• 제목/요약/키워드: kVp test

Search Result 115, Processing Time 0.025 seconds

Study on the Distribution of Vibrio parahaemolyticus along Cheju Coast (제주연안해역의 Vibrio parahaemolyticus 분포에 관한 연구)

  • Song, Min-Kyoung;Kim, Man-Chul;Heo, Moon-Soo
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.1
    • /
    • pp.34-41
    • /
    • 2007
  • A study on the distribution of V. parahaemolyticus among sea water, sea mud, and marine products in Hwabuk, Samyang, Daepo, Jungmun, Pyoson, Anduk, Aewol, and Gwakji on the coastal area of Jeju island was conducted from January to December in 2002. The 2,880 total specimens of 960 sea waters, 960 sea mud, 960 marine products were collected and studied for the rate of isolation of V. parahaemolyticus, and biochemical, serological and antibiotic sensitivity tests were performed. A total of 417 strains of V. parahaemolyticus were isolated and identified from 2,880 total specimens. In the test of biochemical properties, 100 of V. parahaemolyticus isolates in the presence of 0.85% NaCl were positive in the utilization of lysine, ornithine, indole, glucose, and mannitol, and negative in the utilization of ONPG, arginine, sodium citrate, urea, tryptophane, inositol, sorbitol, rhamnose, sucrose, and melibiose, $H_2S$ production and VP reaction, while positive or negative in gelatin liquefaction and utilization of amygdalin or arabinose. The isolation rates to the specimen were 161 strains (16.8%) from 960 of sea waters, 137 strains (14.3%) from 960 of sea mud, and 119 strains (12.4%) from 960 of marine products. The isolation rates of V. parahaemolyticus from 8 coastal areas were 14.4% (52/360) in Hwabuk area, 15.3% (55/360) in Samyang area, 13.6% (49/360) in Daepo area, 18.3% (66/360) Jungmun area, 13.1% (47/360) in Pyosun area, 16.4% (59/360) in Anduk area, 12.5% (45/360) in Aewol area and 12.2% (44/360) in Gwakji area, respectively. The distribution of 417 V. parahaemolyticus, isolates was high at Jungmun with 18.3% (66/360), and from sea water with 16.8% (161/960).

A Study on the Effect of FFF 3D Printer Nozzle Size and Layer Height on Radiation Shield Fabrication (FFF방식의 3D프린터 노즐 크기와 층 높이가 방사선 차폐체 제작에 미치는 영향에 관한 연구)

  • Yoon, Joon;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.891-898
    • /
    • 2020
  • As the problem of shields made of lead has recently emerged, research on replacement shields is essential, and studies on the manufacture of diagnostic X-ray shields with 3D printers are also being actively conducted. Recently, with the development of metal mixed filaments, it has become possible to manufacture shielding materials easily, but studies on the nozzle size and output setting of 3D printers are insufficient. Therefore, this study aims to compare and analyze the results through a shielding rate experiment using a brass filament and a 3D printer, outputting the shield according to the nozzle size and layer height, and using a diagnostic radiation generator. The nozzle size was changed to 0.4, 0.8 mm, layer height 0.1, 0.2, 0.3, 0.4 mm, and output. The shielding rate test was fixed at 40 mAs, and the shielding rate was analyzed by experimenting with 60, 80, and 100 kVp, respectively. As a result of the analysis, it was analyzed that the printing time could be reduced to 1/10 according to the nozzle size and the layer height, and the shielding rate could be increased by 1% or more.

Comparison of Heel Effect with Distance and Direction Change (거리와 방향 변화에 따른 힐이팩트 비교)

  • Kim, Hyung-Woo;Seok, Ji-Eun;Kang, Min-Yeong;Jo, Chan-Haeng;Jeon, Min-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.435-442
    • /
    • 2022
  • The heel effect creates a density difference in the X-ray images because the intensity of the anode and cathode side of the X-ray tube is not equal. The purpose of this study is to evaluate the density difference due to the heel effect by rotating the step wedge by 180 degrees and then changing the distance. After fixing the tube voltage and tube current to 72 kVp and 10 mAs, the forward and reverse directions were taken using a step wedge. At this time, the distance (80 cm ~ 130 cm) was taken at 10 cm intervals, and the density value was measured by setting the region of interest for each step of the step wedge through the M6 program. First, the difference in intensity between the anode and the cathode was confirmed through the radiation exposure test. In addition, when the distance (from 80 cm to 130 cm) was changed, the difference in density between the cathode and the anode decreased as the projection distance increased. As a result, images of uniform density can be obtained as the projection distance increases.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test (PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석)

