• Title/Summary/Keyword: k-band

Search Result 10,566, Processing Time 0.034 seconds

Purification of Band 3 from the Human Erythrocyte Membrane and its Incorporation into Liposome (사람 적혈구막 Band 3의 정제 및 Liposome으로의 도입)

  • Kim, Jae-Ryong;Kim, Jung-Hye;Lee, Ki-Yung
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • Band 3, the predominent 95,000 dalton anion transport protein, is the major intrinsic glycoprotein of the human erythrocyte membrane. This anion carrier exists as a dimer and binds the cytoskeletons such as spectrin, ankyrin and actin. And the liposomes are vesicular structures which form spontaneouly upon hydration of phospholipids. These artificial lipid vesicles have been investigated as model of the biological membranes and as a mean of improving the delivery of nucleic acids, drugs, proteins and biological substances to specific target tissues and cells. In this study, we were purified Band 3 from the human erythrocyte membrane(ghost) was prepared by hemolysis of intact human erythrocyte with weak alkali-hypotonic solution. Band 6 was removed from ghost by extracting with solution of an ionic strength of 0.15. Band 3 and Band 4 were solubilized selectively by extracting Band 6-depleted ghosts with Triton X-100 under nondenaturing conditions. Band 3 was then purified from Triton X-100 extract treated with p-chloromercuribenzoate by sucrose density gradient ultracentrifugation. This purified Band 3 was incorporated into liposomes prepared by reverse-phase evaporation. Phosphatidyl L-serine and cholesterol(1 : 1 molar ratio) were dissolved in chloroform and then chloroform was removed by rotatory evaporation under reduced pressure. Band 3 solution without Triton X-100 was introduced into a mixture of lipids and diethylether. Diethylether was subsequently removed by evaporation. This purified Band 3 and its incorporation into liposomes were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis.

  • PDF

Simulation of Subnet Management for InfiniBand (채널 기반 인피니밴드의 서브넷 관리를 위한 시뮬레이션)

  • Kim, Young-Hwan;Youn, Hee-Yong;Park, Chang-Won;Lee, Hyoung-Su;Go, Jae-Jin;Park, Sang-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11a
    • /
    • pp.535-538
    • /
    • 2002
  • InfiniBand is a switched-fabric architecture for next generation I/O systems and data centers. The InfiniBand Architecture (IBA) promises to replace bus-based architectures, such as PCI, with a switched-based fabric whose benefits include higher performance, higher RAS (reliability, availability, scalability), and the ability to create modular networks of servers and shared I/O devices. The switched-fabric InfiniBand consists of InfiniBand subnets with channel adapters, switches, and routers. In order to fully grasp the operational characteristics of InfiniBand architecture (IBA) and use them in ongoing design specification, simulation of subnet management of IBA is inevitable. In this paper, thus, we implement an IBA simulator and test some practical sample networks using it. The simulator shows the flow of operation by which the correctness and effectiveness of the system can be verified.

  • PDF

Estimation of Chlorophyll-a Concentrations in the Nakdong River Using High-Resolution Satellite Image (고해상도 위성영상을 이용한 낙동강 유역의 클로로필-a 농도 추정)

  • Choe, Eun-Young;Lee, Jae-Woon;Lee, Jae-Kwan
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.613-623
    • /
    • 2011
  • This study assessed the feasibility to apply Two-band and Three-band reflectance models for chlorophyll-a estimation in turbid productive waters whose scale is smaller and narrower than ocean using a high spatial resolution image. Those band ratio models were successfully applied to analyzing chlorophyll-a concentrations of ocean or coastal water using Moderate Imaging Spectroradiometer(MODIS), Sea-viewing Wide Field-fo-view Sensor(SeaWiFS), Medium Resolution Imaging Spectrometer(MERIS), etc. Two-band and Three-band models based on band ratio such as Red and NIR band were generally used for the Chl-a in turbid waters. Two-band modes using Red and NIR bands of RapidEye image showed no significant results with $R^2$ 0.38. To enhance a band ratio between absorption and reflection peak, We used red-edge band(710 nm) of RapidEye image for Twoband and Three-band models. Red-RE Two-band and Red-RE-NIR Three-band reflectance model (with cubic equation) for the RapidEye image provided significance performances with $R^2$ 0.66 and 0.73, respectively. Their performance showed the 'Approximate Prediction' with RPD, 1.39 and 1.29 and RMSE, 24.8, 22.4, respectively. Another three-band model with quadratic equation showed similar performances to Red-RE two-band model. The findings in this study demonstrated that Two-band and Three-band reflectance models using a red-edge band can approximately estimate chlorophyll-a concentrations in a turbid river water using high-resolution satellite image. In the distribution map of estimated Chl-a concentrations, three-band model with cubic equation showed lower values than twoband model. In the further works, quantification and correction of spectral interferences caused by suspended sediments and colored dissolved organic matters will improve the accuracy of chlorophyll-a estimation in turbid waters.

