• Title/Summary/Keyword: journal of Korean medicine

Search Result 102,920, Processing Time 0.139 seconds

Effects on the pathogenicity and the immunogenicity of Eimeria tenella to the chickens treated with dexamethasone and testosterone propionate and on the relation with antibody titers for Newcastle disease virus (덱사메타손과 테스토스테론 호르몬으로 처리된 닭에서 Eimeria tenella의 병원성 및 면역원성과 뉴캣슬병 바이러스에 대한 항체가의 비교)

  • Youn, Hee-jeong;Noh, Jae-wuk;Oh, Hwa-gyun
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.2
    • /
    • pp.337-345
    • /
    • 1995
  • To evaluate the pathogenicity and immunogenicity of Eimeria tenella to the chicken treated with dexamethasone(DEX) and testosterone propionate (TES), we administered 0.1ml/chicken of dexamethasone and 40mg/chicken of testosterone propionate at 1-, 2-, and 7-days old, respectively. We also immunized with ND oil-emulsion vaccine at 2 weeks old. After that, we immunized and challenged with 100 and $1{\times}10^5$ oocysts/chicken of E tenella at 2 and 4 weeks old, respectively. And then we investigated the HI titers for ND virus, survival rate, body weight gain, lesion score and the weight of the bursa of Fabricius and thymus. The titers for ND virus in the groups treated with TES were higher than those in the groups treated with DEX and CON during 3 to 6 weeks. After challenge, the survival rate of testosterone propionate treated-challenged(TES-CHA) and TES-immunized and challenged(TES-V&C) groups were 61.5 and 83.3% and those of the other groups were all 100%. At 1 week after challenge, the lesion scores of TES-CHA group(4.0) was the highest of all experimental groups. Those of DEX and controlchallenged( CON-CHA) groups were 2.8, and those of all V&C groups were 2.4. During 1 and 2 weeks after immunization, the body weight gains of TES groups were severe low(61.6-82.2g and 189.6-260.4g). During 1 and 2 weeks after challenge, the body weight gains of all CHA groups were lower than those of not challenged groups. But, those of all V AC groups were not different from those of not immunized groups. At 4- and 6-weeks old, the weight of the bursa of Fabricius and thymus in the chicken of all TES groups were lower than those of all control (CON) and DEX groups. Therefore, testosterone propionate acted as immunosuppressive drug. Also, it was thought that the chicken affected a little humoral immunity to E tenella.

  • PDF

Optimum Radiotherapy Schedule for Uterine Cervical Cancer based-on the Detailed Information of Dose Fractionation and Radiotherapy Technique (처방선량 및 치료기법별 치료성적 분석 결과에 기반한 자궁경부암 환자의 최적 방사선치료 스케줄)

