• 제목/요약/키워드: joint panel

검색결과 198건 처리시간 0.026초

Vacuum Packaging Technology of AC-PDP using Direct-Joint Method

  • Lee, Duck-Jung;Lee, Yun-Hi;Moon, Gwon-Jin;Kim, Jun-Dong;Choi, Won-Do;Lee, Sang-Geun;Jang, Jin;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • 제2권4호
    • /
    • pp.34-38
    • /
    • 2001
  • We suggested new PDP packaging technology using the direct joint method, which does not need an exhausting hole and tube. The advantages of this method are simple process, short process time and time panel package. To packaging, we drew the seal line of glass frit by dispenser followed by forming the lump, which provide pumping-out path during the packaging process. And, we have performed a pretreatment of glass frit to reduce the out-gases. After which, both front and rear glass plates were aligned and loaded into vacuum packaging chamber. The 4-inch monochrome AC-PDP was successfully packaged and fully emitted with brightness of 1000 $cd/m^2$. Also, glass frit properties for pretreatment condition was investigated by AES and SEM analyses.

  • PDF

Seismic performance of self-sustaining precast wide beam-column connections for fast construction

  • Wei Zhang;Seonhoon Kim;Deuckhang Lee;Dichuan Zhang;Jong Kim
    • Computers and Concrete
    • /
    • 제32권3호
    • /
    • pp.339-349
    • /
    • 2023
  • Fast-built construction is a key feature for successful applications of precast concrete (PC) moment frame system in recent construction practices. To this end, by introducing some unique splicing details in precast connections, especially between PC columns including panel zones, use of temporary supports and bracings can be minimized based on their self-sustaining nature. In addition, precast wide beams are commonly adopted for better economic feasibility. In this study, three self-sustaining precast concrete (PC) wide beam-column connection specimens were fabricated and tested under reversed cyclic loadings, and their seismic performances were quantitatively evaluated in terms of strength, ductility, failure modes, energy dissipation and stiffness degradation. Test results were compared with ASCE 41-17 nonlinear modeling curves and its corresponding acceptance criteria. On this basis, an improved macro modeling method was explored for a more accurate simulation. It appeared that all the test specimens fully satisfy the acceptance criteria, but the implicit joint model recommended in ASCE 41-17 tends to underestimate the joint shear stiffness of PC wide beam-column connection. While, the explicit joint model along with concentrated plastic hinge modeling technique is able to present better accuracy in simulating the cyclic responses of PC wide beam-column connections.

철근콘크리트 보-기둥 접합부의 연성능력 (Deformability of RC Beam-Column Assembles)

  • 이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.193-196
    • /
    • 2008
  • 이 연구에서는 지진하중을 받는 철근콘크리트 보-기둥 접합부의 연성능력을 평가하였다. 철근콘크리트 보-기둥 접합부 설계는 보에 소성힌지가 발생하기 이전에 접합부가 파괴하는 경우와 보에 소성힌지가 발생한 이후에 접합부 또는 보가 파괴하는 경우로 구분하여 설계하고 있다. 지금까지의 대부분의 기존 연구는 접합부의 강도 평가에 중점을 두고 있으며, 접합부의 연성능력 평가에 대한 연구는 미흡한 실정이다. 이 연구에서는 접합부의 연성을 기둥, 보, 접합부 패널 부분으로 구분하여 각각의 부재가 보-기둥 접합부의 전체 연성에 미치는 영향을 평가하였다. 접합부 설계는 일반적으로 보에 소성힌지를 발생시키고 접합부를 포함한 기둥은 탄성 상태로 설계하므로 탄성해석에 의하여 기둥의 연성을 평가하였다. 접합부 패널은 보의 소성힌지의 변형에 의하여 영향을 받게 된다. 따라서 이 연구에서는 보의 소성힌지의 영향을 고려한 접합부 패널 연성을 평가하였다. 소성힌지가 발생한 보의 연성은 보-기둥 접합부의 연성능력에 가장 큰 영향을 미친다. 보의 연성은 보의 휨에 의한 영향, 철근의 뽑힘에 의한 영향, 소성힌지 구역의 축방향 변형률 증대에 의한 영향으로 구분하였다. 또한 접합부의 부착강도 저감 및 보의 주철근 항복 이후의 철근의 뽑힘 및 소성힌지 구역의 축방향 변형률 증대에 의한 영향을 고려하여 보의 연성능력을 평가하였다.

