• Title/Summary/Keyword: joint-strength

Search Result 2,466, Processing Time 0.024 seconds

Reliability of Fine Pitch Solder Joint with Sn-3.5wt%Ag Lead-Free Solder (Sn-3.5wt%Ag 비납솔더를 이용한 미세피치 솔더접합부의 신뢰성에 관한 연구)

  • 하범용;이준환;신영의;정재필;한현주
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.89-96
    • /
    • 2000
  • As solder becomes small and fine, the reliability and solderability of solder joint are the critical issue in present electronic packaging industry. Besides the use of lead(Pb) containing solders for the interconnections of microelectronic subsystem assembly and packaging has enviromental problem. In this study, using Sn/Pb and Sn/Ag eutectic solder paste, in order to obtain decrease of solder joint strength with increasing aging time, initial solder joint strength and aging strength after 1000 hour aging at $100^{\circ}C$ were measured by peel test. And in order to obtain the growth of intermetallic compound(IMC) layer thickness, IMC layer thickness was measured by scanning electron microscope(SEM). As a result, solder joint strength was decreased with increasing aging time. The mean IMC layer thickness was increased linearly with the square root of aging time. The diffusion coefficient(D) of IMC layer was found to $1.29{\times}10^{-13}{\;}cm^2/s$ at using Sn/Pb solder paste, 7.56{\times}10^{-14}{\textrm}{cm}^2/s$ at using Sn/Ag solder paste.

  • PDF

A study of the gradient establishment for Rock slope considering joints characteristics. (절리 특성을 고려한 암반사면의 절취경사 기준 설정에 관한 연구)

  • 이수곤;김부성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.501-508
    • /
    • 2002
  • The percentage of a mountainous district in our country is comparatively high but the concern for rock mass has been disregarded for a long time. Especially for rock slope, the most important factors are geometric characteristics and their shear strength parameter. In this paper, parametric studies are performed using the distinct element computer program UDEC-BB for rock slopes. Parameters adopted in this paper are joint angle, spacing, persistence, aperture and shear strength parameters (JRC, JCS, basic friction angle). To estimate slope stability, shear strength reduction method is used. The most important factors affecting rock slope stability are joint angle and spacing. The relationship between average displacement calculated by UDEC-BB and safe factor by shear strength reduction method is researched.

  • PDF

A study on the strength of mechanically fastened composite joint using the linear analysis (선형해석을 이용한 복합재료 기계적 체결부의 강도평가에 관한 연구)

  • Chun, Young-Jun;Choi, Jin-Ho;Kweon, Jin-Hwe;Lee, Sang-Chan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.9
    • /
    • pp.49-56
    • /
    • 2004
  • With the wide application of fiber-reinforced composite material in aero-structures and mechanical parts, the design of composite joint have become a very important research area because they are often the weakest areas in composite structures. In this paper, the linear finite element analyses in which the pin of the composite joint was assumed to be the frictionless rigid body were performed and predict the strength of the mechanically fastened composite joint using the failure area index method. By the failure area index method, the strength of the mechanically fastened composite joint which has the specimen of different shape, hole size and stacking sequence could be predicted within 12.2%.

Comparison of Ankle Joint Exercise and Thigh Exercise on the Isometric Strength of the Lower Limb and Balance Ability (다리 등척성 근력 및 균형 능력에 대한 발목관절 운동과 넓적다리 운동의 비교)

  • Lee, Woo-Jung;Lee, Sun-Ah;Kim, Ah-Ram;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.4
    • /
    • pp.153-162
    • /
    • 2019
  • PURPOSE: This study compared ankle joint exercise and thigh exercise on the isometric strength of the lower limb and balance ability. METHODS: Twenty-seven subjects were divided into ankle joint exercise (AEG, n=9), tight exercise (TEG, n=9), and control group (CON, n=9). AEG and TEG performed ankle joint and tight exercises three times a week for four weeks. The following were measured before and four weeks after each exercise: isometric strength at knee flexion and extension of the lower limb; isometric strength at ankle plantar flexion and dorsiflexion of the lower limb; static balance of trace length and C90 area; and the dynamic forward, backward, leftward, and rightward balance for each region. RESULTS: The results showed that the isometric strength of plantar flexion (p<.05) was increased significantly in AEG compared to those in TEG and CON. The dynamic leftward (p<.05) and rightward balance (p<.05) were increased significantly in both AEG and TEG compared to that in CON. On the other hand, the static balance of the trace length and C90 area, isometric strength of ankle dorsiflexion, knee flexion and extension of the lower limb, and dynamic forward and backward balance did not show significant differences between the groups. CONCLUSION: Ankle joint exercise improves the isometric strength of plantar flexion compared to tight exercise.

