• 제목/요약/키워드: joint connection

검색결과 569건 처리시간 0.021초

Detection and location of bolt group looseness using ultrasonic guided wave

  • Zhang, Yue;Li, Dongsheng;Zheng, Xutao
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.293-301
    • /
    • 2019
  • Bolted joints are commonly used in civil infrastructure and mechanical assembly structures. Monitoring and identifying the connection status of bolts is the frontier problem of structural research. The existing research is mainly on the looseness of a single bolt. This article presents a study of assessing the loosening/tightening health state and identifying the loose bolt by using ultrasonic guided wave in a bolt group joint. A bolt-tightening index was proposed for evaluating the looseness of a bolt connection based on correlation coefficient. The tightening/loosening state of the bolt was simulated by changing the bolt torque. More than 180 different measurement tests for total of six bolts were conducted. The results showed that with the bolt torque increases, value of the proposed bolt-tightening index increases. The proposed bolt-tightening index trend was very well reproduced by an analytical expression using a function of the torque applied with an overall percentage error lower than 5%. The developed damage index based on the proposed bolt-tightening index can also be applied to locate the loosest bolt in a bolt group joint. To verify the effectiveness of the proposed method, a bolt group joint experiment with different positions of bolt looseness was performed. Experimental results show that the proposed approach is effective to detect and locate bolt looseness and has a good prospect of finding applications in real-time structural monitoring.

Cyclic behavior of steel beam-to-column connections with novel strengthened angle components

  • Kang, Lan;Zhang, Cheng
    • Steel and Composite Structures
    • /
    • 제42권6호
    • /
    • pp.791-804
    • /
    • 2022
  • As a type of semi-rigid connection, the top and seat angle connections are popular in current structures owing to their good cyclic performance and simple erection. However, their stiffness and load bearing capacity are relatively insufficient. This study proposes two strengthening methods to further increase the stiffness and strength of bolted-angle joints while maintaining satisfactory energy dissipation capacity (EDC) and ductility. Cyclic loading tests were conducted on six joint specimens with different strengthened angle components. Based on the test results, the influence of the following important factors on the cyclic behavior of steel joint specimens was investigated: the position of the rib stiffeners (edge rib stiffeners and middle rib stiffener), steel strength grade of rib stiffeners (Q345 and Q690), and additional stiffeners or not. In addition, the finite element models of these specimens were built and validated through a comparison of experimental and numerical results. The stiffness and bearing capacity of the bolted-angle joints could be improved significantly by utilizing the novel strengthened joints proposed in this study. Moreover, this can be achieved with almost no increase in the amount of steel required, and the EDC of this joint could also satisfy the requirements of seismic codes from various countries.

Mechanical performance of a new I-section weak-axis column bending connection

  • Lu, Linfeng;Xu, Yinglu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.31-44
    • /
    • 2018
  • This paper reports a novel steel beam-to-column connection suitable for use in the weak axis of I-section column. Monotonic and cyclic loading experimental investigations and numerical analysis of the proposed weak-axis connection were conducted, and the calculation procedure of the beam-column relative rotation angle and plastic rotation angle was developed and described in details. A comparative analysis of mechanical property and steel consumption were employed for the proposed I-section column weak-axis connection and box-section column bending connection. The result showed that no signs of fracturing were observed and the plastic hinge formed reliably in the beam section away from the skin plate under the beam end monotonic loading, and the plastic hinge formed much closer to the skin plate under the beam end cyclic loading. The fracture of welds between diaphragm and skin plate would cause an unstable hysteretic response under the column top horizontal cyclic loading. The proposed weak-axis connection system could not only simplify the design calculation progress when I-section column is adopted in frame structural design but also effectively satisfy the requirements of 'strong joint and weak member', as well as lower steel consumption.

Experimental study on two types of new beam-to-column connections

  • Ma, Hongwei;Jiang, Weishan;Cho, Chongdu
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.291-305
    • /
    • 2011
  • The new structure consisting of continuous compound spiral hoop reinforced concrete (CCSHRC)column and steel concrete composite (SCC) beam has both the advantages of steel structures and concrete structures. Two types of beam-to-column connections applied in this structural system are presented in this paper. The connection details are as follows: the main bars in beam concrete pass through the core zone for both types of connections. For connecting bar connection, the steel I-beam webs are connected by bolts to a steel plate passing through the joint while the top and bottom flanges of the beams are connected by four straight and two X-shaped bars. For bolted end-plate connection, the steel I-beam webs are connected by stiffened extended end-plates and eight long shank bolts passing through the core zone. In order to study the seismic behaviour and failure mechanisms of the connections, quasi-static tests were conducted on both types of full-scale connection subassemblies and core zone specimens. The load-drift hysteresis loops show a plateau for the connecting bar connection while they are excellent plump for bolted end-plate connection. The shear capacity formulas of both types of connections are presented and the values calculated by the formula agree well with the test results.

삼각형병동의 결합유형에 관한 건축계획적 연구 (A Study on the Architectural Planning of Joint Pattern in the Triangular Type Ward)

  • 김길채
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권2호
    • /
    • pp.59-67
    • /
    • 2006
  • The purpose of this study is to present the research data to improve the quality of triangular ward in general hospital in Korea. Drawing documents analysis were used to examine the condition of ward. This study in focused on patient room and atrium according to connection type of triangular ward, allocation of NS, module and direction of patient room. The results of this study is as follows; Triangular ward has two joint pattern(conner and conner, side and side). Conner and conner joint pattern is good at planning of lighting than side and side joint pattern. Triangular ward can has different module system in each side. Allocation of NS is important factor which is focused on patient relationship or ward control.

