• Title/Summary/Keyword: joint power

Search Result 998, Processing Time 0.034 seconds

A Study of the Thermal Analysis of Horizontal Fillet Joints by Considering the Bead Shape in GMA Welding (GMA 용접에서 비드형상을 고려한 수평필릿용접부의 온도해석에 관한 연구)

  • Jo, Si-Hun;Kim, Jae-Ung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.71-78
    • /
    • 2001
  • In GMA(Gas Metal Arc)Welding, the weld size that is a locally melted area of a workpiece is one of the most important considerations in determining the strength of a welded structure. Variations in the weld power and the welding heat flux may affect the weld pool formation and ultimately the size of the weld. Therefore, an accurate prediction of the weld size requires a precise analysis of the weld thermal cycle. In this study, a model which can estimate the weld bead geometry and a method for thermal analysis, including the model, are suggested. In order to analyze the weld bead geometry, a mathematical model was developed with transformed coordinates to apply to the horizontal fillet joints. A heat flow analysis was performed with a two dimensional finite element model that was adopted for computing the base metal melting zone. The reliability of the proposed model and the thermal analysis was evaluated through experiments, and the results showed that the proposed model was very effective for predicting the weld bead shape and good correspondence in melting zone of the base metal.

  • PDF

Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable (22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석)

  • Kim, Young-Seok;Kim, Taek-Hee;Kim, Chong-Min;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

A Survey on the Co-Generation Load for Large Commercial Buildings (대형상업건물의 열병합발전 부하조사)

  • 한승호;권순우;정상원;정재혁
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • Energy consumption statistics have been surveyed for 50 large commercial buildings with high energy consumption records in Seoul City. The buildings were classified into three different groups for data analysis: hospitals, hotels, and department stores/office buildings. The analysis was focused on identifying installed boiler and refrigerator data, energy consumption rates, and energy load distribution throughout the year. Refrigerating electricity was confirmed again to affect most on the formation of the summer electricity load peak as expected. Replacing the refrigerator electricity peak in the summer with co-generation in large commercial buildings. However, overall heat load distribution in a single building is still considered not large enough for economically feasible co-generation and thus joint co-generation for multiple neighboring buildings are preferred and the Electric Power Law and LNG pricing policy should be revised favorably for co-generation in advance.

  • PDF

Influence of ground motion spatial variations and local soil conditions on the seismic responses of buried segmented pipelines

  • Bi, Kaiming;Hao, Hong
    • Structural Engineering and Mechanics
    • /
    • v.44 no.5
    • /
    • pp.663-680
    • /
    • 2012
  • Previous major earthquakes revealed that most damage of the buried segmented pipelines occurs at the joints of the pipelines. It has been proven that the differential motions between the pipe segments are one of the primary reasons that results in the damage (Zerva et al. 1986, O'Roueke and Liu 1999). This paper studies the combined influences of ground motion spatial variations and local soil conditions on the seismic responses of buried segmented pipelines. The heterogeneous soil deposits surrounding the pipelines are assumed resting on an elastic half-space (base rock). The spatially varying base rock motions are modelled by the filtered Tajimi-Kanai power spectral density function and an empirical coherency loss function. Local site amplification effect is derived based on the one-dimensional wave propagation theory by assuming the base rock motions consist of out-of-plane SH wave or combined in-plane P and SV waves propagating into the site with an assumed incident angle. The differential axial and lateral displacements between the pipeline segments are stochastically formulated in the frequency domain. The influences of ground motion spatial variations, local soil conditions, wave incident angle and stiffness of the joint are investigated in detail. Numerical results show that ground motion spatial variations and local soil conditions can significantly influence the differential displacements between the pipeline segments.

Thermo-mechanical analysis of road structures used in the on-line electric vehicle system

  • Yang, B.J.;Na, S.;Jang, J.G.;Kim, H.K.;Lee, H.K.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.3
    • /
    • pp.519-536
    • /
    • 2015
  • On-line electric vehicle (OLEV) is a new eco-friendly transportation system that collects electricity from a power cable buried beneath the road surface, allowing the system to resolve various problems associated with batteries in electric vehicles. This paper presents a finite element (FE) based thermo-mechanical analysis of precast concrete structures that are utilized in the OLEV system. An experimental study is also conducted to identify materials used for a joint filler, and the observed experimental results are applied to the FE analysis. Traffic loading and boundary conditions are modeled in accordance with the related standards and environmental characteristics of a road system. A series of structural analyses concerning various test scenarios are conducted to investigate the sensitivity of design parameters and to evaluate the structural performance of the road system.

A Study of the Myoelectronic Hand for a Hand Amputee (상지절단 장애인용 전동의수에 관한 연구)

  • Kim, Myung-Hoe;Jang, Dae-Jin
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.133-141
    • /
    • 2002
  • This purpose of this study was to design the effect of recovering of a hand amputees by Myoelectronic hand. It was designed with 2 degree of freedom in the laboratory. Myoelectronic hand had only one degree of freedom and one movement until now. Also this myoelectronic hand had multi-joint and it could move widely. Wire was used in transmission. Myoelectronic hand data was obtained by analyzing hand anatomically and measuring and that data was applied when it was designed. PID controller of Myoelectronic hand was used to it. Displacement control was applied the first link. Experiment was accomplished in Tip grasp, Power grasp and Hook grasp modes. Displacement control was good in low frequency. Velocity control was applied to each mode. The objective of the study was to develop more better multifunction myoelectronic control strategies. A myoelectronic hand with a hand amputees could do some jobs such as grasping materials, lifting weighting, holding cup and etc. As a result of this study, all subjects with hand amputees significantly improved in ADL. Further studies were needed to evaluate the effect of a myoelectronic hand with more precise laboratory equipment.

