• 제목/요약/키워드: kVA rating

검색결과 28건 처리시간 0.025초

Effect of Winding Configuration on the kVA Rating of Wye-connected Autotransformer Applied to 12- pulse Rectifier

  • Meng, Fangang;Du, Qingxiao;Gao, Lei;Li, Quanhui;Man, Zhongcheng
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.463-474
    • /
    • 2019
  • This paper presents the effect of winding configuration on the kVA rating of a wye-connected autotransformer applied to a 12-pulse rectifier. To describe the winding configuration of the wye-connected autotransformer, position and proportional parameters are defined and their quantitative relation is calculated. The voltages across and currents through the windings are measured under different winding connections. Consequently, a relation between the kVA rating and position parameter is established in accordance with the analysis, and the optimal winding configuration is obtained on the basis of this relation. A wye-connected autotransformer with the least equivalent kVA rating and simplest winding configuration is designed and applied to the 12-pulse rectifier. Simulations and experiments are conducted to validate the theoretical analysis.

신용등급전이행렬의 경험적 베이지안 추정과 비교 (Empirical Bayes Estimation and Comparison of Credit Migration Matrices)

  • 김성철;박지연
    • 응용통계연구
    • /
    • 제22권3호
    • /
    • pp.443-461
    • /
    • 2009
  • 신용전이행렬을 추정함에 있어서 국내의 등급전이자료의 축적이 부족한 점을 극복하기 위하여 외국의 신용평가기관(무디스)의 전이행렬자료와 국내의 신용등급 부여자료를 이용하여 경험적 베이지안 추정방법에 의한 전이행렬을 도출하고, 이 전이행렬을 다른 전이행렬과 비교해보기 위하여 전이행렬의 동적인 요소를 평균전이확률의 개념으로 표시할 수 있는 특성척도를 개발하여 신용전이행렬의 시계열 특성과 통계적 특성을 비교한다. 시계열자료의 척도는 베이지안 추정행렬이 안정적임을 보여주는 반면 국내 행렬은 시간적으로 변화의 폭이 크고 무디스나 베이지안 행렬보다 상대적으로 인접전이의 비율이 높게 나타났다. 붓스트랩 검정을 통하여 세 가지 추정방법이 통계적으로 유의한 차이가 있음을 보이고 베이지안 행렬이 무디스 자료보다는 국내자료에 더 많은 영향을 받았음을 유추할 수 있다. 신용등급 전이에 따른 포트폴리오의 가치변화를 고려하는 몬테칼로 시뮬레이션을 통하여 신용 VaR를 구하여 비교하였다. 국내 전이행렬의 경우에 평균은 가장 크고 신용위험도 가장 큰 값을 보였다. 시뮬레이션에서도 베이지안 추정에 의한 결과가 국내자료에 의한 결과와 더 가깝다는 것을 알 수 있다.

Series Hybrid Active Filter

  • 김원호;김종수;강유리;임근회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 1995
  • Hybrid active filters utilize passive filters to reduce the voltage rating and hence the VA rating of the active filter converter. A novel hybrid active filter topoloty to minimize utility current harmonics at high power levels is presented in this paper. The proposed topology combines both passive and active filters to obtain the lowest converter VA rating as compared to the converter rating in the active filter and the series-active hybrid filter configurations. This is demonstrated with experimental results from a laboratory model. Simulation results showing the effect of passive filter impedance are presented.

  • PDF

새로운 양방향 지능형 반도체 변압기의 동작과 성능 분석 (Operation and Performance Analysis of New Bidirectional Intelligent Semiconductor Transformer)

  • 김도현;이병권;한병문;이준영;최남섭
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2013
  • This paper proposes a new configuration of bidirectional intelligent semiconductor transformer with rating of 1.9kV/127V, 2kVA. The proposed transformer consists of high-voltage high-frequency AC-DC rectifier, and low-voltage DC-DC and DC-AC converters. The operational feasibility of proposed transformer was verified by computer simulation with PSCAD/EMTDC software. Based on the simulation results, a hardware prototype with rating of 1.9kV/127V, 2kVA was built and tested in the lab to confirm the feasibility of hardware implementation. Using three units of this transformer, a 3-phase transformer with rating of 3.3kV/220V, 6kVA can be built.

전류형/전압형 컨버터를 이용한 대전력 하이브리드시스템용 출력필터 구조 연구 (A Study of Output Filter Design for Current/Voltage Source Converter in High-Power Hybrid System)

  • 김태식;곽상신;권우현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.228-230
    • /
    • 2009
  • 본 논문에서는 전류형 인버터(CSI)와 전압형 인버터(VSI)를 조합하여 유도성 부하에 정현파 전류를 공급하는 시스템에서, LC 소자를 추가함으로써 전압형 인버터의 VA rating을 줄일 수 있는 방법을 제안하였다. 전력제어용 스위칭 소자인 SCR은 대용량인 장점이 있는 반면에 턴오프 제어가 되지 않고, 비선형 특성으로 인해 고조파가 발생한다. 이러한 단점을 개선하기 위해 전압형 인버터를 사용하여, SCR를 OFF하고 부하에 정현파 전압/전류를 제공한다. 또한, 출력단에 수동 LC 필터를 추가하여 전압원 인버터의 VA rating을 저감시키는 구조를 연구하고 이를 Psim을 이용한 시뮬레이션을 통해 검증하였다.

