• 제목/요약/키워드: joint measurement

검색결과 797건 처리시간 0.024초

Bi-2223 초전도선재의 상전도- 및 초전도-접합부 특성평가 (Characterization of resistive-and supercodncuting-joint of Bi-2223 superconductor tape)

  • 김정호;지봉기;박형상;임준형;오승진;주진호;황보훈;나완수
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.247-253
    • /
    • 2000
  • We evaluated the electric properties of Bi-2223 jointed tapes processed by both resistive-and superconducting-joint methods. For resistive-joint. filler materials of wood metal Pb/Sn. In and silver paste were used whereas for superconductive-joint lap joint method was used. In the resistive joint tape. critical transport property(CCR) n-value and contact resistance were observed to be in the range of 10-85% 1-8,9. and 0.71x10$\^$-6/-0.13x10$\^$-6/Ω, respectively. depending on their filler materials. Specifically it is believed that the electrical properties of resistive joint tape are significantly related to the resistivity of filler materials. On the other hand the CCR of superconductin joint type was varied 55 to 85% with uniaxial pressure probably due to the irregular microstructure in the transition region.

  • PDF

Analysis of tool grip tasks using a glove-based hand posture measurement system

  • Yun, Myung-Hwan;Freivalds, Andris;Lee, Myun-W.
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1994년도 춘계공동학술대회논문집; 창원대학교; 08월 09일 Apr. 1994
    • /
    • pp.596-605
    • /
    • 1994
  • An efficient measurement and evaluation system for hand tool tasks will provide a practical solution to the problem of designing and evaluating manual tool tasks in the workplace. Few studies on the biomechanical analysis of hand postures and tool handling tasks exist because of the lack of appropriate measurement techniques for hand force. A measurement system for the finger forces and joint angles for analysis of manual tool handling tasks was developed in this study. The measurement system consists of a force sensing glove made from twelve Force Sensitive Resistors and an angle-measuring glove (Cyberglove$\^$TM/, Virtual technologies) with eighteen joint angle sensors. A biomechanical model of the hand using the data from the measurement system was also developed. Systems of computerized procedures were implemented integrating the hand posture measurement system, biomechanical analysis system, and the task analysis system for manual tool handling tasks. The measurement system was useful in providing the hand force data needed for an existing task analysis system used in CTD risk evaluation. It is expected that the hand posture measurement developed in this study will provide an, efficient and cost-effective solution to task analysis of manual tool handling tasks. These tasks are becoming increasingly important areas of occupational health and safety of the country.

Discontinuity Orientation Measurement (DOM) 시추장비 및 코어절리 해석모델 개발 (Development of Discontinuity Orientation Measurement (DOM) Drilling System and Core Joint Analysis Model)

  • 조태진;유병옥;원경식
    • 터널과지하공간
    • /
    • 제13권1호
    • /
    • pp.33-43
    • /
    • 2003
  • 암반구조물 설계를 위한 지반조사에서 지하 암반에 분포된 불연속면들의 방향성 파악은 시추공 내부에 대한 영상촬영 기법에 전적으로 의존되어 왔다. 그러나, 공내 영상촬영은 고가의 장비가 요구되며 시추작업 완료 후 측정작업이 추가로 소요되어 극히 제한적으로 수행되고 있다. 본 연구에서는 시추조사시 간편하게 불연속면의 방향을 측정하여 신뢰성 있는 지반정보 자료를 제공할 수 있는 Discontinuity Orientation Measurement (DOM) 시추장비 및 불연속면 분포해석 모델 RoSA-DOM을 개발하였다. DOM 시추 장비에서 기 설정된 방향성을 지시하는 기준선이 표시된 시추 코어가 회수되면 코어 상의 절리 단면에서 측정된 3개 지점의 자표를 이용하여 절리면의 경사방향 및 경사각을 산정한다. 또한 코어 축이 절리면을 관통하는 지점의 좌표를 산정하여 절리 위치를 설정한다. 절리군 형성은 clustering algerian을 활용하여 분석한다. 코어 축을 조사선으로 설정하여 전체 절리 간격 및 군 간격을 해석한다. 전체 시추구간 및 특정 구역에서의 RQD를 산정하여 암반의 공학적 활용도 고찰을 위한 기본 자료를 도출한다.

