• Title/Summary/Keyword: k-dose

Search Result 15,356, Processing Time 0.04 seconds

Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan (안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가)

  • Moon, Se-Young;Hong, Sang-Woo;Seo, Ji-Sook;Kim, Yeong-Beom;Kwak, Wan-Sin;Lee, Seong-Yeong;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

Efficacy of Low Dose Barbiturate Coma Therapy for the Patients with Intractable Intracranial Hypertension Using the $Bispectral^{TM}$ Index Monitoring

  • An, Hung-Shik;Cho, Byung-Moon;Kang, Jeong-Han;Kim, Moon-Kyu;Oh, Sae-Moon;Park, Se-Hyuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.4
    • /
    • pp.252-257
    • /
    • 2010
  • Objective : Barbiturate coma therapy (BCT) is a useful method to control increased intracranial pressure (IICP) patients. However, the complications such as hypotension and hypokalemia have caused conditions that stopped BCT early. The complications of low dose BCT with $Bispectral^{TM}$ index (BIS) monitoring and those of high dose BCT without BIS monitoring have been compared to evaluate the efficacy of low dose BCT with BIS monitoring. Methods : We analyzed 39 patients with high dose BCT group (21 patients) and low dose BCT group (18 patients). Because BIS value of 40-60 is general anesthesia score, we have adjusted the target dose of thiopental to maintain the BIS score of 40-60. Therefore, dose of thiopental was kept 1.3 to 2.6 mg/kg/hour during low dose BCT. However, high dose BCT consisted of 5 mg/kg/hour without BIS monitoing. Results : The protocol of BCT was successful in 72.2% and 38.1% of low dose and high dose BCT groups, respectively. The complications such as QT prolongation, hypotension and cardiac arrest have caused conditions that stopped BCT early. Hypokalemia showed the highest incidence rate in complications of both BCT. The descent in potassium level were $0.63{\pm}0.26$ in low dose group, and $1.31{\pm}0.48$ in high dose group. The treatment durations were $4.89{\pm}1.68$ days and $3.38{\pm}1.24$ days in low dose BCT and high dose BCT, respectively. Conclusion : It was proved that low dose BCT showed less severe complications than high dose BCT. Low dose BCT with BIS monitoring provided enough duration of BCT possible to control ICP.

A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities (콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구)

  • Ji, Tae-Jeong;Kwak, Byung-Joon;Min, Byung-In
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

Toxicity Study of Red Ginseng Acidic Polysaccharide (RGAP) : Single and 2-week Repeated Oral Dose Toxicity Study in Rats

  • Park, Jong-Dae;Song, Yong-Bum;Kwak, Yi-Seong;Kim, Jong-Choon;Im, Doo-Hyun;Junghee Han
    • Toxicological Research
    • /
    • v.19 no.3
    • /
    • pp.173-180
    • /
    • 2003
  • The present study was conducted to investigate the single and 2-week repeated dose toxicity of red ginseng acidic polysaccharide (RGAP) in Sprague-Dawley rats. The test article was administered orally to rats at dose levels of 0, and 2000 mg/kg/day for single dose toxicity study and at dose levels of 0, 250, 500, and 1000 mg/kg/day for repeated dose toxicity study. In both studies, there were no treatment-related effects on mortality, clinical signs, food and water consumption, ophthalmoscopy, urinalysis, hematology, serum biochemistry, necropsy findings and organ weights of all animals treated RGAP. Based on these results, it was concluded that the 2-week repeated oral dose of RGAP may have no toxic effect in rats at a dose level of 1000 mg/kg/day. In the condition of this study, the no-observed-adverse-effect level (NOAEL) was considered to be 1000 mg/kg/day for both sexes.

Comparison of Dose Measurement of Glass Dose Meter, Semiconductor Dose Meter, and Area Dose Meter in Diagnostic X-ray Energy (진단영역 X선 에너지에서 유리선량계, 반도체선량계, 면적선량계의 선량 실측 비교)

  • Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.483-489
    • /
    • 2019
  • This paper obtained and compared these dose values by setting and comparing the X-ray imaging conditions (tube voltage 60 kVp, 70 kVp, 80 kVp, tube current 10 mAs, 16 mAs and X-ray field size are 10 × 10 cm, 15 × 15 cm). Each dose value was measure 10 times and represented as an average value. The purpose of this experiment is to serve as a reference for the X-ray exposure of diagnostic areas according to the type of dosimeter and to help with another dose measurement. The results of the experiment showed very little difference between the glass dosimeter(GD) and semiconductor dosimeter values due to changes in tube voltage of 60, 70, 80 kVp, regardless of field sized, but for dose area product(DAP), the difference in dose value was significant according to field size.