  • Cho, Jae-Ho;Kim, Hyun-Chang;Suh, Chang-Ok;Lee, Chang-Geol;Keum, Ki-Chang;Cho, Nam-Hoon;Lee, Ik-Jae;Shim, Su-Jung;Suh, Yang-Kwon;Seong, Jinsil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.143-156
    • /
    • 2005
  • Background: The best dose-fractionation regimen of the definitive radiotherapy for cervix cancer remains to be clearly determined. It seems to be partially attributed to the complexity of the affecting factors and the lack of detailed information on external and intra-cavitary fractionation. To find optimal practice guidelines, our experiences of the combination of external beam radiotherapy (EBRT) and high-dose-rate intracavitary brachytherapy (HDR-ICBT) were reviewed with detailed information of the various treatment parameters obtained from a large cohort of women treated homogeneously at a single institute. Materials and Methods: The subjects were 743 cervical cancer patients (Stage IB 198, IIA 77, IIB 364, IIIA 7, IIIB 89 and IVA 8) treated by radiotherapy alone, between 1990 and 1996. A total external beam radiotherapy (EBRT) dose of $23.4\~59.4$ Gy (Median 45.0) was delivered to the whole pelvis. High-dose-rate intracavitary brachytherapy (HDR-IBT) was also peformed using various fractionation schemes. A Midline block (MLB) was initiated after the delivery of $14.4\~43.2$ Gy (Median 36.0) of EBRT in 495 patients, while In the other 248 patients EBRT could not be used due to slow tumor regression or the huge initial bulk of tumor. The point A, actual bladder & rectal doses were individually assessed in all patients. The biologically effective dose (BED) to the tumor ($\alpha/\beta$=10) and late-responding tissues ($\alpha/\beta$=3) for both EBRT and HDR-ICBT were calculated. The total BED values to point A, the actual bladder and rectal reference points were the summation of the EBRT and HDR-ICBT. In addition to all the details on dose-fractionation, the other factors (i.e. the overall treatment time, physicians preference) that can affect the schedule of the definitive radiotherapy were also thoroughly analyzed. The association between MD-BED $Gy_3$ and the risk of complication was assessed using serial multiple logistic regression models. The associations between R-BED $Gy_3$ and rectal complications and between V-BED $Gy_3$ and bladder complications were assessed using multiple logistic regression models after adjustment for age, stage, tumor size and treatment duration. Serial Coxs proportional hazard regression models were used to estimate the relative risks of recurrence due to MD-BED $Gy_{10}$, and the treatment duration. Results: The overall complication rate for RTOG Grades $1\~4$ toxicities was $33.1\%$. The 5-year actuarial pelvic control rate for ail 743 patients was $83\%$. The midline cumulative BED dose, which is the sum of external midline BED and HDR-ICBT point A BED, ranged from 62.0 to 121.9 $Gy_{10}$ (median 93.0) for tumors and from 93.6 to 187.3 $Gy_3$ (median 137.6) for late responding tissues. The median cumulative values of actual rectal (R-BED $Gy_3$) and bladder Point BED (V-BED $Gy_3$) were 118.7 $Gy_3$ (range $48.8\~265.2$) and 126.1 $Gy_3$ (range: $54.9\~267.5$), respectively. MD-BED $Gy_3$ showed a good correlation with rectal (p=0.003), but not with bladder complications (p=0.095). R-BED $Gy_3$ had a very strong association (p=<0.0001), and was more predictive of rectal complications than A-BED $Gy_3$. B-BED $Gy_3$ also showed significance in the prediction of bladder complications in a trend test (p=0.0298). No statistically significant dose-response relationship for pelvic control was observed. The Sandwich and Continuous techniques, which differ according to when the ICR was inserted during the EBRT and due to the physicians preference, showed no differences in the local control and complication rates; there were also no differences in the 3 vs. 5 Gy fraction size of HDR-ICBT. Conclusion: The main reasons optimal dose-fractionation guidelines are not easily established is due to the absence of a dose-response relationship for tumor control as a result of the high-dose gradient of HDR-ICBT, individual differences In tumor responses to radiation therapy and the complexity of affecting factors. Therefore, in our opinion, there is a necessity for individualized tailored therapy, along with general guidelines, in the definitive radiation treatment for cervix cancer. This study also demonstrated the strong predictive value of actual rectal and bladder reference dosing therefore, vaginal gauze packing might be very Important. To maintain the BED dose to less than the threshold resulting in complication, early midline shielding, the HDR-ICBT total dose and fractional dose reduction should be considered.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Purification of antigenic proteins of Paragonimus westermani and their applicability to experimental cat paragonimiasis (폐(肺)디스토마(Paragonimus westermani) 감염(感染) 고양이 혈청(血淸)에 대(對)한 ELISA 항체가(抗體價)의 의의(意義))

