• Title/Summary/Keyword: knife edge method

Search Result 37, Processing Time 0.023 seconds

Bare Wafer Inspection using a Knife-edge Test

  • Lee, Jun-Ho;Kim, Yong-Min;Kim, Jin-Seob;Yoo, Yeong-Eun
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.173-176
    • /
    • 2007
  • We present a very simple and efficient bare-wafer inspection method using a knife-edge test. The wafer front surface and inner structures are inspected simultaneously. The wafer front surface is inspected visually using a knife-edge test while the inner structure is simultaneously inspected by a camera in the infrared region with a single white-light source. This paper presents a laboratory implementation of the test method with some experimental results.

A Study on the Strength Comparison of Steel Pipe Support using the Structural Analysis Program (구조해석에 의한 파이프서포트의 내력비교에 관한 연구)

  • Paik, Shin-Won;Park, Jong-Keun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.67-71
    • /
    • 2008
  • Formwork is a temporary structure that supports its weight and that of fresh concrete as well as construction live loads. Slab formwork consists of sheathing, stringer, hanger and shore. In construction site, pipe supports are usually used as shores which are consisted of the slab formwork. In this study, compressive strength of 80 pipe supports was measured by knife edge test and plate test. Buckling load of pipe supports was analyzed by structural analysis program(MlDAS). Theoretical buckling load with/without initial deformation was got by theoretical analysis. According to these results, buckling load which was analyzed by structural analysis program(MlDAS) was larger than compressive strength of knife edge test and plate test. Theoretical buckling load without initial deformation was larger than compressive strength of knife edge test and plate test. But Theoretical buckling load with initial deformation was lower than compressive strength of knife edge test and plate test. Initial deformation equation for test method according to the pipe support length was suggested. Therefore, the present study results will be used to design the slab formwork safely.

Bare-ware inspection method using knife-edge optical test (칼날 측정법을 이용한 베어 웨이퍼 검사 방법)

  • Lee, Jun-Ho;Kim, Yong-Min;Kim, Jin-Seop;Hwang, Byeong-Mun
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.65-66
    • /
    • 2007
  • We present a new simple and fast bare-wafer inspection method. This method inspects the wafer front surface and inner structures simultaneously. The wafer surface is inspected using a knife-edge test in visible while the inner structure is inspected by a looking-through camera in infrared, at the same time and with a single white-light source. This paper presents a laboratory implementation of the test method with some experimental results.

  • PDF

Effect of the Elasticity Modulus of Jig Material on Blade Edge Shape in Grinding Process of Sapphire Medical Knife (사파이어 의료용 나이프의 연삭가공에서 지그의 탄성계수가 날 부 형상에 미치는 영향)

  • Shin, Gun-Hwi;Lee, Deug-Woo;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.102-107
    • /
    • 2017
  • This study focuses on the effect of the elasticity modulus of jig material on blade edge shape in the grinding process of a sapphire medical knife. The ELID grinding process was applied as the edge-grinding method for sapphire material. Carbon steel and copper have been selected as the hard and soft jig materials, respectively. The blade edge created by ELID grinding was measured by a surface roughness tester and optical microscope. The shape of the ground edge and surface roughness were compared using the measurement results. As a result, it was found that chipping in the blade edge of the sapphire knife occurred more than in the case of jig material with a high-elasticity modulus because of the high normal force in the grinding process. Moreover, the maximum height surface roughness, $R_{max}$,of the ground surface was higher in the case of the jig material with a high-elasticity modulus due to the difference in elasticelongation. It was considered to lead to chipping from the notch effect.

Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test (열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해)

  • Lee, Ho-Jin;Kim, Maan-Won;Lee, Bong-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.62-67
    • /
    • 2005
  • An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

The Analysis of Scattering Characteristics of a Prime-focus Offset Parabolic Antenna with a Shaped Edge Structure (정형 모서리 구조를 갖는 옵\ulcornerV 파라볼릭 안테나의 산란 특성 해석)

  • 박대성;김형규;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.412-418
    • /
    • 1999
  • The scattering characteristics of a prime-focus offset-parabolic antenna are analyzed using UTD. First, ray tracing method is used to locate the shadow boundaries, and then UTD is utilized to evalute the far-zone scattered magnetic field pattern. The field components included in the UTD analysis are the reflected, edge diffracted and creeping waves. The effects of circular caps attached to both edges of a prime-focus offset-parabolic antenna are investigated by comparing the scattered magnetic field patterns with those of a knife edge parabolic reflector.

