• Title/Summary/Keyword: joint measurement

Search Result 797, Processing Time 0.025 seconds

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

A Proposal for the Conceptual Interoperability Measurement Model Based on DOTMLPF-p (전투발전요소 중심의 상호운용성 평가모델 제안)

  • Lim, Byung-Youn;Lee, Tae-Gong
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.2
    • /
    • pp.169-180
    • /
    • 2013
  • The effectiveness of joint operations depends on Jointness based on interoperable elements of participating forces. Many specialists have actively done research studies on interoperability measurement models with the goal of straightforward way of measuring and then have improved the interoperability of elements based on DOTMLPF-p (Doctrine, Organization, Training, Materiel, Leadership & Education, Personnel, Facilities, Policy) in the forces. After the survey of 16 interoperability measurement models, we have concluded that most of them applied only a small portion of DOTMLPF-p elements explicitly or all portions of DOTMLPF-p elements implicitly. In this study, we propose a conceptual interoperability measurement model for applying all DOTMLPF-p elements explicitly. And it can evaluate not only the level of interoperability among forces but also level of jointness for joint operations.

Effects of Angle and Direction of Maximal Isometric Contraction of Non-Hemiparetic Knee on Electromyographic Activity of Hemiparetic Quadriceps Femoris in Patients With Stroke (뇌졸중 환자의 비마비측 슬관절 등척성 수축시 각도와 운동 방향이 마비측 대퇴사두근 활성도에 미치는 영향)

  • Ki, Kyong-Il;Kim, Suhn-Yeop;Oh, Duck-Won;Choi, Jong-Duk;Kim, Kyung-Hwan
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • To develop effective training methods for strengthening a weakened quadriceps femoris muscle in hemiplegic patients, we examined the effects of maximal isometric contraction of the nonparalyzed knee joint on the electromyographic activities of the paralytic muscle. An electromyogram (EMG) was used to record the electromyographic activities of the paralytic quadriceps femoris muscle in 27 hemiplegic patients. The maximal isometric contraction was measured for each subject to normalize the electromyographic activities. The maximal isometric extension and flexion exercises were randomly conducted when the knee joint angles of the nonparalyzed knees were $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$. The patients were encouraged to maintain maximal isometric contractions in both knee joints during each measurement, and three measurements were taken. A one-minute rest interval was given between each measurement to minimize the effects of muscle fatigue. An average from the three values was taken as being the root mean square of the EMG and was recorded as being the maximal isometric contraction. The electromyographic activity obtained for each measurement was expressed as a percentage of the reference voluntary contraction, which was determined using the values obtained during the maximal isometric contraction. The results of this study are summarized as follows: First, when the knee joint angle of the nonparalyzed knee was $0^{\circ}$, the electromyographic activities of the paralytic medial aspect of rectus femoris were related to measurement by a maximal isometric flexion exercise than by an extension exercise (p<.05). Second, when the knee joint angle of the nonparalyzed knee was $90^{\circ}$, the electromyographic activities of the paralytic lateral aspect of rectus femoris were related to measurement by a maximal isometric flexion exercise than by an extension exercise (p<.05). The results show that myoelectrical activities of paralytic quardriceps were not related to measurement angles and exercise directions of the nonparalized knee joint. Studies on various indirect intervention to improve muscular strength of patients with nervous system disorders of the weakened muscle should be constantly conducted.

Difference of Proprioceptive Sense at Elbow Joint According to Measurement Methods (팔굽관절에서 측정방법에 따른 고유수용성감각 차이)

  • Lee, Jung-Ah;Kim, Duk-Hwa;Shin, Hwa-Kyung;Choi, Kyu-Hwan;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.63-70
    • /
    • 2003
  • The purpose of this study was to compare the difference of joint position sense between measurements. Fourteen healthy male subjects were recruited for this study. The elbow joint position senses were measured using angle reproduction test. The elbow joint position sense was assessed with three experimental conditions: ipsilateral reproduction test in open-chain condition, contralateral reproduction test in open-chain condition, ipsilateral reproduction test with weight in open-chain condition and ipsilateral reproduction test in closed-chain condition. The angular difference between stimulus position and the reproduced position (angular error) was calculated in all testing conditions to examine the accuracy of the joint position sense. One way ANOVA was used to compare the error angles in all experimental conditions. The error angles between measurements were significantly different in elbow joint. The error angles was smallest in ipsilateral reproduction test with weight in open-chain condition and was greatest in the contralateral reproduction test in open-chain condition. Findings of this study indicate that testing methods, types of task, existence of resistance should be considered in clinical assessment for the joint position sense.