  • Choi, Won-Young;Yoo, Jae-Eul;Nam, Ho-Woo;Choi, Hyung-Rak
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.177-186
    • /
    • 1986
  • This study was designed to evaluate the partially purified antigens which were fractionated from crude extract of Paragonimus westermani and to monitor the enzyme-linked immunosorbent assay (ELISA) in experimental cat paragonimiasis during the course of infection as well as before and after chemotherapy. Crude extract of 6-month-old adult P. westermani was fractionated to 5 antigens by successive applications of ammonium sulfate precipitation, ion exchange chromatography and gel filtration. And the cats, 10 in each group, were infected with 60, 30, 15, and 5 metacercariae, then the half of each group was treated with praziquantel 2 times in one day of 100mg per kilogram of weight on 150 days after the infection. Sera were collected every 10 days. ELISA was performed with the concentration of $2{\mu}g/ml$ antigen, 100 times diluted sera and 1,000 times diluted alkaline phosphatase conjugated anti-cat IgG. The results were as follows: 1. Absorbance by ELISA with proteins precipitated by differential concentration of ammonium sulfate was the highest at $51{\sim}65%$ precipitate (PA2), followed by $0{\sim}50%$ precipitate (PAl), $66{\sim}80%$ precipitate (PA3), and $81{\sim}90%$ precipitate (PA4). Unprecipitated protein over 90% ammonium sulfate (PA5) showed the lowest antigenicity. 2. Fractionation of PA1, PA2, and PA3 through the DEAE-cellulose column did not differentiate the antigenic proteins. 3. By passing through the Sephadex G-200 column, PA1 and PA2 were fractionated to high molecular weight proteins and those of low molecular weight which showed high absorbance by ELISA (PA1-I, II and PA2-I, II). But PA3 was shown to have a fraction of high molecular weight proteins (PA3-I) which showed high antigenicity. 4. SDS-polyacrylamide gel electrophoresis of PA1-I, P A1-II, PA2-I, PA2-II, PA3-I, and crude extract was performed. Fraction PA1-I was composed of proteins which had the molecular weight of 270 kilodaltons(KD) to 196 KD; of them 220KD protein was major band. Fraction PA2-I was composed of $255{\sim}225\;KD$, and PA3-I, $255{\sim}240\;KD$, respectively. Fraction PA1-II and fraction PA2-II consisted of 30 KD proteins. 5. Absorbance by ELISA began to increase within $10{\sim}20$ days after the infection and reached the highest on $140{\sim}180$ days, then made plateau thereafter. 6. Absorbance by ELISA decreased after praziquantel treatment. In 60 metacercariae infection group, the absorbance had been decreasing, but remained within the positive range during observation period, while those of 30, 15, and 5 metacercariae infection groups turned to negative range. 7. Fraction PA1-II showed the highest antigenicity in ELISA, then fraction PA2-I, fraction PA1-I, fraction PA2-II, fraction PA3-I and crude extract followed. In early phase of infection, the absorbance of fraction PA1-II showed more rapid increase than those of the other fractions and it came to positive range at $20{\sim}30$ days after infection.

  • PDF

Concurrent Chemoradiation Therapy in Stage III Non-small Cell Lung Cancer (III 기 비소세포성 폐암에서 Cisplatin-방사선동시병합요법의 효과)

  • Kim In Ah;Choi Ihl Bhong;Kang Ki Mun;Jang Jie Young;Song Jung Sub;Lee Sun Hee;Kuak Mun Sub;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1997
