• 제목/요약/키워드: kinematic calibration

검색결과 75건 처리시간 0.026초

Off-line programming sysytem을 위한 로보트운동계의 calibration (Calibration of robot kinematics for the off-line programming system)

  • 김문상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.511-517
    • /
    • 1988
  • Movement order program of robot operating program is generally made by teach-in method. Therefore in most cases it is sufficient as long as the robot system shows a reguired repeatability for the working conditions. But the trend in the robot application moves to the automatic generation of the working programs. A mathematical robot model similar to the reality is necessary for the analysis of the kinematic transformation of the robot system. The purposes of this paper are to make a better describing form and to suggest an automatic algorithm for kinematic parameter identification.

  • PDF

A Calibration of Kinematic Differences between the Robot Model in OLP and Actual SCARA Robot

  • Ahn, Cheol-Ki;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.111-116
    • /
    • 1998
  • In this study, we try to coincide virtual robot system in an OLP(off-line programming) with actual robot system even though kinematic differences between them are made. The virtual robot in the OLP may be modeled according to kinematics of the actual robot system. However, it is a complicated problem to find exactly all kinematic parameters of actual robot and environment. In this paper, an automated calibration method is proposed In order to find some kinematical parameters which are necessary for the modeling of a robot and environment in the OLP. It is applicable to SCARA robot for assembly task. In this method, a well-marked worktable of environment Is regarded as reference coordinate frame. The robot detects some marks on the worktable through sensors attached to the end-effector. The necessary parameters are calculated from the data of the robot joint variables when the robot detects the mark. The model in the OLP is modified by the parameters.

  • PDF

새로운 측정장비를 이용한 병렬구조 로봇의 보정에 관한 (Calibration of Parallel Manipulators using a New Measurement Device)

  • 압둘라우프;김성관;류제하
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1494-1499
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can be used to identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise.

  • PDF

스카라 로봇의 오프라인 프로그래밍을 위한 시각정보 보정기법 (A Visual Calibration Scheme for Off-Line Programming of SCARA Robots)

  • 박창규;손권
    • 대한기계학회논문집A
    • /
    • 제21권1호
    • /
    • pp.62-72
    • /
    • 1997
  • High flexibility and productivity using industrial robots are being achieved in manufacturing lines with off-line robot programmings. A good off-line programming system should have functions of robot modelling, trajectory planning, graphical teach-in, kinematic and dynamic simulations. Simulated results, however, can hardly be applied to on-line tasks until any calibration procedure is accompained. This paper proposes a visual calibration scheme in order to provide a calibration tool for our own off-line programming system of SCARA robots. The suggested scheme is based on the position-based visual servoings, and the perspective projection. The scheme requires only one camera as it uses saved kinematic data for three-dimensional visual calibration. Predicted images are generated and then compared with camera images for updating positions and orientations of objects. The scheme is simple and effective enough to be used in real time robot programming.

차륜형 이동로봇의 오도메트리 보정을 위한 실험적 주행시험경로 설계 (Design of Experimental Test Tracks for Odometry Calibration of Wheeled Mobile Robots)

  • 정창배;문창배;정다운;정우진
    • 로봇학회논문지
    • /
    • 제9권3호
    • /
    • pp.160-169
    • /
    • 2014
  • Odometry using wheel encoder is a common relative positioning technique for wheeled mobile robots. The major drawback of odometry is that the kinematic modeling errors are accumulated when the travel distance increases. Therefore, accurate calibration of odometry is required. In several related works, various schemes for odometry calibration are proposed. However, design guidelines of test tracks for odometry calibration were not considered. More accurate odometry calibration results can be achieved by using appropriate test track because the position and orientation errors after the test are affected by the test track. In this paper, we propose the design guidelines of test tracks for odometry calibration schemes using experimental heading errors. Numerical simulations and experiments clearly demonstrate that the proposed design guidelines result in more accurate calibration results.

구속연산자에 의한 보정 시스템의 관측성에 관한 연구 (Study on the Observability of Calibration System with a Constraint Oprerator)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.647-655
    • /
    • 2003
  • This paper studies the observability of calibration system with a constraint movement by a constraint operator. The calibration system with the constraint movement need only simple sensing device to check whether the constraint movements are completed within an established range. However, it yields the concern about the poor parameter observability due to the constraint movements. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters are examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a parallel typed machining center and the calibration results are presented. These results verify that the calibration system with low-cost indicators and simple planar table is accurate as well as reliable.