  • PDF

Joint distribution of wind speed and direction in the context of field measurement

  • Wang, Hao;Tao, Tianyou;Wu, Teng;Mao, Jianxiao;Li, Aiqun
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.701-718
    • /
    • 2015
  • The joint distribution of wind speed and wind direction at a bridge site is vital to the estimation of the basic wind speed, and hence to the wind-induced vibration analysis of long-span bridges. Instead of the conventional way relying on the weather stations, this study proposed an alternate approach to obtain the original records of wind speed and the corresponding directions based on field measurement supported by the Structural Health Monitoring System (SHMS). Specifically, SHMS of Sutong Cable-stayed Bridge (SCB) is utilized to study the basic wind speed with directional information. Four anemometers are installed in the SHMS of SCB: upstream and downstream of the main deck center, top of the north and south tower respectively. Using the recorded wind data from SHMS, the joint distribution of wind speed and direction is investigated based on statistical methods, and then the basic wind speeds in 10-year and 100-year recurrence intervals at these four key positions are calculated. Analytical results verify the reliability of the recorded wind data from SHMS, and indicate that the joint probability model for the extreme wind speed at SCB site fits well with the Weibull model. It is shown that the calculated basic wind speed is reduced by considering the influence of wind direction. Compared to the design basic wind speed in the Specification of China, basic wind speed considering the influence of direction or not is much smaller, indicating a high safety coefficient in the design of SCB. The results obtained in this study can provide not only references for further wind-resistance research of SCB, but also improve the understanding of the safety coefficient for wind-resistance design of other engineering structures in the similar area.

Development of a Vision System for the Measurement of the Pendulum Test (진자검사 계측을 위한 영상 시스템의 개발)

  • Kim, Chul-Seung;Moon, Ki-Wook;Lee, Soo-Young;Eom, Gwang-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.817-819
    • /
    • 2007
  • The purpose of this work is to develop a measurement system of the pendulum test with minimal restriction of experimental environment and little influence of noise. In this work, we developed a vision system without any line between markers and a camera. The system performance is little influenced by the experimental environment, if light are sufficient to recognize markers. For the validation of the system, we compared knee joint angle trajectories measured by the developed system and by the magnetic sensor system during the nominal pendulum test and the maximum speed voluntary knee joint rotation. The joint angle trajectories of the developed system during both tests matched well with those of the magnetic system. Therefore, we suggest the vision system as an alternative to the previous systems with limited practicality for the pendulum test.

A Study on the Measurement of Force Improvement Effectiveness of Korean Joint Command & Control System (한국군합동지휘통제체계의 전투력 상승효과 측정에 관한 연구)

  • Jung, Whan-Sik;Lee, Jae-Young
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2008.10a
    • /
    • pp.348-352
    • /
    • 2008
  • KJCCS(Korean Joint Command & Control System) is a system that integrate each military tactics C4ISR into JCS(Joint Chiefs of Staff) level. It is established in major CP(Commanding Post) and provides all battlefield situation in real time by sharing that between connection troops. The objective of this study is to suggest a way for the measurement of force improvement effectiveness of KJCCS. C2 model is applied to measure force improvement effectiveness of KJCCS. This study will be also present a requirement logic for C4ISR system acquisition later.

  • PDF

Effect of Thermal Cycle on Strength of Ceramic and Metal Joint (세라믹/금속접합재의 강도에 미치는 열사이클 영향)

  • 박영철;오세욱;김광영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1664-1673
    • /
    • 1994
  • As a fundamental study on effects of thermal-cycles on residual stress of ceramics/metal joints, residual stresses in $Si_3N_4$/SUS304 joint specimens were measured before and single thermal-cycle by X-ray diffraction method and finite element method(FEM). The residual stress was found to increase after single thermal-cycle, which was agreeable with the results of residual stress measurement by X-ray diffraction method and residual stress analysis by finite element method. After the residual stress measurement, 4-point bending tests were performed. The relationship between the bending strength, the thermal-cycle temperature and hold time was examined. The bending strength was found to decrease with the increase of residual stress in linear relation.

A study on the fitness measurement of artificial femur through medical image processing (의료영상처리를 이용한 인공고관절 정합도 측정 방법에 관한 연구)

  • 김용호;김중규
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1071-1074
    • /
    • 1999
  • In this paper, we studied a computer based three dimensional implantation system of artificial hip joint. The system can be utilized for doctors to select a suitable artificial femur which is best-fit for the patient and to find out the optimal implanting position as well. We proposed a new numerical index to measure the fitness between the artificial hip joint and the patient's femur. The proposed fitness index accounts for the variance of the distance between the outer contours of artificial hip joint and the femur in addition to the conventional area comparison. A few simulation are run to show results of fitness measurement and compared to the conventional method.

  • PDF

Effects of Viewing Angle on the Estimation of Joint Angles in the 2-dimensional Plane (2차원 면에서의 자세 관측시 시야각이 관절각 추정에 미치는 영향)

  • Lee, In-Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.51-62
    • /
    • 2006
  • In assessing risks related to working posture, pictures of postures are taken from various directions, which can be a source of observation error. Joint postures of the neck, lower back, knee, shoulder, and elbow were taken from 7 different viewing angles and 19 observers estimated joint angles by observing the pictures in 2-dimensional display. The joint angles were also measured using an optoelectronic motion measurement system. The estimation error increased as the viewing angle varies from the right side of the human body, but the patterns differ according to which joint angles were being observed. Guidelines to increase the validity of observation of joint angles were presented based on the results. In general, it is recommended to maintain the viewing angle within 20 degrees from the right side of the human body, while different ranges of viewing angle are recommended for each joint angle.