  • Purpose : This study was tried to evaluate the Potential benefits of concurrent chemoradiation therapy (low dose daily cisplatin combined with split course radiation therapy) compared with conventional radiation therapy alone in stage III non-small cell lung cancer. The end points of analyses were response rate. overall survival, survival without locoregional failure, survival without distant metastasis, prognostic factors affecting survival and treatment related toxicities. Materials and Methods : Between April 1992 and March 1994, 32 patients who had stage III non-small cell lung cancer were treated with concurrent chemoradiation therapy. Radiation therapy for 2 weeks (300 cGy given 10 times up to 3000 cGy) followed by a 3 weeks rest period and then radiation therapy for 2 more weeks (250 cGy given 10 times up to 2500 cGy) was combined with $6mg/m^2$ of cisplatin. Follow-up period ranged from 13 months to 48 months with median of 24 months. Historical control group consisted of 32 patients who had stage III non-small cell lung cancer were received conventionally fractionated (daily 170-200 cGy) radiation therapy alone. Total radiation dose ranged from 5580 cGy to 7000 cGy with median of 5940 cGy. Follow-up Period ranged from 36 months to 105 months with median of 62 months. Result : Complete reponse rate was higher in chemoradiation therapy (CRT) group than radiation therapy (RT) group (18.8% vs. 6.3%, CRT group showed lower in-field failure rate compared with RT group(25% vs. 47%. The overall survival rate had no significant differences in between CRT group and RT group (17.5% vs. 9.4% at 2 years). The survival without locoregional failure (16.5% vs. 5.3% at 2 years) and survival without distant metastasis (17% vs. 4.6% at 2 years) also had no significant differences. In subgroup analyses for Patients with good performance status (Karnofsky performance scale 80), CRT group showed significantly higher overall survival rate compared with RT group (62.5% vs. 15.6% at 2 years). The prognostic factors affecting survival rate were performance status and pathologic subtype (squamous cell cancer vs. nonsquamous cell cancer) in CRT group. In RT alone group, performance status and stage (IIIa vs IIIb) were identified as a Prognostic factors. RTOG/EORTC grade 2-3 nausea and vomiting(22% vs 6% and bone marrow toxicities (25% vs. 15.6% were significantly higher in CRT group compared with RT alone group. The incidence of RTOG/EORTC grade 3-4 pulmonary toxicity had no significant differences in between CRT group and RT group (16% vs. 6%. The incidence of WHO grade 3-4 pulmonary fibrosis also had no significant differences in both group (38% vs. 25%. In analyses for relationship of field size and Pulmonary toxicity, the Patients who treated with field size beyond 200cm2 had significantly higher rates of pulmonary toxicities. Conclusion : The CRT group showed significantly higher local control rate than RT group. There were no significant differences of survival rate in between two groups. The subgroup of patients who had good performance status showed higher overall survival rate in CRT group than RT group. In spite of higher incidence of acute toxicities with concurrent chemoradiation therapy, the survival gain in subgroup of patients with good performance status were encouraging. CRT group showed higher rate of early death within 1 year, higher 2 year survival rate compared with RT group Therefore, to evaluate the accurate effect on survival of concurrent chemoradiation therapy, systematic follow-up for long term survivors are needed.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Radiation Therapy and Chemotherapy after Breast Conserving Surgery for Invasive Breast Cancer: An Intermediate Result (침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용치료의 성적 및 위험인자 분석)

