• 제목/요약/키워드: kinematic calibration

검색결과 75건 처리시간 0.035초

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

차량형 이동로봇의 기구학적 파라미터 보정을 위한 수렴성 분석 (Convergence Analysis of Kinematic Parameter Calibration for a Car-Like Mobile Robot)

  • 유광현;이국태;정창배;정우진
    • 제어로봇시스템학회논문지
    • /
    • 제17권12호
    • /
    • pp.1256-1265
    • /
    • 2011
  • Automated parking assist systems are being commercialized and rapidly spread in the market. In order to improve odometry accuracy, we proposed a practical odometry calibration scheme of Car-Like Mobile Robot (CLMR). However, there were some open problems in our prior work. For example, it was not clear whether the kinematic parameters always converged or not using the proposed calibration scheme. In addition, test driving had to be carried out "twice" without detailed explanation. This research aims to provide answers for the addressed questions though the convergence property analysis of the calibration scheme. In this paper, we evaluate on the effect of the kinematic parameter error on the odometry error at the final pose by numerical computation. The evaluation will show that the wheel diameter and tread of the CLMR can be calibrated by iterative test drives. In addition, the region of convergence in the parametric space will be discussed. Presented experimental results clearly showed that the proposed calibration scheme would be useful in practical applications.

Study on Optimal Calibration Configurations of a Parallel Type Machining Center Under a Single Planar Constraint

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1886-1893
    • /
    • 2003
  • This paper examines the parameter observability of a calibration system that consrains a mobile platform to a planar table to take the calibration data. To improve the parameter observability, we find the optimal configurations providing the calibration with maximum contribution. The QR-decomposition is used to compute the optimal configurations that maximize the linear independence of rows of an observation matrix. The calibration system is applied to the parallel type manipulator constructed for a machining center. The calibration results show that all the necessary kinematic parameters assigned in a Stewart-Gough platform are identifiable and convergent to desirable accuracy.

로보트 accuracy향상을 위한 kinematic identification (Kinematic Iidentification for Improving Robot Accuracy)

  • 조선휘;김문상;김귀식;장현상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.131-137
    • /
    • 1989
  • The effect of kinematic model choice on robot calibration is examined. This paper presents a complete formulation to identify the actual robot kinematic parameters directly from position data. The method presented in this paper applies to any serial link manipulator with arbitrary order and combination of revolute and prismatic joint.

  • PDF

로봇 캘리브레이션을 위한 모델 파라미터의 관측성 연구 (A Study on Observability of Model Parameters for Robot Calibration)

  • 범진환;양수상;임생기
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.64-71
    • /
    • 1997
  • Objective of calibration is to find out the accurate kinematic relationships between robot joint angles and the position of the end-effector by estimating accurate model parameters defining the kinematic function. Estimating the model parameters requires measurement of the end-effector position at a number of different robot configurations. This paper studies the implication of measurement configurations in robot calibration. For selecting appropriate measurement configurations in robot calibration, an index is defined to measure the observability of the model parameters with respect to a set of robot configurations. It is found that, as the observability index of the selected measurement configurations increase the attribution of the position errors to the parameter errors becomes dominant while the effects of the measurement and unmodeled errors are less significant; consequently better estimation of parameter errors is expected. To demonstrate the implication of the observability measure in robot calibration, computer simulations are performed and their results are discussed.

  • PDF

공간오차 측정을 통한 6자유도 병렬기구의 보정 (Calibration of 6-DOF Parallel Mechanism Through the Measurement of Volumetric Error)

  • 오용택;아궁 샴수딘 사라기;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.48-54
    • /
    • 2012
  • This paper introduces the kinematic calibration method to improve the positioning accuracy of a parallel mechanism. Since all the actuators in the parallel mechanism are controlled simultaneously toward the target position, the volumetric errors originated from each motion element are too complicated. Therefore, the exact evaluation of the error sources of each motion element and its calibration is very important in terms of volumetric errors. In the calibration processes, the measurement of the errors between commands and trajectories is necessary in advance. To do this, a digitizer was used for the data acquisition in 3 dimensional space rather than arbitrary planar error data. After that, the optimization process that was used for reducing the motion errors were followed. Consequently, Levenberg-Marquart algorithm as well as the error data acquisition method turned out effective for the purpose of the calibration of the parallel mechanism.

병렬기구형 틸팅 테이블의 보정에 관한 연구 (Study on Calibration for Parallel-Typed Tilting Table)

  • 김태성;정진욱;김용희;박근우;이민기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1512-1517
    • /
    • 2003
  • This paper presents the calibration for the parallel typed tilting table. The calibration system needs only simple sensing device which is a digital indicator to measure the orientation of a table. The calibration algorithm is developed by a measurement operator. It eliminates the concern about the poor parameter observability due to a large number of parameters of parallel-mechanism. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a Parallel-typed Tilting Table and all the necessary kinematic parameters are identifiable.

  • PDF

화상정보를 이용한 로봇기구학의 오차 보정 (The compensation of kinematic differences of a robot using image information)

  • 이영진;이민철;안철기;손권;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1840-1843
    • /
    • 1997
  • The task environment of a robot is changing rapidly and task itself becomes complicated due to current industrial trends of multi-product and small lot size production. A convenient user-interfaced off-line programming(OLP) system is being developed in order to overcome the difficulty in teaching a robot task. Using the OLP system, operators can easily teach robot tasks off-line and verify feasibility of the task through simulation of a robot prior to the on-line execution. However, some task errors are inevitable by kinematic differences between the robot model in OLP and the actual robot. Three calibration methods using image information are proposed to compensate the kinematic differences. These methods compose of a relative position vector method, three point compensation method, and base line compensation method. To compensate a kinematic differences the vision system with one monochrome camera is used in the calibration experiment.

  • PDF

Complete Parameter Identification of Gough-Stewart platform with partial pose measurements using a new measurement device

  • Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.825-830
    • /
    • 2004
  • Kinematic calibration of Gough-Stewart platform using a new measurement device is presented in this paper. The device simultaneously measures components of position and orientation using commercially available gadgets. Additional kinematic parameters are defined to model the sources of inaccuracies for the proposed measurement device. Computer simulations reveal that all kinematic parameters of the Gough-Stewart platform and the additional kinematic parameters of the measurement device can be identified with the partial pose measurements of the device. Results also show that identification is robust for the initial errors and the noise in measurements. The device also facilitates the automation of easurement procedure.

  • PDF

병렬구조 로봇의 보정을 위한 보정 가능 변수 판별과 최적 자세 선정에 관한 연구 (Study on the Identifiable Parameters and Optimum Postures for Calibrating Parallel Manipulators)

  • 박종혁;김성관;압둘라우프;류제하
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1476-1481
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type parallel manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF