• Title/Summary/Keyword: knee orthosis

Search Result 29, Processing Time 0.03 seconds

Vibration Control of a Knee Joint considering Human Vibration of the Biped Walking RGO for a Trainning of Rehabilitation(II) (척수마비환자 재활훈련용 보행보조기의 인체진동을 고려한 무릎관절 시스템 진동제어 (II))

  • Kim, Myung-Hoe;Yang, Hyun-Seok;Baek, Yun-Soo;Park, Young-Pil;Park, Chang-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.347.2-347
    • /
    • 2002
  • This paper presented a design and a Vibration control of a biped walking RGO(Robotic Gait Orthosis) and walking simulation by this system. The vibration evaluation of the Knee Joint Mechanism on the biped walking RGO(Robotic Galt Orthosis) was used to access by the 3-axis accelerometer with a low frequency vibration for the spinal cord injuries. It will be expect that the spinal cord injury patients are able to recover effectively by a biped walking RGO. (omitted)

  • PDF

Vibration Control of a Knee Joint System considering Human Vibration of the New R.G.O. for a Rehabilitation Trainning of Paraplegia (II) (척수마비환자 재활훈련용 보행보조기의 인체진동을 고려한 무릎관절 시스템 진동제어(II))

  • Kim, Myung-Hoe;Jang, Dae-Jin;Baek, Yun-Soo;Park, Young-Pil;Park, Chang-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.446-452
    • /
    • 2002
  • This paper Presents a 3-D design and a Vibration control of a new walking R.G.O.(Robotic Gait Orthosis) and would like to develop a simulation by this walking system. The vibration control and evaluation of the new knee joint mechanism on the biped walking R.G.O.(Robotic Gait Orthosis) was a very unique system and was to obtain by the 3-axis accelerometer with a low frequency vibration for the paraplegia It will be expect that the spinal cord injury patients are able to recover effectively by a biped walking R.G.O.. The new knee joint system of both legs were adopted with a good kinematic characteristics. It was designed attached a DC-srevo motor and controller, with a human wear type. It was able to accomodate itself to a environments of S.C.I. Patients. It will be expect that the spinal cord injury patients are able to recover effectively by a new walking R.G.O. system.

  • PDF

Effects of Flexible and Semirigid Lumbosacral Orthosis on Lower-Limb Joint Angles during Gait in Patients with Chronic Low Back Pain: A Cross-Sectional Study

  • Im, Sang-Cheol;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE: Lumbosacral orthosis (LSO) is often used to help manage low back pain because it is economical and effective. This study examined the effects of flexible and semirigid LSOs on the lower-limb joint angles in walking in patients with chronic low back pain. METHODS: The effects of the lumbosacral orthosis during gait on the sagittal, frontal, horizontal planes and the change in lower limb angle were examined in fourteen chronic low back pain patients who walked without wearing a LSO, wearing a flexible LSO, and wearing a semirigid LSO in random order for three-dimensional motion analysis. RESULTS: The flexion of the hip and knee joints decreased more significantly during walking with an LSO than without one. The genu valgum angles were reduced in the stance phase more during walking with an LSO than without one. The external rotation of the knee joints in the stance phase increased more during walking with an LSO than without one. CONCLUSION: The angles of the lower-limb joints of patients with chronic low back pain are affected by walking with an LSO, and the effects increased as the LSO stiffened.

Efficacy of a Knee Walker for Foot and Ankle Patients: Comparative Study with an Axillary Crutch (족부 족관절 환자에서 Knee Walker의 유용성: 액와 목발(Axillary Crutch)과의 비교 연구)

  • Song, Jae Hwang;Kang, Chan;Kim, Sang Bum;Heo, Youn Moo;Won, You Gun;Jung, Sang Jin;Chung, Hyung Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.100-104
    • /
    • 2018
  • Purpose: An axillary crutch is the most commonly used assistive device in foot and ankle patients who require nonweightbearing. On the other hand, its use frequently induces axillary or wrist pain and critical neurovascular injuries have been reported in several studies. This study compared the clinical outcomes of patients using the knee walker and axillary crutch. Materials and Methods: A retrospective analysis was performed comparing the utility of a knee walker and axillary crutch as a nonweightbearing ambulatory aid for 62 foot and ankle patients treated between November 2016 and March 2018. A comparative study of the two orthosis could be performed because all the patients temporarily used an axillary crutch before or after the use of a knee walker. A demographic study and comparative analysis based on the visual analogue scale (VAS) satisfaction score (0~100), complications, and fall down history were evaluated. Furthermore, under the assumption of having retreatment, their preference of orthosis between the knee walker and axillary crutch was investigated. Results: The mean age of the patients was 36.5 and the mean duration of ambulation with a knee walker and axillary crutch were 5.2 and 2.4 weeks. The VAS satisfaction score of the knee walker and crutch was 88.8 and 27.5, respectively (p<0.05). The most frequent complications of the knee walker and crutch were ipsilateral knee pain (6 cases) and axillary or wrist pain (56 cases), respectively. No case of falling down occurred during knee walker ambulation, but there were two cases of crutch ambulation. Fifty-eight patients (93.5%) preferred the knee walker and four patients (6.5%) preferred a crutch. Conclusion: Compared to the axillary crutch, the knee walker afforded lower complication and higher satisfaction. Most patients preferred the knee walker to a crutch. Therefore, the knee walker is an efficient and safe orthosis for foot and ankle patients who require nonweightbearing.

