• Title/Summary/Keyword: k-out-of-n system

Search Result 979, Processing Time 0.025 seconds

A Study on the Evaluation of Long Term Stability of Brinell Standard Hardness Tester and Automatic Indentation Measurement System and Optimum Test Condition (브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung;Hwang, N.M.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.10-15
    • /
    • 2000
  • Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is $30{\mu}m/s$ of load application speed and 25 seconds of load application time.

  • PDF

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

Composition of Optimal Nutrient Solution for Single-stemmed Rose 'Red velvet' in a Closed Aeroponic System

  • Kang Mu Jang;Lee Joo Hyun;Lee Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Experiments were carried out to develop an optimal nutrient solution for the single-stemmed rose (Rosa hybrida L.) 'Red velvet' in a closed aeroponic system. Plants were grown in 1/3, 1/2, 1, or 3/2 strength of the nutrient solution of National Horticultural Research Station in Japan (NHRS). Significantly less changes of pH and EC ($dS{\cdot}m^{-1}$) in the drainage were observed in 1/2 strength treatment as compared to other treatments. The $NO_3-N$, K, Ca, and Mg concentrations in the drainage solution of 1/2 strength treatment were maintained at optimal levels. These results indicated that the rose uptakes of both nutrients and water was more stable than those in other concentration. The concentration of macronutrients in nutrient solution were adjusted based on the ratio of nutrient:water (n/w) taken up by plants grown in the 1/2 strength solution. The composition of the new solution (classified the University of Seoul (UOS) solution) was as follow; $NO_3-N$ 8.8, $NH_4-N$ 0.67, P 2.0, K 4.8, Ca 4.0, Mg 2.0 $me{\cdot}L^{-1}$. To further evaluate new solution on crop growth, the rose 'Red Velvet' was grown again in l/2, 1, and 2 strength UOS solution to compare with 1.0 strength PBG (proefstion voor bloemisterij en glasgroenpe) solution. Overall the plant growth, including the stem length and number of five-leaflet leaves was higher in 1.0 strength of UOS solution than other treatments. Results presented in this study indicate that the nutrients in the UOS solution are well balanced for the single-stemmed rose in the closed aeroponic system.

Basic Design and Performance Analysis of an Solar Absorption Chiller (태양열 구동 흡수식 냉동기의 기본설계 및 성능분석)

  • Baek, N.C.;Yoon, E.S.;Joo, M.C.;Jeong, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.107-112
    • /
    • 1998
  • Basic design of a solar driven absorption cooling machine(SDACM) with a cooling capacity of 5 USRT was carried out. The SDACM is a single effect cycle driven by low temperature hot water from solar collectors. The SDACM design data were calculated by the steady state simulation program which was developed in this study The variation of COP and cooling capacity of the SDACM were investigated at different off-design conditions. Both the cooling capacity and the system COP were improved with decreasing cooling water temperature. If hot water temperature was increased, the cooling capacity was improved but the system COP was found to be decreased. The decrease of the system COP were basically caused by increased thermal loads in the system components.

  • PDF

Calculation of Land Category Area and Pollution Loads according to Real Land Usage using High Resolution Satellite Image (고해상도 영상자료를 이용한 실제토지이용에 따른 지목면적 및 부하량 산정)

  • Park, Jae Hong;Lee, Su Woong;Park, Ju Hyun;Rhew, Doug Hee;Jung, Dong Il;Choi, Hye Mi;Jeon, Woo Song
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.193-204
    • /
    • 2009
  • The study was conducted investigation on land of D-dong in N city which is an urban area and D myeon of N city which is a suburban area, based on high resolution satellite image, to find out actual land usage. As for D-dong in N city, different rate between actual usage and official land information was 0.5~4.8% in terms of 5 major land types (paddy field, farm, ground, forest, and others). D myeon in N city posted 1.4~8.4%, which is higher than that of its counterpart. As for unit load, "land" which is large in terms of load presented a big difference between official information and actual usage. On the other hand, the levels of paddy, field, forest and others posted only small changes in load. In case of T-P, in particular, unit of each land type is lower than BOD and T-N, showing almost no changes in pollution loads.

PERFORMANCE ANALYSIS OF AAL MULTIPLEXER WITH CBR TRAFFIC AND BURSTY TRAFFIC

  • Park, Chul-Geun;Han, Dong-Hwan
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.1
    • /
    • pp.81-95
    • /
    • 2001
  • This paper models and evaluates the AAL multiplexer to analyze AAL protocol in ATM networks. We consider an AAL multiplexer in which a single periodically determinsitic CBR traffic stream and several variable size bursty background traffic streams are multiplexed and one ATM cell stream goes out. We model the AAL multiplexer as a B/sup X/ + D/D/1/K queue and analyze this queueing system. We represent various performance measures such as loss probability and waiting time in the basis of cell and packet.