  • Lee, Seok-Ho;Choi, Jin-Ho;Lee, Young-Don;Park, Heoung-Kyu;Kim, Hyun-Young;Park, Se-Hoon;Lee, Kyu-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.16-25
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Breast conserving surgery (BCS) followed by chemotherapy (CTx.) and radiation therapy (RT) is widely performed for the treatment of early breast cancer. This retrospective study was undertaken to evaluate our interim results in terms of failure patterns, survival and relative risk factors. $\underline{Materials\;and\;Methods}$: From January 1999 through December 2003, 129 patients diagnosed with invasive breast cancer and treated with BCS followed by RT were subject to retrospective review. The median age of the patients was 45 years (age distribution, $27{\sim}76$ years). The proportions of patients according to their tumor, nodes, and metastases (TNM) stage were 65 (50.4%) in stage I, 41 (31.7%) in stage IIa, 13 (10.1%) in stage IIb, 9 (7.0%) in stage III, and 1 patient (0.8%) in stage IIIc. For 32 patients (24.8%), axillary node metastasis was found after dissection. BCS consisted of quadrantectomy in 115 patients (89.1%) and lumpectomy in 14 patients (10.6%). Axillary node dissection at axillary level I and II was performed for 120 patients (93%). For 7 patients (5.4%), only sentinel node dissection was performed with BCS. For 2 patients (1.6%) axillary dissection of any type was not performed. Postoperative RT was given with 6 MV X-rays. A tumor dose of 50.4 Gy was delivered to the entire breast area using a tangential field with a wedge compensator. An aditional dose of $9{\sim}16\;Gy$ was given to the primary tumor bed areas with electron beams. In 30 patients (23.3%), RT was delivered to the supraclavicular node. Most patients had adjuvant CTx. with $4{\sim}6$ cycles of CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens. The median follow-up period was 50 months (range: $17{\sim}93$ months). $\underline{Results}$: The actuarial 5 year survival rate (5Y-OSR) was 96.9%, and the 5 year disease free survival rate (5Y-DFSR) was 93.7%. Local recurrences were noted in 2 patients (true: 2, regional node: 1) as the first sign of recurrence at a mean time of 29.3 months after surgery. Five patients developed distant metastases as the first sign of recurrence at $6{\sim}33$ months (mean 21 months). Sites of distant metastatic sites were bone in 3 patients, liver in 1 patient and systemic lesions in 1 patient. Among the patients with distant metastatic sites, two patients died at 17 and 25 months during the follow-up period. According to stage, the 5Y-OSR was 95.5%, 100%, 84.6%, and 100% for stage I, IIa, IIb, and III respectively. The 5Y-DFSR was 96.8%, 92.7%, 76.9%, and 100% for stage I, IIa, IIb, and III respectively. Stage was the only risk factor for local recurrence based on univariate analysis. Ten stage III patients included in this analysis had a primary tumor size of less than 3 cm and had more than 4 axillary lymph node metastases. The 10 stage III patients received not only breast RT but also received posterior axillary boost RT to the supraclavicular node. During the median 53.3 months follow-up period, no any local or distant failure was found. Complications were asymptomatic radiation pneumonitis in 10 patients, symptomatic pneumonitis in 1 patient and lymphedema in 8 patients. $\underline{Conclusion}$: Although our follow up period is short, we had excellent local control and survival results and reaffirmed that BCS followed by RT and CTx. appears to be an adequate treatment method. These results also provide evidence that distant failure occurs earlier and more frequent as compared with local failure. Further studies and a longer follow-up period are needed to assess the effectiveness of BCS followed by RT for the patients with less than a 3 cm primary tumor and more than 4 axillary node metastases.