  • PDF

Evidence Retrieval System using Edge and Generalized Hough Transform (Edge와 GHT를 이용한 증거물 검색 시스템)

  • 황혜정;채옥삼
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.233-236
    • /
    • 2003
  • In this paper, we propose a method to search the evidence such as a knife found in the crime scene based on GHT from an image database Such objects like knives are simitar in shape. The proposed method utilizes the small shape differences among objects as much as possible to distinguish an object from similar shaped objects. It consists of the GHT based candidate generation and top-down candidate verification. For the fast generation of the candidate 1ist, the GHT operation is performed un the down sampled edge list. The test results show that it can retrieve the correct object even with a pan of object in reasonable time.

  • PDF

MTF Assessment and Image Restoration Technique for Post-Launch Calibration of DubaiSat-1 (DubaiSat-1의 발사 후 검보정을 위한 MTF 평가 및 영상복원 기법)

  • Hwang, Hyun-Deok;Park, Won-Kyu;Kwak, Sung-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.573-586
    • /
    • 2011
  • The MTF(modulation transfer function) is one of parameters to evaluate the performance of imaging systems. Also, it can be used to restore information that is lost by a harsh space environment (radioactivity, extreme cold/heat condition and electromagnetic field etc.), atmospheric effects and falloff of system performance etc. This paper evaluated the MTF values of images taken by DubaiSat-1 satellite which was launched in 2009 by EIAST(Emirates Institute for Advanced Science and Technology) and Satrec Initiative. Generally, the MTF was assessed using various methods such as a point source method and a knife-edge method. This paper used the slanted-edge method. The slantededge method is the ISO 12233 standard for the MTF measurement of electronic still-picture cameras. The method is adapted to estimate the MTF values of line-scanning telescopes. After assessing the MTF, we performed the MTF compensation by generating a MTF convolution kernel based on the PSF(point spread function) with image denoising to enhance the image quality.

Simulation of Charging Process in Forming Electret for Sensor Material (센서재료용 일렉트렛트 형성에 대전과정 시뮬레이션)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.185-188
    • /
    • 2011
  • In order to estimate spatial charging process in the corona charging which has been used to make polymer electret, the electrical properties of polypropylene film were obtained from Thermally Stimulated Current(TSC) measurements after corona charging between knife electrode and cylinder electrode with the voltages of -5, -6, -7 and -8[kV], respectively. And then the electrostatic contour and the electric field vector were also simulated by using Finite Element Method(FEM). The edge effect around edge of knife electrode affected the electrostatic contour on surface of specimen and the electric field concentration inside specimen. The uneven charging state in the electret due to the mistake on design could be calculated and so the optimal design of corona charging device which is appropriate to various materials is come to be practicable.

  • PDF

Simulation of the Corona Charging Process in Polypropylene Electret for Sensor Material

  • Park, Geon-Ho;Park, Young-Chull;Yang, Jung-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.68-72
    • /
    • 2000
  • In order to estimate spatial charging process in the corona charging which has been used to make polymer electret, the electrical properties of polypropylene film were obtained from Thermally Stimulated Current (TSC) measurements after corona charging between knife electrode and cylinder electrode with the voltages of -5, -6, -7 and -8[kV], respectively. And then the electrostatic contour and the electric field vector were also simulated by using Finite Element Method (FEM). The edge effect around edge of knife electrode affected the electrostatic contour on surface of specimen and the electric field concentration inside specimen. The uneven charging state in the electret due to the mistake on design could be calculated and so the optimal design of corona charging device which is appropriate to various materials is come to be practicable.

  • PDF