• Title/Summary/Keyword: jet velocity

Search Result 835, Processing Time 0.028 seconds

Association study analysis of phospholipase C zeta gene polymorphism forsperm motility and kinematic characteristics in liquid semen of Boar (Phospholipase C zeta 유전자의 유전적다형성과 돼지 액상정액의 운동학적 특성과의 연관성 분석)

  • Jeong, Yong-dae;Jeong, Jin-Young;Sa, Soo-Jin;Kim, Ki-Hyun;Cho, Eun-Seok;Yu, Dong-Jo;Park, Sungk-won;Jang, Hyun-Jun;Woo, Jae-Seok;Choi, Jung-Woo
    • Journal of Embryo Transfer
    • /
    • v.31 no.3
    • /
    • pp.293-297
    • /
    • 2016
  • For evaluating the boar semen quality, sperm motility is an important parameter because the movement of sperm indicates active metabolism, membrane integrity and fertilizing capacity. Phospholipase C zeta (PLCz) is important enzyme in spermatogenesis, but the effect has not been confirmed in pigs yet. Therefore, this study was aimed to analyze their association with sperm motility and kinematic characteristics. DNA samples from 124 Duroc pigs with records of sperm motility and kinematic characteristics [total motile spermatozoa (MOT), curvilinear velocity (VCL), straight-line velocity (VSL), the ratio between VSL and VCL (LIN), amplitude of lateral head displacement (ALH)] were subjected. A SNP in non-coding region of PLCz g.158 A > C was associated with MOT (p < 0.05), VCL (p < 0.01), LIN (p < 0.01) and ALH (p < 0.05) in Duroc population. Therefore, we suggest that the intron region of the porcine PLCz gene may be used as a molecular marker for Duroc boar semen quality, although its functional effect was not defined yet. Whether the association is due to the candidate gene or not require further verification. Thus, it will be of interest to continue association studies in the regions surrounding those genes.

Association study analysis of CD9 as candidate gene for Duroc pig sperm motility and kinematic characteristics (두록 정자 운동학적 특성과 후보유전자 CD9 유전자와의 연관성 분석)

  • Jeong, Yong-dae;Jeong, Jin-Young;Kim, Ki-Hyun;Cho, Eun-Seok;Yu, Dong-Jo;Choi, Jung-Woo;Jang, Hyun-Jun;Park, Sungk-won;Sa, Soo-Jin;Woo, Jae-Seok
    • Journal of Embryo Transfer
    • /
    • v.31 no.3
    • /
    • pp.281-285
    • /
    • 2016
  • Cluster-of-differentiation antigen 9 (CD9) gene expressed in the male germ line stem cells is crucial for sperm-egg fusion, and was therefore selected as a candidate gene to investigate Duroc boar semen motility and kinematic characteristics. This study was performed to investigatetheir association with semen motility and kinematic characteristics. DNA samples from 96 Duroc pigs with records of sperm motility and kinematic characteristics [Total motile spermatozoa (MOT, $82.27{\pm}5.58$), Curvilinear velocity(VCL, $68.37{\pm}14.58$), Straight-line velocity(VSL, $29.06{\pm}6.58$), the ratio between VSL and VCL(LIN, $47.36{\pm}8.42$), Amplitude of Lateral Head displacement(ALH, $2.88{\pm}0.70$)] were used in present study. A single nucleotide polymorphism (g.358A>T) in intron 6 was associated with MOT, VCL, VAP and ALH in Duroc population (p<0.05). Therefore, we suggest that the porcine CD9 may be used as a molecular marker for Duroc boar semen quality, although its functional effect was not clear yet. These results will improve the understanding of the functions of the CD9 in spermatogenesis within the reproductive tracts, and will shed light on CD9 as a candidate gene in the selection of good sperm quality boars.

A numerical study on the characteristics of the smoke movement and the effects of structure in road tunnel fire (도로터널 화재시 연기의 전파특성과 구조체에 미치는 영향에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Oh, Byung-Chil;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.289-300
    • /
    • 2013
  • This study numerically considered the characteristic of smoke movement and the effect of hot smoke gas on tunnel wall surface temperature during road tunnel fire under boundary condition of fire growth curve that is applied to fire analysis in road tunnels. The maximum heat release rate were 20 MW and 100 MW and tunnel air velocities were 2.5 m/s and velocity induced by thermal buoyancy respectively, also the cooling effect of tunnel wall was considered. As results, when tunnel air velocity was constant at 2.5 m/s during tunnel fire, due to the cooling effect of tunnel wall, the smoke layer was rapidly descent after some distance and it flowed the same patterns at the downstream. When heat release rate was 100 MW (and jet fan was not installed), the maximum temperature of tunnel wall surface has risen up to $615^{\circ}C$. The heat transfer coefficient of tunnel wall surface was varied from 13 to $23W/m^2^{\circ}C$ approximately.