  • Kim, Myungsoo;Kim, Giyoon;Lee, Minju;Kang, Dong-uk;Lee, Daehee;Park, Kyeongjin;Kim, Yewon;Kim, Chankyu;Kim, Hyoungtaek;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Resistance of Vibrio parahaemolyticus Against the Environmental Factors (Vibrio parahaemolyticus의 환경인자(環境因子)에 대(對)한 저항성(抵抗性))

  • Kim, Sang-Chual;Kim, Doo-Hie;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.183-194
    • /
    • 1988
  • This study was carried out to investigate for resistance of V. parahaemolyticus that isolated from patients of food poisoning and fish and shellfish, captured in east coast of Kyungpook province of Korea from 1985 to 1986. VP ATCC 17802 and NAG V. ATCC 6538 were used as control. In fish, shellfish and seaweed, the more temperature increased, the shorter survival time was. In case of sea-water, the more temperature rose up, the longer survival time was, particularly in $37^{\circ}C$ and $25^{\circ}C$, the strains had survived after 6 months. And in tapwater, it was sterilized in 150 mins. and survived for 11.5 days on maximum in ground water. In kimchi, at room temperature, germicidal time was shorter more than 6 times compared with that which had been kept in refrigerator. It survived for 57.1 days in milk, 49.2 mins. in yougurt. Strains had been surviving in frozen condition at $-70^{\circ}C$ even after 6 months, present study time. In resistance test in water bath at several degrees of temperature, all the strains were sterilized in 20 mins. with $60^{\circ}C$. In resistance test to driness, number of surviving strains dropped rapidly in 10-11%) water contents. In UV $2538{\AA}$, strains were sterilized in 20 mins. In resistance test to alcohol, strains had survived for 0.1-4 mins. in fermentative wine of below than 25% and distilled wine of over than 25% in alcohol concentration. The bactericidal concentration of disinfectant was 1% in phenol and 3% in cresol. In 0.1M acetic acid and 0.1M lactic acid, number of surviving colonies decreased rapidly but not in citric acid. The more NaCl concentration rose up, the lower decreasing rate of number of surviving colonies was. The strains had showed sensitive response to vancomycin, chloramphenicol, gentamicin, and resisted to carbenicillin, ampicillin and kanamycin. When one day culture strain was cultured till 25th day, resistant strains to tetracycline and cephalothin were changed to sensitive.

  • PDF

Data Analysis of Suspension P-S Velocity Logging in Banded Gneiss Area around Hanam, Gyeonggi Province (경기도 하남시 인근 호상편마암 지역에서 Suspension P-S 속도검층 자료분석)

  • Yu, Young-Chul;Song, Moo-Young;Leem, Kook-Mook
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.623-631
    • /
    • 2007
  • In this paper, dynamic elastic module of banded gneiss were calculated on the basis of SPS velocity logging data obtained from a geotechnical test-hole in Pungsan-dong, Hanam, Gyeonggi Province, Korea. This study mainly focuses on the velocity analysis, Q factor calculation relative to attenuation factor, and generation of crack information and its relation with seismic velocity. As a result, P-wave and S-wave velocity of fresh hard rock was 5,559m/s and 3,063m/s, respectively, with Poisson's ratio being 0.28. With these results, dynamic modules were prepared, and crack information analyzed by acoustic televiewer was incorporated to identify the correlation among and between delay of first arrival by crack amplitude ratio, and velocity. The results of this study revealed that the analyzed logging hole mainly consisted of micro crack and a number of cracks and the size of crack aperture, functioned as a variable to seismic velocity in the micro crack area of this type of hard rock.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.