스마트폰을 이용한 무릎관절 고유수용성 감각 측정의 타당도와 신뢰도 검증 (Validity and Reliability of the Knee Joint Proprioceptive Sensory Measurements using a Smartphone)

  • 김명철;김남재;이민수;문소라
    • 대한물리의학회지
    • /
    • 제10권4호
    • /
    • pp.15-23
    • /
    • 2015
  • PURPOSE: We aims to promote the development of proprioception measurement using smartphones, goniometers, and laser pointers as compared to the conventional use of electrogoniometer measurement. METHODS: Measurements using an electrogoniometer were previously proved to be reliabile and valid. Among E-university students, 20 who had no fracture, operation history, or inflammatory arthritis were examined. These subjects had not performed regular exercise in the past 3 months. Proprioception measurements were performed using four different measurement tools, three times per day, for test-retest analysis. RESULTS: No notable test-retest differences were noted for any of the measurement methods (P>0.05). With regard to the test-retest reliability for each measurement method, we observed that the readings from both the electrogoniometer and smartphone have high reliability (ICC>0.80), whereas the readings from the laser pointer have moderate reliability (ICC>0.60). When assessing the concurrent validity between electrogoniometers with individual measurements, we did not observe any notable difference between the smartphone and electrogoniometer (P>0.05) and these tools in fact showed high correlation (r>0.60, P<0.05) and a moderate reliability (ICC>0.60). Moreover, there was no notable difference in between electrogoniometers and laser pointers (P<0.05). CONCLUSION: CONCLUSION: The findings of this suggested that proprioception can be measured by using smart-phones, and proved that this method has sufficient credibility. Moreover, we noted that the concurrent validity with smartphones was high in comparison with the conventional electrogoniometer, which also indicates the validity and credibility. Based on these findings, we conclude that the measurement of proprioception by using a smartphone can be widely adopted.

Nb_{3}$Sn 초전도 CICC의 sub-cable to sub-cable 접합 및 접합저항 측정 (Measurement of electrical resistance at the Nb_{3}$Sn CICC joint fabricated by sub-cable to sub-cable joining)

  • 이호진;홍계원;김기백;권선칠;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.89-92
    • /
    • 1999
  • A small scale joint sample of Nb3Sn CICC was fabricated by sub-cable to sub-cable joining. This joint was produced by parallel insertion of one end of each sub-cable into the sub-cable space of the other side of cable, which can decrease the equivalent electrical resistance at the joint is expected to have average properties, dc resistance and ac losses, in view of the shapes of ITER type joint and strand to strand joint. The 3.8nOhm of dc resistance was measured in the range of 10-200A transport current. The normalized resistivity of the joint was about 6.7 $\mu}$Ohm-$^mm{2}$. Considering the normalized resistivity, the full scale joint prepared by sub-cable to sub-cable joining may have similar joint dc resistance with other conventional full scale joints with a shorter joining length.

  • PDF

동력식 조립공구의 측정불확도 산출방법 개발 (Calibration Methods for Measurement Uncertainty of Power Assembly Tools)

  • 오세헌;강기영;홍민성
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.496-501
    • /
    • 2015
  • In this study, calibration procedure of power assembly tools is suggested and methods are developed for calculating measurement uncertainty. Fist of all, the calibration of joint simulator bench (JSB) was carried out for maintaining traceability and the uncertainty components of JSB were analyzed. The influences of tool speed, tolerance, temperature and length of the adapter were examined by the torque measurement values through experiments. From this research, credibility for calibration results could be enhanced. This experimental results, being used as an effective tool for calibration of power assembly tools, will provide and improve the accuracy of the use of the power assembly tools.

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF

소형무인경전철 레일이음매의 적정 간격 산정 연구 (A Study on Optimum Spacing of Rail Joint for Personal Rapid Transit(PRT) Track System)

  • 최정열;김필수;정지승
    • 문화기술의 융합
    • /
    • 제4권3호
    • /
    • pp.213-220
    • /
    • 2018
  • 본 연구에서는 레일이음매를 배제할 수 없는 각관형 레일을 사용하는 PRT궤도구조를 대상으로 레일이음매 설치위치 및 간격을 최적화함으로써 레일이음매부의 충격 및 승차감 저하 현상을 최소화 하고자 수치해석 및 현장측정을 통해 열차주행 시 PRT 차량의 실 열차속도를 고려한 궤도 구조의 일반부 및 레일이음매부의 동적거동을 파악하여 레일이음매의 적정간격을 산정하였다.

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

간호사의 수분 섭취배설량 측정에 대한 인식도와 수행도 (Nurses' Perception and Practice of Fluid Intake and Output Measurement)

  • 강남이;안숙희
    • 근관절건강학회지
    • /
    • 제23권2호
    • /
    • pp.84-94
    • /
    • 2016
  • Purpose: This research aimed to identify levels of nurses' perception and practice of fluid intake and output (I & O) measurement and to explore the relationship between perception and practice of it. Methods: Using a cross-sectional survey design, 195 nurses who practiced fluid I & O measurement were recruited from a general hospital. Nurses who agreed to participate in this study completed a structured study questionnaire to assess their levels of perception and practice of fluid I & O measurement. Results: A level of perception of I & O measurement was high (3.46 points out of 5), and scores for 3 subdomains of I & O (importance, accuracy, and efficacy) were evenly high. The level of practice of I & O was fairly high (3.76 points out of 5). Perception and practice of I & O were highly correlated (r=.73, p<.001). Conclusion: Nurses seem to have higher levels of perception and do practice fluid I & O measurement correctly. In order to have reliable and valid I & O measures, nurses need to have continuous education on I & O measurement based on clinical guideline to utilize it as an invaluable clinical instrument.