  • PDF

국제민간항공기구의 무인기 정책 개발 동향 (A Trend of Policy for Remotely Piloted Aircraft System Panel in International Civil Aviation Organization)

  • 안효정;원정윤
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권2호
    • /
    • pp.117-122
    • /
    • 2016
  • 세계적으로 무인기 활용이 증가하고 이와 관련한 사고 보도도 잇따르고 있는 가운데 각국 정부 당국, 관련 기관 및 산업체 등에서는 무인기 운영 관련 정책 및 규정 제 개정을 위한 노력에 박차를 가하고 있다. 또한 이와 동시에 국제민간항공기구에서 관련 연구조직(UASSG, Unmanned Aerial System Study Group)을 통해 국제 표준 마련을 위한 공동 연구를 진행해 왔다. 최근에는 국제민간항공기구에서 무인기패널체(RPASP, Remotely Piloted Aircraft System Panel)를 조직하여 무인기의 민간공역 통합 운영을 목표로 관련 부속서, 표준 및 권고 등을 제 개정하기 위한 논의를 수행하고 있다. 본 논문에서는 국제민간항공기구의 무인기 정책 연구 및 개발 동향을 조사하고, 이를 통해 국내 무인기 정책 마련을 위해 필요한 사항을 제안하였다. 이는 국제적인 무인기 정책 및 규정 개발 동향을 파악하여 관련 산업개발 방향 설정 및 국내 규정 마련에 기초자료로 활용할 수 있을 것이다.

Experimental and numerical investigation on in-plane behaviour of hollow concrete block masonry panels

  • Murthy, A. Rama Chandra;Ganapathi, S. Chitra;Iyer, Nagesh R.;Lakshmanan, N.;Bhagavan, N.G.
    • Computers and Concrete
    • /
    • 제10권1호
    • /
    • pp.1-18
    • /
    • 2012
  • This paper presents the details of studies conducted on hollow concrete block masonry (HCBM) units and wall panels. This study includes, compressive strength of unit block, ungrouted and grouted HCB prisms, flexural strength evaluation, testing of HCBM panels with and without opening. Non-linear finite element (FE) analysis of HCBM panels with and without opening has been carried out by simulating the actual test conditions. Constant vertical load is applied on the top of the wall panel and then lateral load is applied in incremental manner. The in-plane deformation is recorded under each incremental lateral load. Displacement ductility factors and response reduction factors have been evaluated based on experimental results. From the study, it is observed that fully grouted and partially reinforced HCBM panel without opening performed well compared to other types of wall panels in lateral load resistance and displacement ductility. In all the wall panels, shear cracks originated at loading point and moved towards the compression toe of the wall. The force reduction factor of a wall panel with opening is much less when compared with fully reinforced wall panel with no opening. The displacement values obtained by non-linear FE analysis are found to be in good agreement with the corresponding experimental values. The influence of mortar joint has been included in the stress-strain behaviour as a monolith with HCBM and not considered separately. The derived response reduction factors will be useful for the design of reinforced HCBM wall panels subjected to lateral forces generated due to earthquakes.

새로운 개념의 복합재 샌드위치 체결부 구조의 설계와 검증 (Design and Verification of a Novel Composite Sandwich Joint Structure)

  • 곽병수;주현우;김홍일;동승진;권진회
    • Composites Research
    • /
    • 제30권6호
    • /
    • pp.384-392
    • /
    • 2017
  • 인장과 압축하중 모두를 효과적으로 지지할 수 있는 새로운 샌드위치 체결부 구조의 설계를 위해, 체결부 형상이 다른 3가지 샌드위치 판넬에 대한 인장 및 압축 시험을 수행하였다. 샌드위치 판넬의 코어는 주로 알루미늄 플렉스 허니콤이지만, 타 구조물과의 체결을 위해 두께가 얇아지면서 단순 적층판으로 변하는 램프 영역에서는 PMI 폼 코어를 사용하였고, 면재에는 탄소섬유 복합재를 사용하였다. 형상 1에서는 복합재 플랜지와 샌드위치 구조가 일체형으로 연결된다. 형상 2와 3에서는 별도로 제작된 알루미늄 플랜지가 복합재 적층판에 하이록핀과 접착제로 체결된다. 시험 결과 형상 1, 2, 3의 평균 압축파손하중은 각각 295 kN, 226 kN, 291 kN으로 나타났고, 평균 인장파손하중은 각각 47.3(층간분리), 83.7 kN(볼트파손), 291 kN(치구손상)으로 나타났다. 압축 파손하중만을 고려할 경우 플랜지와 샌드위치 판넬을 복합재 일체형으로 제작한 형상 1과 3이 우수한 특성을 보였다. 그러나 형상 1의 경우 인장하중을 받을 때 낮은 하중에서 플랜지 모서리 부분에서 층간분리가 발생하였다. 따라서 인장과 압축하중을 동시에 효과적으로 지지할 수 있는 구조는 모서리에서 층간분리의 위험이 없게 별도의 알루미늄 플랜지를 사용하여 볼트로 체결한 형상 3임을 확인하였다.