  • PDF

연속 프리캐스트 합성바닥판의 비탄성 거동 (Inelastic Behavior of Continuous Precast Composite Slabs)

  • 심창수;정영수;민진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.447-450
    • /
    • 2005
  • A prefabricated composite hollow slab with perforated I-beams was suggested for the replacement of deteriorated concrete decks or the construction of new composite bridges with long-span slabs. Composite slabs with embedded I-beams have considerably higher stiffness and strength. For the application of prefabricated composite slabs to bridges, joints between slabs should satisfy the requirements of the ultimate limit state and the serviceability limit state. In this paper, three types of the detail for loop joints were selected and their structural performance in terms of strength and crack control was investigated through static tests on continuous composite slabs. A main parameter was the detail of the joint, such as an ordinary loop joint and loop joint with additional reinforcements. Even though there was no connection of the steel beams at the joints, the loop joints showed good performance in terms of strength. In terms of crack control, the loop joint with additional reinforcements showed better performance. In ultimate limit state, the continuous composite slabs showed good moment redistribution and ductility.

  • PDF

돌기형 접합 보강재를 이용한 옥상 노출 복합방수의 조인트 시공방법에 관한 연구 (Sheet Jointing Method of the Roof Exposed Hybrid Waterproofing Using the Bump-type Joint Reinforcement)

  • 김명지;안기원;김동춘;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2018
  • Seat waterproofing materials applied to the roof of a building concrete structure inevitably produce joints and are applied with opposite dam joints or overlapping joints depending on the waterproof material applied to the top of the sheet. In this case, the joint performance is determined by the material at the top, rather than by the superimposed joint. In order to solve this problem, various reinforcements have been used to apply to the connecting parts of the opposite dam, but the problem of attachment between different materials or the lack of reinforcement of the joint tape has not been solved. Therefore, for the purpose of securing tensile performance to the joints, this study is used as a reinforcement for the joints of PP materials with high tensile performance and as a reinforcement for nylon materials.

  • PDF

임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향 (Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength)

  • 전미현;정창모;전영찬;엄태관;윤지훈
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.269-281
    • /
    • 2008
  • 골유착성 임플란트 보철물에서 피로나 과하중에 의해 보철유지 나사나 지대주 나사의 파절, 보철물의 파절, 또는 고정체의 파절 등과 같은 기계적 강도와 연관된 문제점이 발생할 가능성이 높다. 임플란트 시스템의 기계적인 강도에 영향을 주는 요소에는 고정체와 나사의 직경, 재료적 특성, 연결부 디자인, 지대주 디자인 등이 있으며, 이 중 임플란트 고정체와 지대주간의 연결부 디자인은 임플란트 시스템의 기계적인 연결상태와 연결부 안정성을 결정하는 주요소이다. 대부분의 기계적 강도에 관한 연구에서처럼 단일하중에 의한 압축굽힘강도나, 단기적인 반복하중 후의 결과만을 평가하여 임플란트 시스템의 장기적인 안정성을 예측하기에는 한계가 있다. 연구 목적: 이에 본 연구에서는 external butt joint와 internal conical joint를 갖는 임플란트 시스템(오스템사)의 연결부 디자인에서 각각 다른 두 가지 지대주를 사용하여, 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향을 압축굽힘강도는 물론 내구성한계를 측정하여 알아보고자 하였다. 연구 재료 및 방법: External butt joint인 US II에서는 통상적인 UCLA 지대주 형태의 Cemented abutment(BJT)와 굽힘 저항성을 증가시키기 위해 나사 두부가 지대주 상단에 위치하도록 설계된 Safe abutment(BJS)를, internal conical joint인 SS II에서는 one-piece형의 Solid abutment(CJO)와 two-piece형의 ComOcta abutment(CJT)를 지대주로 사용하였다. ISO 규정을 참고하여 단일 임플란트, 변연골 흡수, 그리고 $30^{\circ}$ 경사하중 조건에서 압축굽힘강도와 내구성한계를 측정하였고 실패 양상을 관찰한 결과 다음과 같은 결론을 얻었다. 결과 및 결론: 1. 압축굽힘강도는 BJS군(1392.0N), CJO군(1261.8N), BJT군(1153.2N), 그리고 CJT군(1110.2N) 순으로 낮아졌으며(P<.05), CJT군과 BJT군 사이에는 차이가 없었다(P>.05) 2. 내구성한계는 CJO군(600N), CJT군(453N), BJS군(360N) 그리고 BJT군(300N) 순으로 낮아졌다. 3. 압축굽힘강도는 연결부 디자인 또는 지대주 디자인에 따라 차이를 보였으며, 내구성한계에 있어서는 연결부 디자인이 더 주된 요소로 작용하였다.

A new statistical approach for joint shear strength determination of RC beam-column connections subjected to lateral earthquake loading

  • Kim, Jaehong;LaFavet, James M.;Song, Junho
    • Structural Engineering and Mechanics
    • /
    • 제27권4호
    • /
    • pp.439-456
    • /
    • 2007
  • Reinforced concrete (RC) joint shear strength models are constructed using an experimental database in conjunction with a Bayesian parameter estimation method. The experimental database consists of RC beam-column connection test subassemblies that maintained proper confinement within the joint panel. All included test subassemblies were subjected to quasi-static cyclic lateral loading and eventually experienced joint shear failure (either in conjunction with or without yielding of beam reinforcement); subassemblies with out-of-plane members and/or eccentricity between the beam(s) and the column are not included in this study. Three types of joint shear strength models are developed. The first model considers all possible influence parameters on joint shear strength. The second model contains those parameters left after a step-wise process that systematically identifies and removes the least important parameters affecting RC joint shear strength. The third model simplifies the second model for convenient application in practical design. All three models are unbiased and show similar levels of scatter. Finally, the improved performance of the simplified model for design is identified by comparison with the current ACI 352R-02 RC joint shear strength model.