• Title/Summary/Keyword: knee MRI

Search Result 133, Processing Time 0.024 seconds

Comparative Study of a Multi-Channel Coils of Magnetic Resonance Imaging(MRI) Signal Intensities under Identical Parameters (동일한 조건의 자기공명검사에서 코일의 채널수 변화에 따른 신호강도의 평가)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.418-423
    • /
    • 2019
  • The purpose of this study was to determine how the different number of channels of coils were related in the perceived signal intensity under identical parameters and area. Dedicated knee phantoms were scanned consecutively using both of the 16-channel and 8-channel knee coils. The T1 weighted and T2 weighted sequences were acquired using both coils to compare the signal intensities according to the number of channels. As a result, the 16-channel knee coils outperformed the 8-channel knee coils and the signal intensity was significantly increased in both of the T1 and T2 weighted images with the 16-channel coil. In conclusion, it is considered that better signal intensities and more clinical utility can be provided, when coils with more number of channels are used rather than using the coils with smaller number of channels.

Evaluation of O-MAR XD Technique for Reduction of Magnetic Susceptibility Artifact of Knee Implant (인공 무릎관절에서 자화율 인공물의 감소를 위한 O-MAR XD 기법의 평가)

  • Lee, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.413-419
    • /
    • 2018
  • Magnetic Resonance Imaging for patients with metallic implant has poor image quality, and signal loss and artifacts including distortion can occur. The purpose of this study is to carry out a comparative evaluation on high receive bandwidth(hiBW), O-MAR, O-MAR XD to reduce artifacts in knee implant. To take MRI, 3.0T scanner and dual-source radiofrequency transmission were used. O-MAR XD technique's strong option showed a significant difference (p<0.001) with O-MAR XD technique's weak option, O-MAR and hiBW excluding the medium option. O-MAR XD's medium option had a significant difference (p<0.01) with O-MAR XD's weak, O-MAR and hiBW. O-MAR XD technique's weak option had a significant difference (p<0.01) with O-MAR XD's strong and medium options, O-MAR and hiBW. O-MAR technique had a significant difference (p<0.001) with strong, medium, weak options of O-MAR XD technique except for hiBW. HiBW had a significant difference (p<0.001) with strong, medium and weak options of O-MAR XD technique except for O-MAR. The results showed that O-MAR XD technique was more useful for MRI scan for patients with knee replacement surgery than traditional techniques such as hiBW or O-MAR, and susceptibility artifacts decreased more when O-MAR XD technique's strong or medium option was applied. Based on the results above, it is considered that it will be possible to acquire images whose susceptibility artifacts were highly decreased by using O-MAR XD technique's strong or medium option when conducting MRI for artificial knee joint and it will be helpful for checking and monitoring patients with knee joint replacement.

Overview of the Sonography of the Knee Joint (슬관절 초음파 개론)

  • Kim, Jung-Man
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.94-111
    • /
    • 2008
  • Traditionally the diagnosis and treatment of the diseases of the knee is based on the findings of the x-rays and the MRI. The x-rays provide good information of the changes of the internal structure of the bone. However, there is a limitation in providing information of the soft tissue and the cartilage. The MRI is one of the most expensive diagnostic modalities and it can not give us a dynamic and real time information. The sonography has a role in diagnosis and treatment of the soft tissue disease and surface of the bone. It gives us a real time dynamic information and it is really cheap. In this article the sonographic findings of the normal and pathologic conditions of the knee joint are introduced in relation to the findings of the x-rays and the MRI.

  • PDF

Mucoid Degeneration of Anterior Cruciate Ligament: Correlation between MR Imaging and Pathologic Findings in Patients with Osteoarthritis of the Knee (앞십자 인대의 점액 변성: 슬관절 퇴행성 관절염 환자에서 MRI 소견과 병리소견의 연관)

  • Ryu, Jeong-Ah;Liew, Hyun-Jeong;Kim, Sung-Moon;Shin, Myung-Jin;Shin, Hee-Jung;Cho, Kyung-Ja;Cho, Woo-Shin;Kang, Chang-Ho;Lee, Min-Hee;Kim, Mi-Sung;Park, Noh-Hyuck;Lee, Sang-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • Purpose : To evaluate the mucoid degeneration (MD) of the anterior cruciate ligament (ACL) of the knee by correlation of MRI findings with pathology, in the patients with osteoarthritis (OA). Materials and Methods : This study included 17 patients (mean 68.8 years old) who underwent preoperative MRI. In proton density-weighted sagittal and coronal images ACLs were evaluated for the thickness and signal intensity (SI). Total knee replacement arthroplasty was performed and the pathologic findings of ACL were evaluated. MD was classified as 3 grades according to the degenerated amount in microscopy. Thickness and SI was evaluated as normal or increased on MRI. Results : All of the 4 patients who showed thickened ACL showed increased SI on MRI. All of the 8 patients with increased SI of the ACL on MRI had MD in the ACL. However, remained 9 patients also had MD, in spite of their normal thickness and SI on MRI. Calcification was seen in 5 patients. Conclusion : Eight cases who showed ACL thickening or increased SI on MRI were well correlated with MD, however, because the other nine cases who showed normal thickness and normal SI of ACL on MRI also showed MD in pathology, normal MRI finding should not exclude the possibility of MD of ACL.

  • PDF

Magnetic Resonance Imaging of ACL Injury (전방십자인대 손상의 자기공명영상)

  • Song, Eun-Kyoo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.31-35
    • /
    • 1997
  • MRI(magnetic resonance imaging) is very useful to visualize the anterior cruciate ligament (ACL) injury of the knee. Differential features of ACL injury at MRI according to acute and chronic stage should be evaluated to enable accurate assessment of the integrity or ACL. Distinguishing features of normal anatomy. acute and chronic injuries or ACL at MRI will be reviewed.