A Survey of Nutritional Status on Pre-School Children in Korea (학영기전아동(學齡期前兒童)의 영양실태조사(營養實態調査))

  • Ju, Jin-Soon;Oh, Seoung-Ho
    • Journal of Nutrition and Health
    • /
    • v.9 no.2
    • /
    • pp.68-86
    • /
    • 1976
  • The primary purpose of this study is to evaluate the correct nutritional status on pre-school children in Korea. Furthermore, it made an attempt to find and define nutrional problems, and assist in establishment on their nutritional improvement plan. For this, food intake and health condition (physical, clinical, biochemical and parasitological) survey on 109 Pre-school children in both sexes, randomly selected from Yang-Gu area in Gang-Won province and Rea-ju area in Kyong-gy Province, were conducted by means of three-day records, during the two periods of Spring and Fall season in 1975. The results obtained are summerized as follows: 1. The food intake; Average food intake of the subjects per day were $508{\sim}647g$ ($83{\sim}91%$ in vegetable foods and $5.5{\sim}11.7%$ in animal foods) in Yang-gu area, and $587{\sim}698g$ ($88{\sim}89%$ in vegetable foods and $6.3{\sim}7.6%$ in animal foods) in Rea-ju area. 2. The intake of energy and nutrients; a) Calory intake. Average energy intake of subjects per day in Yang-gu area$(1120{\sim}1415kcal)$ were all lower than the Korean Recommended Dietary Allowances (RDA) in either Spring and Fall survey, whereas the subjects in Rea-ju area were lower intake $(1213{\sim}1418kcal)$ than the RDA in the Spring but higher intake$(1516{\sim}1755kcal)$ than the RDA in the Fall, and the average intake were similar level with that of RDA. b) Protein intake. Average protein intake of the subjects per day in Yang-gu area $(33{\sim}43g)$ girl subjects in Rea-ju area $(35{\sim}39g)$ were lower than the RDA in either Spring and Fall survey, whereas the boy subjects in Rea-ju area$(36{\sim}38g)$ were lower in Spring and higher $(49{\sim}57g)$ in the Fall than that of the RDA, but the average $(43{\sim}47g)$ were similar level with the RDA. The protein intake from animal sources in all subjects were much lower $(5.5{\sim}11.7\;of\;total\;protein)$ than the RDA. c) Fat intake. Average fat intake were very lower in all subjects of both area $(14{\sim}24g\;in\;Yang-gu,\;10{\sim}12g\;in\;Rea-ju)$ than that of RDA which is recommended $12{\sim}14%$ of total energy to be supplied from fat. d) Calcium intake. Average calcium intake were very low in all subjects of both area $(264{\sim}355mg\;in\;Yang-gu\;and\;283{\sim}429mg\;in\;Rea-ju)$, especially, these in Spring were about a half level of the RDA, and it was much increased in the Fall due to increased intake of milk, but it was still not enough than the RDA. e) Vitamin A intake. Average intake of V.A ($703{\sim}1465\;IU$ in Ynag-gu and $750{\sim}1521\;IU$ in Rea-ju) were also lower than the RDA, moreover their V-A sources were mainly vegetable, so that the V-A supply might be critical one for the subjected. f) Riboflavin intake. Average riboflavin intake on all subjects in both area except boys in Rea-ju area in Fall, were very lower than the RDA. 3. The physical status; a) Average weight and height of boys aged 4 and 5 in Yang-gu area and girls of aged 5 in Rea-ju area were lower than those of Korean Standard of 1967 report, but those by age of girls in Yang-gu area and boys in Rea-ju area were a little heigher than the Korean Standard. It is, hower, present Korean standard of physical status might be somehow heigher than the 1967, since the socio-economical situation has been much improved during past a decade. So that, if one considered on this sense, the physical status of the subjects on this survey might be somehow lower than those of present Korean standard. b) Average upper arm circumference in both area were no difference each other, and their mean values of age 4, 5 and 6 in boy and girl were 15.6, 16.5, 16.4 and 15.5, 16.5, 16.4cm respectively. c) Average chest girth of boys were similar to those of Korean standard whereas the girls were smaller than the Korea standard. The average head circumference also showed similar tendency with the chest girth. 4. The clinical findings; The most popular clinical signs were angular stomatitis and dental caries, and boys had more heigher incidence then the girls. 5. The biochemical findings; a) Hemoglobin and anemia Average Hb value of boys and girls were 11.4 and 10.9g per 100 ml of blood respectively. The incidence of anemia (Hb value below 11 g/100 ml, by WHO) was increased by age, and girls had more heigher incidence than the boy (34% : 48%). The incidence of anemia in age of 4,5, and 6 in boys and girls were 28%, 41% 34%, and 33%, 50%, 49% respectively. The degree of the anemia was not severe, and the anemia of there subjects may be caused mainly low intake of better quality protein and low iron intake as well. b) Hematocrit. Average Ht value of whole subject were $39.9{\sim}41.6%$. c) Blood plasma protein. Average blood plasma protein contents of whole subjects were $6.6{\sim}7.4gm$ per 100 ml. The incidence of deficient range (<6.0g%, by ICNND) was only one girl of age 4 in yang Gu area. 6. Parasitological findgs; The most popular parasitism were asicris lumbicoides and trichocephalus trichiura, and about 2/3 of the whole subjects were suffering one or more of these parasitism.