부스바 접촉 상태 및 온도 감지 시스템 설계 및 구현 (A Design and Implementation of Busbar Joint and Temperature Measurement System)

  • 이영동;정성학
    • 한국정보통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.379-385
    • /
    • 2017
  • 일반적으로 배전반, 분전반, 전동기제어반(Motor Control Center; MCC)은 집단거주지역, 빌딩, 학교, 공장, 항만, 공항, 상하수 처리장, 변전소, 중공업 플랜트 등의 광범위한 전력 수용가에 설치되어 특고압의 전력을 해당 설비들에 요구되는 전압으로 변환하여 공급하는데 사용된다. 이와 같은 배전반, 분전반, MCC에 포함되는 전기설비의 사고는 부스바 접촉부의 열화에 의한 사고, 부스바의 접점 및 연결 부위에서의 접촉 불량에 의한 사고, 부스바 접촉부의 과열현상에 의한 사고로 구분된다. 본 논문에서는 부스바 접촉부의 볼트 및 너트의 풀림상태, 접촉부 열화 측정이 가능하며, 정밀 가변저항을 이용하여 저항값의 변화에 따라 볼트 체결상태 감지 및 비접촉식 적외선 센서를 사용하여 부스바 접촉부 온도 감지 시스템을 설계하고 구현하였다. 부스바 접촉부 체결상태 감지를 위한 가변저항을 이용한 실험을 수행한 결과 볼트와 너트를 완전히 체결시키면 가변저항 값은 감소하였으며, 최대 오차범위는 0.1mm의 결과를 보였다. 또한, 부스바 접촉 저항값 변화에 따라 접촉부 온도가 $27.3^{\circ}C$에서 $69.3^{\circ}C$로 상승하는 결과를 확인하였다.

대형 콘크리트 판넬구조의 수직접합부 전단강도에 관한 연구 (Shear Strength of the Vertical Joints in Precast Concrete Large Panel Structures)

  • 서수연;이원호;이리형
    • 콘크리트학회지
    • /
    • 제6권1호
    • /
    • pp.111-119
    • /
    • 1994
  • 대형 콘크리트 패널구조 시스템의 수직접합부 저항요소는 접합부 충전 그라우트의 부착과 전단키에 의한 맞물림작용, 철근을 장부작용으로서, 이들 요인의 상관관계에 의해 그 내력이 결정된다. 따라서 수직접합부에 관한 연구는 대부분이 이들 요인에 관한 연구로 국한된다고 할 수 있다. 수직접합부의 전단강도에 관한 연구는 국외의 많은 연구자들에 의해 실시되었으며 그 결과 여러 실험식이 제시되어 있는 상황이다. 국내에서도 수직접합부에 관한 일련의 실험연구가 진행되어 설계식이 제시되었으나, 이들 설계식은 국부적인 실험결과만을 대상으로 제시되었기 때문에 보다 많은 실험결과를 근거로한 설계식이 요망된다. 본 연구에서는 국내에서 실험된 총 94개의 수직접합부 실험결과를 분석하고 수정된 Mohr-Coulomb의 항복선이론을 적용하여 적합한 설계식을 제시하고자 하였다. 제안된 설계식은 전단키의 효과와 횡보강근의 효과를 고려한 식으로서 모르터 또는 콘크리트를 그라우트로 사용하며 횡보강근으로 루프철근을 사용한 수직접합부에 적용된다. 실험결과의 희구분석과 항복선 이론을 이용한 수식의 전개로부터 제안된 설계식의 정확성과 경제성을 평가 한 결과, 본 제안식이 실험결과를 안전측으로 평가할 뿐만아니라 기존식에 비하여 경제적인 설계가 가증한 것으로 나타났다.

루프이음 반두께 프리캐스트 바닥판을 갖는 콘크리트 바닥판의 균열폭 제어 (Crack Width Control on Concrete Slab using Half-Depth Precast Panels with Loop Joints)

  • 김동욱;심창수
    • 대한토목학회논문집
    • /
    • 제35권1호
    • /
    • pp.19-29
    • /
    • 2015
  • 반두께 프리캐스트 콘크리트 바닥판의 적용이 증가함에 따라, 프리캐스트 구조물 간의 연결에 대한 연구가 증가하고 있다. 또한, 프리캐스트 패널을 갖는 합성바닥판에서 패널간에는 횡방향 이음부의 연속적인 거동이 요구된다. 이 논문에서는 루프이음 방식을 적용하여 교축방향 패널과 패널사이의 이음부에 구조적 연속성과 성능을 평가하였다. 실험결과로부터 바닥판의 연속성 확보를 위한 루프철근 이음부의 휨강도 및 균열제어의 연속성을 확인하였다. 실험결과 루프이음 철근 간격을 좁게 한 경우의 휨강도가 1.52배 증진되는 효과를 보였다. 또한, 루프이음부에 횡방향 철근은 균열제어에 매우 효율적임을 확인하였다.

External retrofit of beam-column joints in old fashioned RC structures

  • Adibi, Mahdi;Marefat, Mohammad S.;Arani, Kamyar Karbasi;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.237-250
    • /
    • 2017
  • There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.