Transistors

  • Lee, Seok-Woo;Kim, Young-Joo;Park, Soo-Jeong;Kang, Ho-Chul;Kim, Chang-Yeon;Kim, Chang-Dong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.505-508
    • /
    • 2006
  • Self-heating induced device degradation and its width/length (W/L) dimension dependence were studied in p-type polycrystalline silicon (poly-Si) thin film transistors (TFTs). Negative channel conductance was observed under high power region of output curve, which was mainly caused by hole trapping into gate oxide and also by trap state generation by self-heating effect. Self-heating effect became aggravated as W/L ratio was increased, which was understood by the differences in heat dissipation capability. By reducing applied power density normalized to TFT area, self-heating induced degradation could be reduced.

  • PDF

Estimation of Early Growth and Spawning Period of Marbled Flounder (Pseudopleuronectes yokohamae) in the Water off Namhae of Korea as Indicated from Daily Growth Increments in Otoliths (문치가자미(Pseudopleuronectes yokohamae) 치어의 이석 일륜을 이용한 성장 및 산란시기 추정)

  • Joo, Hyeong-Woon;Gwak, Woo-Seok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Hatching date, main spawning period and growth of juvenile marbled flounder (Pseudopleuronectes yokohamae) were determined by analysis of microstructure in otoliths. Marbled flounders were collected by a small beam trawl in Namhae from February 2011 to January 2012. The length (L, mm) was related to body weight (W, g); $W=9.76^*10^{-8}L^{4.39}$ ($r^2=0.93$). The length was also related to otolith radius (R, ${\mu}m$); L=0.0795R+0.2249 ($r^2=0.92$). The growth in length was represented by Gompertz growth curve; $L_t=135{\exp}\{-{\exp}[0.0103(t-116)]\}$ ($r^2=0.83$). The hatching date calculated from the number of daily growth increments in otoliths was between mid-December and mid-February.

Effects of gut microbiota on the pharmacokinetics of protopanaxadiol ginsenosides Rd, Rg3, F2, and compound K in healthy volunteers treated orally with red ginseng

  • Kim, Jeon-Kyung;Choi, Min Sun;Jeung, Woonhee;Ra, Jehyeon;Yoo, Hye Hyun;Kim, Dong-Hyun
    • Journal of Ginseng Research
    • /
    • v.44 no.4
    • /
    • pp.611-618
    • /
    • 2020
  • Background: It is well recognized that gut microbiota is involved in the biotransformation of ginsenosides by converting the polar ginsenosides to nonpolar bioactive ginsenosides. However, the roles of the gut microbiota on the pharmacokinetics of ginsenosides in humans have not yet been fully elucidated. Methods: Red ginseng (RG) or fermented red ginseng was orally administered to 34 healthy Korean volunteers, and the serum concentrations of the ginsenosides were determined using liquid chromatography-tandem mass spectrometry. In addition, the fecal ginsenoside Rd- and compound K (CK)eforming activities were measured. Then, the correlations between the pharmacokinetic profiles of the ginsenosides and the fecal ginsenoside-metabolizing activities were investigated. Results: For the RG group, the area under the serum concentratione-time curve values of ginsenosides Rd, F2, Rg3, and CK were 8.20 ± 11.95 ng·h/mL, 4.54 ± 3.70 ng·h/mL, 36.40 ± 19.68 ng·h/mL, and 40.30 ± 29.83 ng·h/mL, respectively. For the fermented red ginseng group, the the area under curve from zero to infinity (AUC) values of ginsenosides Rd, F2, Rg3, and CK were 187.90 ± 95.87 ng·h/mL, 30.24 ± 41.87 ng·h/mL, 28.68 ± 14.27 ng·h/mL, and 137.01 ± 96.16 ng·h/mL, respectively. The fecal CK-forming activities of the healthy volunteers were generally proportional to their ginsenoside Rd-eforming activities. The area under the serum concentration-time curve value of CK exhibited an obvious positive correlation (r = 0.566, p < 0.01) with the fecal CK-forming activity. Conclusion: The gut microbiota may play an important role in the bioavailability of the nonpolar RG ginsenosides by affecting the biotransformation of the ginsenosides.