Different Biomechanical Characteristics in Proprioception, Muscle Strength, and Time to Peak Torque at Velocity of 300°/sec of the Ankle Joint in People With or Without Functional Ankle Instability (각속도 300°/sec에서 기능적 발목불안 유무에 따른 고유수용성감각, 발목 근력, 그리고 최고 회전력까지 걸리는 시간의 생체역학적 특성 차이)

  • Park, Eun-Young;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • The purpose of this study was to examine the differentiation of proprioception, invertor and evertor muscle strength, and time to peak torque at a velocity of $300^{\circ}/sec$ of the ankle joint in people with or without functional ankle instability (FAI). Nineteen subjects with a history of ankle sprain participated. All subjects were divided into FAI group ($n_1=9$, Cumberland ankle instability tool (CAIT)${\leq}24$) and a control group ($n_2=10$) based on their CAIT scores. Isokinetic dynamometer was used to measure the sense of active joint position of the ankle at mid-range and end-range of an inversion motion and invertor as well as the evertor muscle strength and time to peak torque at $300^{\circ}/s$. The FAI group showed a statistically reduction in invertor and evertor muscle strength and time to peak torque when compared to the control group (p<.05). Muscle strength and time to peak torque of the invertor and evertor, as well as the sense of active joint position at end-range were also lower in the FAI group than in the control (p<.05). Correlations between CAIT score and position sense at end-range (r=-.577) and invertor muscle strength (r=.554) were statistically significant (p<.05). Individuals with FAI showed reduction in invertor and evertor muscle strength and recruitment time as well as in proprioception of the ankle joint. Thus, proprioception and invertor and evertor muscle strength of the ankle joint at fast angular velocity may be investigated when examining and planning care for individuals with FAI.

Improvement of Solder Joint Strength in SAC 305 Solder Ball to ENIG Substrate Using LF Hydrogen Radical Treatment (SAC 305솔더와 ENIG 기판의 접합강도에 미치는 저주파 수소라디칼처리의 영향)

  • Lee, Ah-Reum;Jo, Seung-Jae;Park, Jai-Hyun;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.99-106
    • /
    • 2011
  • Joint strength between a solder ball and a pad on a substrate is one of the major factors which have effects on electronic device reliability. The effort to improve solder joint strength via surface cleaning, heat treatment and solder composition change have been in progress. This paper will discuss the method of solder ball joint strength improvement using LF hydrogen radical cleaning treatment and focus on the effects of surface treatment condition on the solder ball shear strength and interfacial reactions. In the joint without radical cleaning, voids were observed at the interface. However, the specimens cleaned by hydrogen-radical didn't have voids at the interface regardless of cleaning time. The shear strength between the solder ball and the pad was increased over 120%(about 800gf) when compared to that without the radical treatment (680gf) under the same reflow condition. Especially, at the specimen treated for 5minutes, ball shear strength was considerably increased over 150%(1150gf). Through the observation of fracture surface and cross-section microstructure, the increase of joint strength resulted from the change of fracture mode, that is, from the solder ball fracture to IMC/Ni(P) interfacial fracture. The other cases like radical treated specimen for 1, 3, 7, 9min. showed IMC/solder interfacial fracture rather than fracture in the solder ball.

