• 제목/요약/키워드: lCT

검색결과 565건 처리시간 0.023초

Evaluating Paraspinal Back Muscles Using Computed Tomography (CT) and Magnetic Resonance Imaging (MRI): Reliability Analysis and Correlation with Intervertebral Disc Pathology

  • Hwang, Eunjin;Antony, Chermaine Deepa;Choi, Jung-Ah;Kim, Minsu;Khil, Eun Kyoung;Choi, Il
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권2호
    • /
    • pp.109-117
    • /
    • 2021
  • Purpose: To investigate the reliability of CT and MRI for quantitative and qualitative analyses of lumbar paraspinal muscle fatty infiltration (PSFI) and correlation of PSFI with intervertebral disc pathology. Materials and Methods: Lumbar spine CT and MRI of 36 subjects were reviewed retrospectively. Two observers independently outlined lumbar paraspinal muscles at each mid-intervertebral disc level. Paraspinal muscles on CT and MRI were graded according to the Goutallier grading system (GGS). The area, mean value, and standard deviation (SD) of the Hounsfield unit (HU) were obtained. Intervertebral discs were assessed on axial image of T2WI at each level. Correlations between qualitative and quantitative data and intervertebral disc pathology, age, and sex were evaluated. Results: Inter- and intra-observer agreements for results of GGS on MRI were substantial (κ = 0.79) and moderate (κ = 0.59), respectively. Inter- and intra-observer agreements for results of GGS on CT were almost perfect (κ = 0.88) and substantial (κ = 0.66), respectively. Quantitative measurements of HU showed almost perfect inter- and intra-observer reliabilities (κ = 0.82 and κ = 0.99, respectively). There were statistically significant correlations between intervertebral disc pathology and PSFI at L1-2, L2-3, and L4-5 levels on MRI and at L1-2 and L3-4 levels on CT. Age showed significant correlation with results of GGS at all levels on CT and MRI. Conclusion: This study showed that GGS results and HU measurements could be useful for evaluating PSFI because they showed correlations with intervertebral disc pathology results at certain levels.

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

정상 혈청 크레아티닌을 가진 응급실 환자에서의 조영제 연관 신증 (Nephropathy related to computed tomography in emergency department patients with serum creatinine <1.5 mg/dL)

  • 김종하;박신률;김종근
    • Journal of Yeungnam Medical Science
    • /
    • 제32권2호
    • /
    • pp.90-97
    • /
    • 2015
  • Background: Contrast-induced nephropathy (CIN) can cause serious adverse effects. To reduce the occurrence of CIN related computed tomography (CT) in emergency patients, we assessed the respective roles of serum creatinine (SCr) alone and estimated glomerular filtration rate (eGFR) as an early predictor for CIN related CT. Methods: For patients with SCr <1.5 mg/dL who underwent CT in emergency department (ED) between September 2012 and October 2013, we assessed the prevalence of CIN and its adverse effects. The Modification of Diet in Renal Disease Study (MDRD) and Cockcroft-Gault (CG) formula was used for the calculation of eGFR. Practical calculation was performed by electronic medical record (EMR) system for MDRD and internet calculating service for CG. And we investigated the prevalence of CIN in eGFR $<60mL/min/1.73m^2$ before CT. Results: A total of 1,555 patients were enrolled. The prevalence of CIN after CT was 4.6% and it showed correlation with renal deterioration, increased in-hospital mortality, and prolonged hospitalization. Despite baseline SCr <1.5 mg/dL, among enrolled patients, 11.3% as MDRD equation and 29.5% as CG formula were $<60mL/min/1.73m^2$ and in this condition, the prevalence of CIN was significantly high (odds ratio was 2.87 [1.64-5.02] as MDRD equation and 2.03 [1.26-3.29] as CG formula). Conclusion: Just SCr <1.5mg/dL was not appropriate to recognize preexisting renal insufficiency, but eGFR using MDRD equation was useful in predicting the risk of CIN related CT in ED. Using EMR, calculation of eGFR can be easier and more convenient.

Reciprocal effect of ethyl formate and phosphine gas on two quarantine pests, Tetranychus urticae(Acari: Tetranychidae) and Myzus persicae(Hemiptera: Aphididae)

  • Kim, Bong-Su;Yang, Jeong-Oh;Roh, Gwang Hyun;Ren, Yonglin;Lee, Byung-Ho;Lee, Sung-Eun
    • 환경생물
    • /
    • 제39권3호
    • /
    • pp.336-343
    • /
    • 2021
  • Fumigation of fruits and vegetables during quarantine and pre-shipment(QPS) treatment should be effective with a shorter fumigation time to minimize phytotoxicity. In this research study, a shorter fumigation time, 2 hours exposure which is shorter than that of the current commercial fumigation procedures using a lower dose of ethyl formate (EF) mixed with phosphine (PH3) on strawberry was investigated. The reciprocal effect between EF and PH3 against nymphs and adult Myzus persicae (Sulzer) and Tetranychus urticae (Koch) was evaluated. In addition, L(Ct)50 and L(Ct)99 of EF only and EF mixed with PH3 were analyzed at 5℃ and 20℃. The synergistic ratio (SR) of L(Ct)50 and L(Ct)99 for the nymph and adult stages of M. persicae were >1.0, which indicated a synergistic effect between EF and PH3. However, the SR values of L(Ct)50 and L(Ct)99 of the nymph and adult stages of T. urticae were ≤1.0 indicating that there was no synergistic effect between the two fumigants against T. urticae. Our results showed that the reciprocal effect between EF and PH3 has different effects on M. persicae and T. urticae. This could be attributed to the biological and physical differences between the class Arachnida and Insecta. The synergistic effect between EF and PH3 against M. persicae within a shorter exposure period and without phytotoxicity on fruits and vegetables will significantly benefit the horticultural industry.