Studies on Efficient Plowing Methods and the Shapes of Field for 4 Wheel Tractor (사수트렉터를 위한 효율적인 정기방법과 포장형상에 관한 연구)

  • 원장우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.3
    • /
    • pp.2019-2028
    • /
    • 1970
  • 1. Experiments were made for the efficient plowing method by the 4 wheel tractor, the results are as follow; 1) In case of plowing of inner side of the field, the efficient turning method to be the smallest turning time is the $\Omega$-shaped turning method in the turning distance less than 2r (r is the minimum turning radius of the tractor), and also, it is the U-shaped turning method in the turning distance larger than 2r. 2) 2.5r is most efficient in the unit turning section 'w' on plowing of the inner side of the field. 3) In case of plowing of outer side of the field, intermitted plowing method is efficient in case of W>-0.0345 L + 35.84, and also, semi-followed plowing method is efficient in case of W<-0.0345 L + 35.84. 4) The smaller the width of outer side of outer side of the field 'I' is, the higher is the plowing efficiency, and it is estimated that the minimum value 2r is suitable to 'I' in plowing of inner side and outer side of the field. 2. Study on the correlation between the unit field and plowing efficiencies obtained the following results; 1) plowing efficienies increase generally according as length-width ratio L/W and area A increase. 2) Percent of increase of plowing efficiencies decreases generally according as length-width ratio and area enlarge. 3) The limit that change of T is large owing to L/W is 6 for 20 a, 5 for 30 a, 4 for 50 a, 3 for 80 a, less than 2.5 for 100 a, generally, in L/W-T curve. 4) Rate of change of T-A curve is similar to rate of change of $T=A-\frac{2}{3}$ curve in spite of influence of L/W. 5) In case that length-width ratio is more than 3, effects of increase of 10 a area influenced upon plowing efficiencies are as much as effects of about 5 increase of length width ratio without correlation of size of the field. 6) In case that length-width ratio is 2 to 3, effects of increase of 10 a area influenced upon plowing efficiencies are as much as effects of about 4 to 2 increase of length-width ratio without correlation of size of the field, and the effects decrease according as not only length-width ratio decreases but also area increases, generally.

  • PDF

On Line Formation Analysis for Gradient Trail (경사지 원로의 선형 분석)

  • 김용수;나정화
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.1
    • /
    • pp.45-60
    • /
    • 1986
  • The purpose of the present studies is to establish more rational and practical planning theory for trails of gradient. The results drawn from this research work are as follow ; Mean angle according to topography of Jiga road is $3^{\circ}$33'in low part, $8^{\circ}$17'in middle park and $12^{\circ}$48'in high part. Here, we can find that the highest gradient of Jige roacl is $12^{\circ}$48, Which is showing the fact that jigs road is the most function road when we compare other roads. The regression coefficient between potential model pattern and calculuted model pattern is 0.8 withinTEX>$ 0~<5^{\circ}$, 0.5 within$ 6~10^{\circ}$, and 0.53 within $11~16^{\circ}$. The linear of these model pattern is lower in R & L value, and lager in S & A value according to be steeping gradient. It is thought that these fact are closely related with between human fatigue and R.S.A.L value. Accordingly, when we plan the trails of the gradient in city park, the from of trails is right to mix straight line with curve line within $0~5^{\circ}$, and sine wave close curve line within $6~10 ^{\circ}$, $l1~16^{\circ}$. But, in fact, It is absurd that potential model pattern is applied to the city park in park of corner, widely road and facilities. Therefore, It is thought that the study of this problems will be proceeded in the future. I can reduce the following equation in relation R & S by gradient ; 22 log (R-6.0)=47.96-$\delta$

  • PDF

A Study for Experiment to Measure Mechanical Properties of Pressurizer Nozzle and Safety-Ends in Nuclear Power Plant (원전 가압기 노즐 및 안전단 재료에 대한 기계적 물성시험 연구)

  • Lee, Kyoung-Soo;Lee, Sung-Ho;Kim, Jin-Weon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.147-153
    • /
    • 2013
  • Recently the primary water stress corrosion cracking(PWSCC) has occurred in the dissimilar metal weld region between pressurizer nozzle and safe-end in nuclear power plants(NPPs). As material of the pressurizer nozzle, SA508 Gr. 3 low alloy steel was used. F316L stainless steel and Alloy 82/182 were used as safe-end and weld metal, respectively. Although mechanical properties are needed for evaluation of the structural integrity against flaw in the material, material specification and standard don't supply those properties. Therefore, the present study conducted tensile and fracture toughness tests on SA508 Gr.3 and F316L stainless steel at ambient temperature and operating temperature of NPPs and reported the tested results.