  • PDF

A Study on the Visions of Zechariah in the Old Testament from a Perspective of Analytical Psychology (구약성서 '스가랴'서의 환상에 대한 분석심리학적 연구)

  • Sang Ick Han
    • Sim-seong Yeon-gu
    • /
    • v.29 no.1
    • /
    • pp.1-45
    • /
    • 2014
  • Mystic experience such as seeing an vision could be explained as experiencing elusive and mysterious unique existence in religious way. In depth psychology, which is based on unconsciousness like analytical psychology, this could be explained as a something that gives a meaning of life and purpose through discovering health and healing. The importance of primodial experience in depth psychology is that it can possibly discover the base of present acts. In Christian theology, symbolic mystery and truth of religious experience that appear in Christian tradition have interest on human situation. These two fields' approach methods are different, but both show common interest on unique experience which can be said properly as raw experience. Various visions appear in many parts of the Bible. Among many visions, the book of Zechariah, one of the 12 Prophets, describes rich and diverse 8 visions through chapter 1 to chapter 8. However, due to the Genre of revelation, it lacks historicity, and because of vagueness and symbolic meanings, its visions are hard to understand and interpret. Theologically, visions of Zechariah show communality of Israelites by reconstructing kingdom of Judah and church in a way of historical circumstances. Though, these visions could deliver the meaning of an ethnical aspect as reporting continuous conversation between the God and humans. Furthermore, it could mean a personal aspect of the Prophet Zechariah as reaching for a opportunity of new change. Moreover, those who read these visions could try to interpret the meanings of various images which represent meeting mysterious existences. Therefore, the Author would concentrate on the fact that 8 visions in the book of Zechariah, which has not been received much attention to neither Christians nor non-believers, develop in chiastic structure (stylistic contrast), so that tries to interpret the first, second, seventh, and the eighth visions in analytic psychology way. In visions of Zechariah, excepting the 4th vision which probably was inserted later, rest of 7 visions each shows the stage of the hours of darkness. 1st to 3rd visions represent evening, 5th vision represents deep in the night, and 6th to 8th visions represent dawn to morning. Moreover, since structure of visions arranged in chiastic way, horse appears in 1st and 8th vision, measuring rope and measure tools are used as main motif in 2nd and 7th vision. However, same motifs could have different symbolic meanings and roles as visions are formed in different situations and conditions. In the first vision, angels who ride horses look around the world and report it is calm and peaceful. Concerning the political situation back in the day, the world being calm and peaceful in the beginning of evening means that it is not ready to change to a whole new world. Psychologically, if there is no readiness to adopt new world, it means being hopeless. It is sending you a message to get out of those kinds of situation. Moreover, appearance of four angels who rode red, brown, and white horses to a myrtus tree in the valley means that it is time for individuation and it is right and good timing for changing. In second vision, you will be able to see that Israelites had long years being caught in the shadows by foreign country, and long years succumbed by the strength of four horns, which shows the progress of renewing strength and being oneness with oneself from overwhelmed situation by paternity. In seventh vision, meaning of two women bringing the godness of the sky, who were locked up in a rice basket, back to the temple in Babylon is going towards in a level of Self-actualization by separating one's ego captured excessively by matherhood and putting back to a place where it was before. In eighth vision, chariots pulled by horses are scattered far and wide, and horses which went to north had rest in the land of North. After horses and chariots are seen between two mountains of bronze with the image of Self and anima/animus. These images can be explained as the changing progress are almost completed and the God and human, in other words Self and ego are being united and is now time for rest. All of 8 visions contains the conversation between angel and Zechariah who willing to know the meaning of visions. Zechariah asks the angel actively about the meaning of visions because of his wish for Israelites to return home and rebuild church. Conversation among the God, Zechariah, who asks questions until he knows everything, an Angel, who gives answer to given questions, is conversation between ego and anima/animus. Eventually, it is a conversation between Self and ego.

A Study on Serum Lipid Levels of Elderly People in Wando Area -Based on Dietary Behaviors- (완도지역 중·장년층의 혈중지질 수준에 관한 연구 -식행동을 중심으로-)

  • Kim, Eun-Ju;Cha, Bok-Kyeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.9
    • /
    • pp.1148-1160
    • /
    • 2007
  • This study was performed to document the association between eating behaviors and major risk factors for cardiovascular diseases. Those who stated that they ate a daily breakfast for male and female were 88.6% and 96.0%, $1{\sim}2$ times a week were 9.1% and 2.0%, $3{\sim}4$ times a week were 2.3% and 2.0%, respectively. Those who stated that they were overeating of $0{\sim}1$ time a week for man and female were 80.7% and 89.9%, overeating of $2{\sim}3$ times a week were 19.3% and 10.1%, respectively. Those who said that they were regular of meal time for man and female were 38.6%, and 37.4%, sometimes irregular of meal time were 14.8% and 19.2%, irregular of meal time were 46.6% and 43.4%, respectively. Those who said that they were light of eating volume for man and female were 20.5% and 25.3%, moderate of eating volume were 69.3% and 61.6%, heavy of eating volume were 10.2% and 13.1%, respectively. Those who said that they were very fast of eating speed for man and female were 15.9% and 8.1%, fast of eating speed were 51.1% and 34.3%, moderate of eating speed were 4.5% and 20.2%, slow of eating speed were 17.0% and 14.1%, and very slow of eating speed were 11.4% and 23.2%, respectively. Higher frequency of breakfast a week resulted in higher serum total cholesterol and blood sugar for the daily eating group for both genders with women having high LDL-cholesterol and HDL-cholesterol. Both group had high HDL-cholesterol and low blood sugar with less number of overeating, with men having low triglyceride and LDL-cholesterol. With regular meal, both group had low triglyceride, total-cholesterol, atherogenic index, and blood sugar with women having low LDL-cholesterol. For both groups, the triglyceride, total-cholesterol, LDL-cholesterol, atherogenic index, and blood sugar had higher figures for overeating, with men having low HDL-cholesterol and women having high HDL-cholesterol. This study revealed that less number of overeating, regular mealtime, and less volume of food intake are effective in preventing and treating for the cardiovascular diseases.