Single and Two-Week Repeated] Oral Dose Toxicity Study of DHP2, a Hydrophobic Drug Delivery Vehicle in Mice

  • Han, Jung-Hee;Chung, He-Sson;Lee, Jong-Hwa;Suh, Jeong-Eun;Lee, Gab-Soo;Kim, Jong-Choon;Kang, Boo-Hyon
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.123-129
    • /
    • 2004
  • The present study was conducted to investigate the single and 2-week repeated dose toxicity of DHP2, a hydrophobic drug delivery vehicle, in ICR mice. The test article was administered orally to mice at the dose levels of 2.5, 12.5 and 37.5 g/kg for single dose toxicity study and at the dose levels of 0, 2.5, 5, and 10 g/kg for repeated dose toxicity study. In both studies, there were no treatment-related effects on mortality, clinical signs, food and water consumption, ophthalmoscopy, urinalysis, hematology, serum biochemistry, necropsy findings and organ weights of all animals treated DHP2. Based on these results, it was concluded that the 2-week repeated oral dose of DHP2 may have no toxic effect in mice at a dose level of 10 g/kg. In the condition of this study, the no-observed-adverse-effect level (NOAEL) was considered to be 10 g/kg/day for both sexes.

Surface Treatment of Eggshells with Low-Energy Electron Beam

  • Kataoka, Noriaki;Kawahara, Daigo;Sekiguchi, Masayuki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Background: Salmonella enteritidis (SE) was the main cause of the pandemic of foodborne salmonellosis. The surface of eggs' shells can be contaminated with this bacterium; however, washing them with sodium hypochlorite solution not only reduces their flavor but also heavily impacts the environment. An alternative to this is surface sterilization using low-energy electron beam. It is known that irradiation with 1 kGy resulted in a significant 3.9 log reduction (reduction factor of 10,000) in detectable SE on the shell. FAO/IAEA/WHO indicates irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard. On the other hand, the Food and Drug Administration has deemed a dose of up to 3 kGy is allowable for eggs. However, the maximum dose permitted to be absorbed by an edible part (i.e., internal dose) is 0.1 Gy in Japan and 0.5 Gy in European Union. Materials and Methods: The electron beam (EB) depth dose distribution in the eggshell was calculated by the Monte Carlo method. The internal dose was also estimated by Monte Carlo simulation and experimentation. Results and Discussion: The EB depth dose distribution for the eggshells indicated that acceleration voltages between 80 and 200 kV were optimal for eggshell sterilization. It was also found that acceleration voltages between 80 and 150 kV were suitable for reducing the internal dose to ≤ 0.10 Gy. Conclusion: The optimum irradiative conditions for sterilizing only eggshells with an EB were between 80 and 150 kV.

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

Effect of skin dose by materials located in treatment field (방사선 치료 시 조사야 내에 위치할 수 있는 이물질이 체표선량에 미치는 영향)

  • Hong, Chae-Seon;Kim, Kyung-Tae;Ju, Sang-Gyu;Kim, Jong-Sik;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.59-64
    • /
    • 2002
  • Purpose : In radiotherapy, various materials are used to located in treatment field unintentionally. It increases the dose delivered to the skin by interactions of the X-ray within the materials and occurs unwanted skin reaction.(due to the dose build-up effect) This aim of the this study is to measure the increase in skin dose when 13 materials are located in treatment field. Methods : Photon beam measurements were made using an plane-parallel chamber (Markus, PTW-Freiburg) in a polystyrene phantom. skin dose were measured using various overlaying 13 materials. a fixed geometry of a $10{\times}10cm$ field, a SSD=100cm and photon energy 4MV on Varian CLINAC 600C accelerator were used for all measurements. Results : There is an increase in skin dose for all materials($16.4{\sim}160.1\%$). As a percentage of maximum dose, the lowest skin dose were measured for the underwear with silk($43.2\%$) and the highest were measured for the 100m1 fluid-bag($96.6\%$) Conclusion : There is a significant increase in skin dose with 13 materials in the treatment field. a significant increase in skin dose can occur which could produce unwanted skin reaction. considerations for placement of 13 materials to be outside the treatment field whenever possible should be used to keep skin dose to a minimum level.

  • PDF