Water Lubrication System Supported by High-density Hydrophilic Polymer Brush

  • Kobayashi, Motoyasu;Ishihara, Kazuhiko;Takahara, Atsushi;Suzuki, Atsushi;Kaido, Masataka;Zhe, Wang
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.343-343
    • /
    • 2006
  • Surface-initiated atom transfer radical polymerization of 2-methacryloyloxyethyl phosphorylcholine (MPC) was carried out to produce high-density poly(MPC) brush on silicon wafer. Frictional properties of poly(MPC) was investigated by by sliding a glass ball (${\phi}\;10\;nm$) on the substrates over a distance of 20 mm at a sliding velocity of 90 mm/min under loading of 0.49 N at 298 K. Higher friction coefficients were observed in dry N2 atmosphere and in toluene condition, whereas the friction coefficients decreased to 0.02 in humid air and in water. It is supposed that water-swollen poly(MPC) brush works as a lubricant to moderate the interaction between brush and probe.

  • PDF

Development of CNT-dispersed Si3N4 Ceramics by Adding Lower Temperature Sintering Aids

  • Matsuoka, Mitsuaki;Yoshio, Sara;Tatami, Junichi;Wakihara, Toru;Komeya, Katsutoshi;Meguro, Takeshi
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.4
    • /
    • pp.333-336
    • /
    • 2012
  • The study to give electrical conductivity by dispersing carbon nanotubes (CNT) into silicon nitride ($Si_3N_4$) ceramics has been carried out in recent years. However, the density and the strength of $Si_3N_4$ ceramics were degraded and CNTs disappeared after firing at high temperatures because CNTs prevent $Si_3N_4$ from densification and there is a possibility that CNTs react with $Si_3N_4$ or $SiO_2$. In order to suppress the reaction and the disappearance of CNTs, lower temperature densification is needed. In this study, $HfO_2$ and $TiO_2$ was added to $Si_3N_4-Y_2O_3-Al_2O_3$-AlN system to fabricate CNT-dispersed $Si_3N_4$ ceramics at lower temperatures. $HfO_2$ promotes the densification of $Si_3N_4$ and prevents CNT from disappearance. As a result, the sample by adding $HfO_2$ and $TiO_2$ fired at lower temperatures showed higher electrical conductivity and higher bending strength. It was also shown that the mechanical and electrical properties depended on the quantity of the added CNTs.

A Study on the Sanitation Management Status and Barriers to HACCP System Implementation of School Foodservice Institutions in Seoul Metropolitan Area (수도권 지역 학교급식소의 위생관리 현황 및 HACCP 시스템 적용 장애요인 연구)

  • Kim, Gyoung-Mi;Lee, Sim-Yeol
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.3
    • /
    • pp.405-417
    • /
    • 2008
  • The purpose of the study was to investigate the sanitation management status and implementation barriers of the HACCP system. A survey was conducted based on 760 schools through e-mail after having gone through phone interviews to dieticians in Seoul, Gyeonggi and Incheon areas from December 2006 to March 2007. The following statistics were drawn out from the 459 surveys out of the 760, thus giving a response rate of 60.4% (N = 459). The statistical data analysis was completed using the SPSS program. 92.6% of the respondents operated sanitary education once a month and 67.1 % used internet as their sanitary educational source. 50.5% of the pre-preparation rooms were not divided and 78.0% of kitchen floors were always kept wet. Only 15.7% of the respondents used heat and cold insulators and 73.2% of drinking water was natural or purified water. 60.3% of food trays were electronically sterilized and 70.2% of spoons and chopsticks were sterilized by boiling water. The main cause of food-borne diseases was the lack of facilities and equipment (33.1%). Also, the deficiency of facilities and equipment (4.07 points) acted as an implementation barrier of the HACCP system. Compared to Gyeonggi or Incheon area results, Seoul's facilities and equipment (p < 0.001) and implementing barriers of the HACCP system (p < 0.001) results came out relatively high. After the analysis of the implementation barriers of the HACCP system, 91.7% of school principals said it was difficult to apply the HACCP system due to lack of financial support. In consideration to the school foodservice support, solutions for the facilities of school foodservice and a systematic sanitary education of the HACCP system must be made for the employees and everyone else who are related.