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권3호
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

컴퓨터 단층촬영 영상에서 3번 요추부 슬라이스 검출을 위한 최적화 기반 딥러닝 모델 (Optimization-based Deep Learning Model to Localize L3 Slice in Whole Body Computerized Tomography Images)

  • 채성원;조재현;박예은;정진형;김성진;최안렬
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.331-337
    • /
    • 2023
  • 본 논문에서는 근감소증의 발병 여부와 정도를 확인하기 위해 3번 요추부 (L3) CT 영상을 검출하는 딥러닝 모델을 제안하는 것이다. 또한, CT 데이터 내에 L3 레벨과 L3 레벨이 아닌 부분의 데이터 불균형으로 인한 성능 저하의 문제점을 오버샘플링 비율과 클래스 가중치를 설계변수로 하는 최적화 기법을 제시하고자 한다. 모델 학습 및 검증을 위하여 강릉아산병원에 내원한 전립선암 환자 104명, 방광암 환자 46명의 총 150명의 전신 CT 영상이 활용되었다. 딥러닝 모델은 ResNet50을 활용하였으며, 최적화기법의 설계변수로는 모델 하이퍼파라미터 5종과 데이터 증강비율 및 클래스 가중치로 선정하였다. 제안하는 최적화 기반의 L3 레벨 추출 모델은 대조군 (하이퍼파라미터 5종만을 최적화한 모델)과 비교하여 중간 L3 오차가 약 1.0 슬라이스 감소한 것을 확인할 수 있었다. 본 연구결과를 통하여 정확한 L3 슬라이스 검출이 가능하며, 추가적으로 데이터 증강을 통한 오버 샘플링과 클래스 가중치 조절을 통해 데이터 불균형 문제를 효과적으로 해결할 수 있는 가능성을 제시할 수 있다.

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

보상 알고리즘을 이용한 초고압 계통의 모선보호용 비율 전류차동 계전방식에 관한 연구 (A Study on a Percentage Current Differential Relaying Algorithm for EHV Bus Protection Using a Compensating Algorithm)

  • 강용철;윤재성;김동용;박종근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1139-1141
    • /
    • 1999
  • A variable percentage current differential relaying algorithm is widely used for bus protection. However, it may maloperate in case of high-impedance internal faults and external faults with CT saturation and thus additional method to cope with CT saturation is necessary. This paper proposes a percentage current differential relaying algorithm for bus protection using a compensating algorithm of secondary current of CTs. As the proposed method compensates the distorted secondary currents of CTs it can improves the sensitivity of relays in a large current region and does not need any additional method for CT saturation.

  • PDF

한국 유방암 환자에서 cancer/testis antigen의 발현분석 (A comprehensive Analysis of a Large Panel of Cancer/Testis (CT) Antigens in Korea Breast Cancer)

  • 배재호;김민주;박해림;송명하;김지연;이창훈;곽희숙;이상률
    • 생명과학회지
    • /
    • 제19권7호
    • /
    • pp.886-891
    • /
    • 2009
  • Cancer/testis(CT) antigens은 여러 종료의 암에서는 발현이 되지만, 정상조직에서는 고환에서만 발현이 되는 특이성을 가지고 있다. 이러한 특이성은 immunotherapy을 하기 위한 항암백신 개발에 매력적인 유전자로 알려져 있다. 본 연구에서는 29개의 한국유방암조직에서 13개의 CT antigens (NY-SAR35, SCP-1, SSX-1, SSX-2, SSX-4, MAGE-1, MAGE-3, MAGE-4, MAGE-10, CT-7, NY-TLU57, NY-ESO-1, and LAGE-1)의 발현빈도를 RT-PCR을 통하여 조사하고 환자의 임상학적 분류와 CT antigens의 발현빈도에 대하여 조사하였다. 29개의 유방암조직에 RT-PCR결과, 13개의 CT antigen중에 MAGE-3 (66%)와 MAGE-1(57%)에서 발현빈도가 가장 높았고 LAGE-1 (55%),NY-SAR-35 (49%),MAGE-4(41%), NY-ESO-1(38%), CT-7(24%), SSX-4(24%)순으로 발현빈도를 보였다. 그러나 SSX-1, SSX-2. MAGE-10와 NY-TLU-57의 발현은 3-7%로 매우 낮았고 특히 SCP-1는 발현되지 않았다. 29 유방암 조직에서 적어도 하나 이상의 CT antigen이 발현되는 샘플은 28(98%)이였다. 그러나 환자의 임상학적 분류와 CT antigens의 발현빈도와는 특징적인 관꼐가 없음을 알수있었다. 29개의 유방암조직에서 MAGE-3와 NY-ESO-1의 Protein level에서의 발현을 알아보기 위하여monoclonal antibody를 이용하여 면역조직염색을 하였다. MAGE-3은 29개 조직중에서 12개의 조직에서 발현되었으며 NY-ESO-1은 11개의 조직에서 발현되었다. 그러므로 CT antigens은 한국 유방암 조직에서 빈번하게 발현된 것을 알 수 있었으며 CT antigens을 기반으로 한 암 백신개발의 잠재적인 표적이 될 수 있을 것이라 사료된다.