  • PDF

Construction and Measurement of Three-Dimensional Knee Joint Model of Koreans (한국인의 3차원 무릎관절 구축 및 형상 측정)

  • Park, Ki-Bong;Kim, Ki-Bum;Son, Kwon;Suh, Jeung-Tak;Moon, Byung-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1664-1671
    • /
    • 2004
  • It is necessary to have a model that describes the feature of the knee Joint with a sufficient accuracy. Koreans, however, do not have their own knee joint model to be used in the total knee replacement arthroplasty. They have to use European or American models which do not match Koreans. Three-dimensional visualization techniques are found to be useful in a wide range of medical applications. Three-dimensional imaging studies such as CT(computed tomography) and MRI(magnetic resonance image) provide the primary source of patient-specific data. Three-dimensional knee joint models were constructed by image processing of the CT data of 10 subjects. Using the constructed model, the dimensions of Korean knee joint were measured. And this study proposed a three-dimensional model and data, which can be helpful to develop Korean knee implants and to analyze knee joint movements.

Effectiveness of Oriental Medical Therapy and Bongchuna on Anterior Cruciate Ligament Rupture of Knee, Two Case Reports (슬관절의 전방십자인대파열에 대한 한방치료와 봉추나의 치료효과 증례 2)

  • Oh, Won-Kyo;Kwon, Young-Dal;Song, Yung-Sun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.241-254
    • /
    • 2010
  • Anterior cruciate ligament tear is a common disease of knee injury. We report 1 case of anterior cruciate ligament complete tear diagnosed by MRI(magnetic resonance imaging) imaging and 1 case after reconstruction. Outcomes were measured by visual analogue scale(VAS) and Lysholm knee scoring scale. We applied acupuncture treatment, bee venom injection, bongchuna and prescribed herbal medication. Patients who treated by oriental medical treatments had a significant effect on the pain decrease and range of motion and knee function. Oriental medical treatments are very useful on pain reduction and prevention of muscle contraction, leading to satisfied rehabilitation, as wee as diminishing recurrence after operation.

A Comparative Study of SNR and Image According to the Aplication Coil in MRI Inspection (자기공명영상검사에서 Coil적용에 따른 SNR과 영상의 비교연구)

  • Park, Ye-won;Lim, Cheong-hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.147-148
    • /
    • 2015
  • MRI검사 시 다양한 환자를 고려한 변화에 적절한 coil의 선택과 조건에 따른 SNR의 차이를 조사하여 우수한 SNR의 영상을 획득하고자 한다. MR영상 획득실험은 Bottle Phantom를 이용하여 Philips achieva 1.5T와 SIMENS 1.0T을 이용하여 sequence별, surface coil별로 MR영상을 획득하여 SNR를 구하였다. 주자장이 1.0T에서 가장 높은 SNR은 TSE와 FLAIR에서 knee coil, GE에서 head coil로 측정되었고, 주자장이 1.5에서 가장 높은 SNR은 TSE에서 head coil, FLAIR와 GE에서 knee coil로 측정되었다. 본 연구에서 획득한 결과를 중심으로 다양한 환자를 고려한 변화에 따른 적절한 coil의 선택과 조건에 따라 SNR의 차이를 조사하여 우수한 SNR의 영상을 제시하여야 한다.

  • PDF

Displaced Double-Layered Lateral Meniscus That Mimicked the Bucket-Handle Tear: a Case Report

  • Kwak, Min Jee;Kim, Sun Ki;Kim, Ki Jun;Lee, Bum-Sik;Kang, Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.191-195
    • /
    • 2016
  • Among the various types of congenital meniscal anomalies, the double-layered lateral meniscus is extremely rare. The double-layered meniscus consists of both the upper additional and the lower normal meniscus. As the upper additional meniscus is mobile, it can be easily displaced, while the lower lateral meniscus is usually normal in shape and volume. A 42-year-old woman suffering from pain and locking of her left knee underwent Magnetic resonance imaging (MRI) examination and an arthroscopic surgery. A rare meniscal abnormality was seen in her left knee, which presented as a double-layered lateral meniscus with displacement. It was remarkable that the upper additional meniscus was displaced over the intercondylar eminence of the tibia and it mimicked a bucket-handle tear. Even though it is rare, it is necessary to consider the possibility of displaced double-layered meniscus in the differential diagnosis of a bucket-handle tear. Here, we report the MRI and arthroscopic findings of a displaced double-layered lateral meniscus, which was similar to the bucket-handle tear.

Calcifying Aponeurotic Fibroma of the Knee: a Case Report with Radiographic and MRI Finding

  • Lee, Seung Hyun;Lee, In Sook;Song, You Seon;Choi, Kyung Un;Kim, Jeung Il;Song, Jong Woon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.259-263
    • /
    • 2017
  • Calcifying aponeurotic fibroma (CAF) is an uncommon benign tumor and a locally aggressive fibroblastic lesion. It commonly affects the palmar side of the hand and fingers, and the soles of the feet. The typical clinical manifestations are known as a poorly circumscribed, slow-growing, and asymptomatic firm mass. Most CAFs usually reveal low to intermediate or isointensity on T1-weighted images, and strong heterogeneous enhancement. However, various signal intensities on T2-weighted images have been reported depending on the degree of hypocellularity or the amount of calcification or collagen within the tumor. This report provides the radiographic and MRI finding of CAF arising in uncommon site, the knee region, of a 19-year-old male who presented with a painful and palpable mass.