Effect of Exoskeleton Orthosis for Assistance of Dorsiflexion Torque in Walking Pattern and Lower-limb Muscle (족배굴곡 보조용 외골격 보조기가 보행자의 보행패턴 및 하지근육에 미치는 효과)

  • Oh, H.J.;Kim, K.;Jeong, G.Y.;Jeong, H.C.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • In this study, the exoskeleton orthosis for the assistance of dorsiflexion torque in ankle joint to prevent foot-drop was developed. It was consist of three part; 1) the power part using artificial pneumatic actuator, 2) wearing part of ankle and knee joints to fix the orthosis, and 3) control part to detect the gait phase using physiological signal. The dorsiflexion torque was generated by the artificial pneumatic actuator connected with wearing part between ankle and knee joint. The accurate timing to assist dorsiflexion torque is made up of physiological signal in foot sole part that detect the gait phase, that is, stance and swing phase in each foot. We conduct the experiment to investigate the effect of exoskeleton orthosis to the 7 elderly people and 10 healthy people. The result showed that the muscular activities in tibialis anterior muscle were reduced because of the assistance of dorsiflexion torque in ankle joint using the exoskeleton orthosis.

  • PDF

Estimation of Knee Muscle Length and Moment Arm Using Knee Joint Angle (무릎 관절각을 이용한 무릎 근육 길이와 모멘트 암 추정)

  • Lee, Jae-Kang;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.167-176
    • /
    • 2008
  • Recently, lots of studies are performed in developing of active orthosis. Exact and simple muscle force estimation is important in developing orthosis which assists muscle force for disabled people or physical laborers. Hill-type muscle model dynamics is common method for estimation of muscle forces. In Hill-type muscle model, we must know muscle length and moment arm which largely affect muscle force. And several methods are proposed to estimate muscle length and moment arm using joint angle. In this study, we compared estimation results of those method with data from body model of opensim to find which method is exact for estimation of muscle length and moment arm.

  • PDF

Study on the Gait Pattern of the Aged with Lower Limbs Orthosis

  • Kim, Kyong;Kim, Seong-Hyun;Kim, Young-Chul;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2444-2447
    • /
    • 2005
  • The purpose of this study was to analyze the gait motion of the aged with a lower limbs orthosis. The gait motion was analyzed with and without lower limbs orthosis using APAS 3D Motion Analysis System. The pattern of lower limbs motion was tracked based on four targets attached to the body of the subject. The targets were positioned at hip, knee, ankle, and foot. The parameters measured were the displacement, the velocity, and the acceleration of the four targets. The improvement in the measured values on the displacement and the velocity of the four targets were small with the orthosis due to inconvenience of wearing it, but the increase in the acceleration was large due to the elastic force of the rubber actuator. Especially, the increase of the acceleration of foot with lower limbs orthosis seems to help the gait motion of the elderly.

  • PDF

Knee Joint Control of New KAFO for Polio Patients Gait Improvement (소아마비 환자의 보행개선을 위한 새로운 장하지 보조기의 무릎관절 제어)

  • 강성재;조강희;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.132-135
    • /
    • 2002
  • In the present study, an electro-mechanical KAFO (knee-ankle-foot orthosis) which satisfies both the stability in stance and the knee flexion in swing was developed and evacuated in eight polio patients. A knee joint control algorithm suitable for polio patients who are lack of the stability in pre-swing was also developed and various control systems and circuits were also designed. In addition, knee flexion angles and knee moments were measured and analyzed for polio patients who used the developed KAFO with the three-dimensional motion analysis system. Energy consumption was also evaluated for the developed KAFO by measuring the movement of the COG (center of gravity) during gait. From the present study, the designed foot switch system successfully determined the gait cycle of polio patients and controlled knee joint of the KAFO, resulting in the passive knee flexion or foot clearance during swing phase. From the three-dimensional gait analysis for polio patients, it was found that the controlled-knee gait with the developed electro-mechanical KAFO showed the knee flexion of 40$^{\circ}$∼45$^{\circ}$ at an appropriate time during swing. Vertical movements of COG in controlled-knee gait (gait with the developed electro-mechanical KAFO) were significantly smaller than those in looked knee gait(gait with the locked knee Joint). and correspondingly controlled-knee gait reduced approximately 40% less energy consumption during horizontal walking gait. More efficient gait patterns could be obtained when various rehabilitation training and therapeutic programs as well as the developed electro-mechanical KAFO were applied for polio patients.

  • PDF