  • PDF

30kVA 주상 변압기의 정격부하에 의한 열분포에 관한 연구 (A Study on the Thermal distribution of the 30kVA Pole Transformer Due to the Rated load)

  • 김민규;김정태;구자윤;송기동;조연옥;하복남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 1991
  • The life of the transformers is significantly dependent upon the rate of thermal deterioration in the employed insulating materials. Therefore, the study should be based on hot-spot temperature considerations for the life expectancy and possible overload of transformer. We have measured directly temperature of the winding using thermocouples and these test results are compared with those obtained from computer simulation. In this work, our fundamental investigations are well described for the analysis in the thermal distribution of the oil-immersed transformer with the rating of 30kVA.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

새로운 고전압 대전력용 24펄스 다이오드 정류기 시스템 (A New 24-Pulse Diode Rectifier for High Voltage and High Power Application)

  • 최세완;김기용
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.304-309
    • /
    • 1999
  • 본 논문에서는 새로운 24펄스 다이오드 정류기 시스템을 제안한다. 제안하는 다이오드 정류기 시스템은 기존의 직렬형 12펄스 다이오드 정류기에 수동의 보조회로를 추가함으로서 구성되어지고, 입력전류는 제 22차까지의 고조파가 제거되어 거의 정현파에 가까운 전류 파형을 얻는다. 또한, 출력 전압은 n=24k, k=1,2,3... 의 고조파 성분을 갖는 24펄스 특성를 나타낸다. 더욱이, 이 보조회로의 용량은 출력용량에 비하여 매우 작으며, 능동 스위칭소자를 사용하지 않으므로 외란에 강하고 구현이 간단하다. 따라서, 본 방식은 중·대용량급의 고전압 비제어(uncontrolled) 직류전원이 필요한 인버터나 무정전 전원장치등의 앞단에서 입력고조파의 저감에 경제적이고 효율적이다. 220V, 3KVA 정류기 시스템의 실험을 통하여 제안한 시스템의 타당성을 검증하였다.

  • PDF

Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems

  • Kim, Sangsoon;Jahng, Seungmin;Yu, Kyung-Ho;Lee, Byung-Chul;Kang, Yeonwook
    • 대한치매학회지
    • /
    • 제17권3호
    • /
    • pp.100-109
    • /
    • 2018
  • Background and Purpose: Although the clock drawing test (CDT) is a widely used cognitive screening instrument, there have been inconsistent findings regarding its utility with various scoring systems in patients with mild cognitive impairment (MCI) or dementia. The present study aimed to identify whether patients with MCI or dementia exhibited impairment on the CDT using three different scoring systems, and to determine which scoring system is more useful for detecting MCI and mild dementia. Methods: Patients with amnestic mild cognitive impairment (aMCI), vascular mild cognitive impairment (VaMCI), mild Alzheimer's disease (AD), mild vascular dementia (VaD), and cognitively normal older adults (CN) were included. All participants were administered the CDT, the Korean-Mini Mental State Examination (K-MMSE), and the Clinical Dementia Rating scale. The CDT was scored using the 3-, 5-, and 15-point scoring systems. Results: On all three scoring systems, all patient groups demonstrated significantly lower scores than the CN. However, while there were no significant differences among patients with aMCI, VaMCI, and AD, those with VaD exhibited the lowest scores. Area under the Receiver Operating Characteristic curves revealed that the three CDT scoring systems were comparable with the K-MMSE in differentiating aMCI, VaMCI, and VaD from CN. In differentiating AD from CN, however, the CDT using the 15-point scoring system demonstrated the most comparable discriminability with K-MMSE. Conclusions: The results demonstrated that the CDT is a useful cognitive screening tool that is comparable with the Mini-Mental State Examination, and that simple CDT scoring systems are sufficient for differentiating patients with MCI and mild dementia from CN.

50[kVA] 몰드변압기 권선부의 열전달 특성 해석 (Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer)

  • 이현진;정중일;허창수;조한구
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.47-54
    • /
    • 2002
  • 본 논문은 단상 50[kVA] 몰드변압기 권선부의 열전달 특성에 대한 연구 결과이다. 1차 권선의 열전도도는 권선을 이루고 있는 물질 비 즉, 1차 권선의 절연을 담당하는 다량의 에폭시 수지와 그에 비해 소량의 구리 도선을 고려하여 결정하였다. 반면에 2차 권선의 경우 구성 성분은 다량의 구리도선과 절연을 담당하는 소량의 에폭시 수지로 되어 있다. 2차 권선 열전도도는 질량 비로서 결정될 수 없기 때문에 2차 권선의 열전도도값은 시작품의 측정 최고온도와 FEM을 이용한 분석결과를 비교하여 결정하였다. 각 권선부의 물리적 특징을 고려하여 상용 프로그램을 통해 시뮬레이션 모델을 만들었다. 본 연구결과를 바탕으로 몰드변압기 권선부에 Hole이 존재할 때와 안할 때 각각에 대해 주위온도·풍속변화에 따른 최고온도 변화를 고찰하였다.