3차원 미소변위센서 기반 로봇 캘리브레이션 성능 검토 (Evaluation of Robot Calibration Performance based on a Three Dimensional Small Displacement Measuring Sensor)

  • ;강희준
    • 제어로봇시스템학회논문지
    • /
    • 제20권12호
    • /
    • pp.1267-1271
    • /
    • 2014
  • There have been many autonomous robot calibration methods which form closed loop structures through the various attached sensors and mechanical fixtures. Single point calibration among them has been used for on-site calibration due to its convenience of implementation. The robot can reach a single point with infinitely many configurations so that single point calibration algorithm can be set up and easily implemented relative to the other methods. However, it is not still easy to drive the robots' sharp edge to its corresponding edge of the fixture. This is error-prone process. In this paper, we propose a 3 dimensional small displacement measuring sensor and a robot calibration algorithm based on this sensor. This method relieves the difficulty of matching two edges in the single point calibration and improves the resulting robot accuracy. Simulated study is carried out on a Hyundai HA06 robot to show the effectiveness of the proposed method over the single point calibration. And also, the resulting robot accuracy is compared with that from 3D laser tracker based calibration to show the dependency of robot accuracy on range of the workspace where the measurement data are collected.

칩마운터를 위한 통합 오차 측정 및 평가 시스템 개발에 관한 연구 (A study on the development of the integrated error measurement and calibration system for a chip mounter)

  • 이동준;문준희;박희재;정상호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.366-370
    • /
    • 2002
  • A kinematic ball bar measurement system can analyze the various errors of a machine tool easily and rapidly in a procedure and can measure many types of equipment such as chip mounter, PCB router, precision stage, etc. In this paper, the thermally induced errors are loused among various errors of a chip mounter because it affects the accuracy of the machine very much. Linear regression technique is adapted for the thermal error modeling. While the measurement and calibration of a chip mounter is difficult in general, this developed system is not only easy to apply for it but also improves the accuracy by 4 times or more.

  • PDF

아아크 용접용 로보트의 오프라인 프로그램 응용을 위한 효과적 캘리브레이션 방법 연구 (An Efficient Calibration Procedure of Arc Welding Robots for Offline Programming Application)

  • 범진환
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.131-142
    • /
    • 1996
  • Most industrial robots cannot be off-line programmed to carry out a task accurately, unless their kinematic model is suitably corrected through a calibration procedure. However, normal calibration is an expensive and time-consumming precedure due to the highly accurate measurement equipment required and due to the significant amount of data that must be collected. This paper presents a simple and economic procedure to improve the efficiency of robot calibration especially for arc welding application. To simplify the measurement process, an automotic data measurement algorithm as well as a simple measurement device are developed. Also, a calibration algorithm which can automatically identify the independent model parameters to be estimated is presented. To demonstrated the simplicity and the effectiveness of the procedure, experimental studies and computer simulations are performed and their results are discussed.

  • PDF

K-DRUM 개선을 위한 초기토양함수 자동보정기법 개발 (A Development of Auto-Calibration for Initial Soil Condition in K-DRUM Model)

  • 박진혁;허영택
    • 대한공간정보학회지
    • /
    • 제17권2호
    • /
    • pp.71-79
    • /
    • 2009
  • 본 연구에서는 격자강우량과 격자기반의 GIS수문 매개변수와 연계하여 홍수기 유출량의 시공간적 분포를 파악할 수 있도록 물리적인 운동파 이론에 근거한 분포형 강우-유출모형인 K-DRUM을 자체 개발하였다. 이 모형은 홍수 기동안의 지표흐름과 지표하 흐름의 시간적 변화와 공간적 분포를 모의할 수 있으며, 전처리과정으로서 ArcView 를 이용하여 모형에 필요한 ASCII형태의 입력 매개변수 자료들을 가공하였다. 또한 후처리과정으로서 모형의 수행결과인 유역내의 유출량 분포 등을 GIS상에서 나타낼 수 있도록 ASCII형태로 출력하도록 구성하였으며 TecPlot 을 이용하여 유출량을 에니메이션으로 표현하였다. 또한, 유출량에 가장 큰 영향을 미치는 초기토양함수 상태에 대한 자동보정기법을 추가 개발하였으며, 남강댐유역을 대상으로 기저유출해석을 수행하여 개발된 자동보정기법의 활용가능성을 검토하였다. K-DRUM모형의 초기토양함수조건을 설정하는데 있어서 자동보정기법을 적용함으로써 기존의 시행착오법으로 인해 소요되는 시간과 부정확한 설정으로 발생될 수 있는 문제점을 해결할 수 있었다.

  • PDF