Shear strength of match-cast-free dry joint in precast girders

  • Jiang, Haibo;Feng, Jiahui;Xiao, Jie;Chen, Mingzhu;Liang, Weibin
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.161-173
    • /
    • 2020
  • Shear keys in precast concrete segmental bridges (PCSBs) are usually match-casting which is very labour intensive. In this research, an innovative match-casting-free construction was proposed by leaving small gap between the convex and the concave castellated shear keys in the joints of PCSBs. Specimen experiment, shear strength analysis and numerical simulation were conducted, investigating the loading performance of this new type of dry joints, the gap dry joints. Compared with match-casting joint specimens, it has been found from experiment that shear capacity of gap joint specimens significantly decreased ranging from 17.75% to 42.43% due to only partially constrained and contacted in case of gap dry joints. Through numerical simulation, the effects of bottom contacting location, the heights of the gap and the shear key base were analyzed to investigate strength reduction and methods to enhance shear capacity of gap joint specimens. Numerical results proved that shear capacity of gap dry joints under full contact condition was higher than that under partial contact. In addition, left contact destroyed the integrity of shear keys, resulting in significant strength reduction. Larger shear key base remarkably increased shear capacity of the gap joint. Experimental tests indicated that AASHTO provision underestimated shear capacity of the match-casting dry joint specimens, while the numerical results for the gap dry joint showed that AASHTO provision underestimated shear capacity of full contact specimens, but overestimated that of left contact specimens.

A Study on the Fatigue Strength and Allowable Stress of INVAR(Fe-36% Ni) Steel Lap Joint Applied to Cargo Containment of LNG Carrier (LNG선용 INVAR(Fe-36%Ni)강 Lap 이음부의 피로강도와 허용응력에 관한 연구)

  • 한명수;한종만;한용섭
    • Journal of Welding and Joining
    • /
    • v.12 no.1
    • /
    • pp.102-115
    • /
    • 1994
  • This paper is to evaluate the fatigue strength of lap joints of materials applied to LNG carrier cargo containment of GAZ-TRANSPORT(GT) type, which was welded by manual and automatic TIG welding process. The thicknesses of lapped members were 1.5mm/1.5mm or 1.5mm/0.7mm in Invar to Invar joint, and 1.5mm/8.0mm in Invar to stainless steel joint, respectively. These lap joints were mainly applied to the membrance fabrication of GT-LNG carrier. Fatigue tests of Invar/Inar lap joints were conducted under the stress ratio R=0 at room temperature. The effect of mean stress and cumulative fatigue damage on the allowable stress of Invar lap joint was evaluated on the basis of test results. Fatigue test was also conducted on Inver/Stainless steel lap joints welded by automatic TIG process without filler metals. The fatigue test of the joint was carried out under the same conditions as those of Invar/invar lap joints. The fatigue strength of the joint welded without filler metal was comparable to those welded with filler metal quoted from reference. The fatigue strength of Invar/stainless steel lap joint was only dependent on the lap throat thickness, and not on the welding process. Based on test results, the applicability of TIG welding process without filler metal in Invar/stainless steel lap joint was reviewed by controlling welding variables to assure the valid throat thickness of lap joints.

  • PDF

Fracture mechanical evaluation of fatigue strength of a single spot welded lap joint under tension-shear load (인장-전단하중을 받는 일점 Spot용접재의 파괴역학적 피로강도 평가)

  • 배동호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.42-50
    • /
    • 1991
  • According as the members and inner and outer plates of the automobile body structure have been thinned their thickness and have become high strength, each part of the body structure has been put more severe stress condition. Therefore, it has been increasingly required to improve the fatigue strength of the spot welded structures. As one of the improving methods for such problem, the author had previously proposed the method of alleviating stress concentration at nugget edge of the spot weld part and improving its fatigue strength [1]. But, because fatigue strength of the spot welded lap joint is influenced by its geometrical and mechanical factors, welding condition and etc., there needs a quantitative and systematic estimation method of them. In this report, by considering nugget edge of the spot weld part of the spot welded lap joint subjected to tensile load to the ligament crack, fatigue strength of various spot welded lap joints was estimated with the stress intensity factor (S.I.F.) K which is fracture mechanical parameter. It is known that evaluation of fatigue strength of the spot welded lap joint by the stress intensity factor (S.I.F.) K is more effective than the maximum stress $(\sigma_{ymax}$) at edge of the spot weld part on the center line of width of the plate.

  • PDF

Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements (무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교)

  • Park, Bo-hyun;Choi, Su-hong;Kim, Sung-joong;Park, Su-hyung;Oh, Kang-o
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.