Component proteins in cystic fluid of Taenia sodium metacestodes collected surgically from neurocysticercosis patients (인체 유구낭미충증 환자에서 수거한 낭미충 낭액의 성분 단백질의 양상)

  • Yoon Kong;Shin-Yong Kang;Seung-Yull Cho
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 1990
  • Surgically collected cystic fluid of Taenia solium metacestodes from patients of intracranial cystic lesion were compared in their protein composition with those from naturally infected pigs in Cheju Do, Korea and Ecuador. In non-denaturing discontinuous-polyacryla aide gel electrophoresis (disc-PAGE) , no discernible differences were recognized in banding patterns between the cystic fluids from Cheju Do and Ecuador, and between the cystic quids from pigs and human lesions except wider bands that corresponded to human albumin and T-globulin (in 4 of 9 patients). In reducing SDS-PAGE, bands in the cystic Ruid from Ecuador showed the same banding pattern with that from Cheju Do but two bands of 21 and 17 kDa were stained darker. Cystic quids (rom patients revealed the same protein compositions of the major protein bands of 94, 64, 15, 10 and 7 kDa as in the cystic fluid of pig origin, but human albumin (66 kDa), heavy and light chains of gamma globulin (55 and 22.5 kDa) were contaminated in 4 of 9 cystic fluids. Human CSF proteins seem to have been contaminated during cystic ftuid collection. In any cystic quid from patients, the majcr Protein component was 150 kDa which was subdivided into 15, 10 and 7 kDa in reducing SDS-PAGE.

  • PDF

Design of TX/RX broadband L-type circular polarization Antenna using LTCC at K/Kaband (LTCC 공정을 이용한 K/Ka 대역에서의 송수신 겸용 L 형태 원형편파 안테나)

  • Oh, Min-Seok;Cheon, Young-Min;Kim, Sung-Nam;Choi, Jae-Ick;Pyo, Cheol-Sig;Lee, Jong-Moon;Cheon, Chang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2052-2054
    • /
    • 2004
  • The TX/RX broadband L-type circular polarization antenna using LTCC at K/Ka band has been presented. This antenna has been analyzed in compensation for LTCC with relative permittivity 5.2 and could have been integrated with RF component. As the measured 10dB impedance circular polarization bandwidth of the proposed antenna is 7%(20.8GHz${\sim}$22.2GHz) at the K band and 2.3%(30.9GHz to 31.6GHz) at the Ka band. Also the gain of the antenna is -0.7${\sim}$3.05dBi at the K band and -2.8${\sim}$1dBi at the Ka band. The purpose of the research is to design an efficient antenna structure for satellite communication at K/Ka band. the antenna should be used for both TX and RX frequency bands. The antenna will be mounted on LTCC(Low Temperature Co-fired Ceramic) so that it can be integrated with other RF circuits. This research is important because of the following reasons. 1) The frequency ranges of satellite communication tends to move up to higher frequency such as Ka band or milimeter wave band. 2) Design of antenna for smaller size, lighter weight and less loss is preferred by most RF engineers. 3) Antennas on LTCC enables to integrate the antenna with other RF circuits, and thus, one can reduce the size and loss of the RF system.