  • PDF

Median Frequency Analysis of Shoulder Muscles Using EMG Power Spectrum Analysis After Rotator Cuff Repair

  • Kang, Jeong-Il;Moon, Young-Jun
    • International Journal of Contents
    • /
    • v.10 no.3
    • /
    • pp.90-95
    • /
    • 2014
  • The purpose of this study was to analyze the changes in muscle fatigue by using electromyography (EMG) measurements of the median frequency of shoulder muscles of patients who underwent rotator cuff repair, and to provide basic data for efficient exercise methods during rehabilitation after the repair. In the study, 24 male and 8 female patients who underwent rotator cuff repair performed continuous passive shoulder joint motion for 3 weeks and the median frequency of their shoulder muscles before and after the repair were compared using measurements by EMG. The infraspinatus, supraspinatus, and serratus anterior muscles showed significant differences in the changes in the median frequency before and after the repair. Significant differences were also found in the median frequency of the three muscles both before and after the repair. Additionally, the middle deltoid muscle had a lower median frequency than the supraspinatus muscle before the repair and the infraspinatus muscle had a lower median frequency than the middle deltoid muscle after the repair. It is expected that these results will serve as important data in developing rehabilitation exercise programs for the infraspinatus, supraspinatus, and serratus anterior muscles by compensating the middle deltoid muscle with the lowest muscle fatigue after the rotator cuff repair erase.

Inter-Cell Interference Management for Next-Generation Wireless Communication Systems

  • Kwon, Ho-Joong;Ko, Soo-Min;Seo, Han-Byul;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.10 no.3
    • /
    • pp.258-267
    • /
    • 2008
  • In this paper, we examine what changes the next-generation wireless communication systems will experience in terms of the technologies, services, and networks and, based on that, we investigate how the inter-cell interference management should evolve in various aspects. We identify that the main driving forces of the future changes involve the data-centric services, new dynamic service scenarios, all-IP core access networks, new physical-layer technologies, and heavy upload traffic. We establish that in order to cope with the changes, the next-generation inter-cell interference management should evolve to 1) set the objective of providing a maximal data rate, 2) take the form of joint management of power allocation and user scheduling, 3) operate in a fully distributed manner, 4) handle the time-varying channel conditions in mobile environment, 5) deal with the changes in interference mechanism triggered by the new physical-layer technologies, and 6) increase the spectral efficiency while avoiding centralized coordination of resource allocation of the users in the uplink channel.

Countermovement of the Segments During the Tae-kwon-do Roundhouse Kicking (태권도 돌려차기 시 분절들의 반동동작)

  • Hwang, In-Seong;Lee, Sung-Cheol;Lim, Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.139-152
    • /
    • 2004
  • Two subjects, an expert and a novice, were carefully selected based upon their foot speed. Three dimensional videography was used in the assessment of roundhouse kicking of the Tae-kwon-Do. The local reference frames were imbedded at the trunk, pelvis, thigh and shank. Anatomical angular displacement at the joints were measured by projecting the upper segment's local axes to the lower segment's local reference planes. The local axes again projected to the global reference frames and absolved each segment's movement. The peaks of the anatomical angular displacement curve assessed as the countermovements and the angular movements of the segments in the global space absolved in light of the occurrence of the countermovements. The expert showed larger and more countermovements than the novice at the all segments. The counterrnovement occured more clearly at the trunk than the hip and knee joint and during the preparative movement phase. These countermovements occurrence were due to either by turning upper or lower segments and controlled by the turning direction and sequence of the two nearby segments. It was revealed that the countermovements of the trunk during the preparative movement phase was the important factor of the power kicking.

THE DEVELOPMENT OF THE NARROW GAP MULTI-PASS WELDING SYSTEM USING LASER VISION SYSTEM

  • Park, Hee-Chang;Park, Young-Jo;Song, Keun-Ho;Lee, Jae-Woong;Jung, Yung-Hwa;Luc Didier
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.706-713
    • /
    • 2002
  • In the multi-pass welding of pressure vessels or ships, the mechanical touch sensor system is generally used together with a manipulator to measure the gap and depth of the narrow gap to perform seam tracking. Unfortunately, such mechanical touch sensors may commit measuring errors caused by the eterioration of the measuring device. An automation system of narrow gap multi-pass welding using a laser vision system which can track the seam line of narrow gap and which can control welding power has been developed. The joint profile of the narrow gap, with 250mm depth and 28mm width, can be captured by laser vision camera. The image is then processed for defining tracking positions of the torch during welding. Then, the real-time correction of lateral and vertical position of the torch can be done by the laser vision system. The adaptive control of welding conditions like welding Currents and welding speeds, can also be performed by the laser vision system, which cannot be done by conventional mechanical touch systems. The developed automation system will be adopted to reduce the idle time of welders, which happens frequently in conventional long welding processes, and to improve the reliability of the weld quality as well.

  • PDF