  • PDF

A Study of High Power Microwave Output by K-band Waveguide (K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구)

  • Kim, Won-Sop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.

A Development of Missile System Test Equipment for Ku-Band Radar Altimeter (Ku대역 전파고도계 체계점검장비 개발)

  • Kim, Taehoon;Jeong, Jinseob
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.808-815
    • /
    • 2015
  • For performance improving of C-band radar altimeter used in a missile system, Ku-band radar altimeter is developed. To utilize the time delay devices which are used in testing C-band radar altimeter, we proposed C-band and Ku-band frequency conversion method and implemented it as a part of missile system test equipment. In this paper we present design contents, development results and test application results of radar altimeter test equipments.

Theoretical analysis of transient wave propagation in the band gap of phononic system

  • Lin, Yi-Hsien;Ma, Chien-Ching
    • Interaction and multiscale mechanics
    • /
    • v.6 no.1
    • /
    • pp.15-29
    • /
    • 2013
  • Phononic system composed of periodical elastic structures exhibit band gap phenomenon, and all elastic wave cannot propagate within the band gap. In this article, we consider one-dimensional binary materials which are periodically arranged as a 20-layered medium instead of infinite layered system for phononic system. The layered medium with finite dimension is subjected to a uniformly distributed sinusoidal loading at the upper surface, and the bottom surface is assumed to be traction free. The transient wave propagation in the 20-layered medium is analyzed by Laplace transform technique. The analytical solutions are presented in the transform domain and the numerical Laplace inversion (Durbin's formula) is performed to obtain the transient response in time domain. The numerical results show that when a sinusoidal loading with a specific frequency within band gap is applied, stress response will be significantly decayed if the receiver is away from the source. However, when a sinusoidal force with frequency is out of band gap, the attenuation of the stress response is not obvious as that in the band gap.

Application of Taguchi Methodology for Optimization of Parameters of CVD Influencing Formation of a Desired Optical Band Gap of Carbon Film

  • Mishra, D.K.;Bejoy, N.;Sharon, Maheshwar.
    • Carbon letters
    • /
    • v.6 no.2
    • /
    • pp.96-100
    • /
    • 2005
  • Taguchi methodology has been applied to get an idea about the parameters related to the chemical vapour deposition technique, which influences the formation of semiconducting carbon thin film of a desired band gap. L9 orthogonal array was used for this purpose. The analysis based on Taguchi methodology suggests that amongst the parameters selected, the temperature of pyrolysis significantly controls the magnitude of band gap (46%). Sintering time has a small influence (30%) on the band gap formation and other factors have almost no influence on the band gap formation. Moreover this analysis suggests that lower temperature of pyrolysis (${\leq}$ $750^{\circ}C$) and lower time of sintering (${\leq}$ 1 h) should be preferred to get carbon thin film with the desired band gap of 1.2eV.

  • PDF

Effects of Side Walking Training with Elastic-Band on Gait and Balance of Stroke Patients (탄성밴드를 이용한 측방 보행 훈련이 뇌졸중 환자의 보행 및 균형에 미치는 영향)

  • Hong, Sung-Il;Bang, Dae-Hyuk;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.372-378
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the effect of side walking training with an elastic-band on gait and balance ability of stroke patients. Methods: Twenty three patients with stroke participated in the study. Participants were randomly assigned to the side walking with elastic-band group (n=7), the side walking without elastic-band group (n=8), and the walking on the treadmill group (n=8);. 10 m walking test (10MWT), Dynamic Gait Index (DGI), Berg Balance Scale (BBS), and modified Functional Reach Test (mFRT) were performed for evaluatione of pre- and post-intervention in gait and balance ability of participants. Results: Significantly differences in 10 MWT, DGI, BBS, and mFRT were observed between pre- and post-intervention in three groups (p<0.05). Improvement of pre- and post-intervention of mFRT showed significant difference (p<0.05). The highest rate of change was observed in the side walking with elastic-band group and rate of change showed in the order of the side walking without elastic-band group, walking on the treadmill group. Conclusion: This study suggests that side walking training with an elastic-band may help to improve gait and balance ability of stroke patients.