Improvement of Rectangle Sedimentation basin using the Moving Baffle (이동식 정류장치를 이용한 횡류식 침전지 침전효율 개선 연구)

  • Cho, Young-Man
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.726-731
    • /
    • 2005
  • Sedimentation is treated as the most important unit process in waterworks, and plays great role on turbidity removal efficiency. Rectangle sedimentation basin is the most widely accepted sedimentation process. But it has some problems with short-circuit flow and density flow caused by temperature and influent turbidity variation. To solve these problems, installation of rectification wall was suggested, but not generally fully accepted in field. Because hole of rectification wall cause jet flow. In this research, use of moving baffle was investigated. Moving baffle was designed to induce uniform velocity at every section of water flow. The baffle walls was made from soft fiber materials. The baffle walls with flow of sedimentation basin moves at same speed. It is like that it controls density flow and short-circuit flow and induce uniform velocity at every section of water flow in sedimentation basin. When moving baffle was operated retention time of sedimentation basin was extended to 1 hours. When it talked again and the effluent time of highest concentration of the chlorine ion from 100 minutes was extended to 160 minutes. Turbidity removal efficiency was tested with different operation modes(continuous and batch) with influent turbidity and retention time. It was revealed that turbidity removal efficiency carl be improved up to 36%(continuous mode) and 58%(batch mode) respectively. Consequently if moving baffle introduces in Rectangle sedimentation basin, it forecasts that the turbidity improvement above 30% will be possible.

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF

CPFD Simulation of Bubble Flow in a Bubbling Fluidized Bed with Shroud Nozzle Distributor and Vertical Internal (CPFD 시뮬레이션을 통한 Shroud 노즐 및 수직 구조물이 설치된 기포 유동층 반응기 내에서의 기포 흐름 해석)

  • Lim, Jong Hun;Bae, Keon;Shin, Jea Ho;Lee, Dong Ho;Han, Joo Hee;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.678-686
    • /
    • 2016
  • The effect of internal and shroud nozzle distributor to bubbling fluidized beds which has the size of $0.3m-ID{\times}2.4m-high$ column was modeled by CPFD (Computational Particle-Fluid Dynamics). Metal-grade silicon particles (MG-Si) were used as bed materials which have $d_p=149{\mu}m$, ${\rho}_p=2,325kg/m^3$ and $U_{mf}=0.02m/s$. Total bed inventory and static bed height were 75 kg and 0.8 m, respectively. Effect of vertical internal on the bubble rising velocity was investigated. Bubbles were split by internal when the axial position of the internal from the distributor, z = 0.45 m. Bed pressure drop and axial solid holdup were not affected by internal. However, in the case that axial distance of internal from distributor was too close to jet penetration length, bubbles were not separated and bypassed internal, and faster than without internal or z = 0.45 m.

Design of Gun Launched Ramjet Propelled Artillery Shell with Inviscid Flow Assumption (비점성 유동을 가정한 포 발사 램제트 추진탄 설계)

  • Kang, Shinjae;Park, Chul;Jung, Woosuk;Kwon, Taesoo;Park, Juhyeon;Kwon, Sejin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.52-60
    • /
    • 2015
  • Operation area of corps was expanded under military reformation, and extending range of 155 mm howitzer became important issue. New approach is needed to extend range to 80 kim. Ramjet engine is air breathing engine, and it can provide specific impulse several times more than solid rocket motor so that range is extended using same weight of propellant. If the ramjet engine is gun-launched system, it does not require any other booster because muzzle velocity is near Mach 3. Especially solid fuel ramjet (SFRJ) does not have any moving part so that it is favorable for gun-launching system which is under high stress during launching. In this paper, we design air intake, combustion chamber, and nozzle of 155 mm gun launched ramjet propelled artillery shell with inviscid flow assumption. We conduct parameter study to have range more than 80 km, and maximum high explosive volume.

Estimates of Surface Explosion Energy Based on the Transmission Loss Correction for Infrasound Observations in Regional Distances (인프라사운드 대기 전파 투과손실 보정을 통한 원거리 지표폭발 에너지 추정)

  • Che, Il-Young;Kim, Inho
    • Journal of the Korean earth science society
    • /
    • v.41 no.5
    • /
    • pp.478-489
    • /
    • 2020
  • This study presents an analysis of infrasonic signals from two accidental explosions in Gwangyang city, Jeonnam Province, Korea, on December 24, 2019, recorded at 12 infrasound stations located 151-435 km away. Infrasound propagation refracted at an altitude of ~40 km owing to higher stratospheric wind in the NNW direction, resulting in favorable detection at stations in that direction. However, tropospheric phases were observed at stations located in the NE and E directions from the explosion site because of the strong west wind jet formed at ~10 km. The transmission losses on the propagation path were calculated using the effective sound velocity structure and parabolic equation modeling. Based on the losses, the observed signal amplitudes were corrected, and overpressures were estimated at the reference distance. From the overpressures, the source energy was evaluated through the overpressure-explosive charge relationship. The two explosions were found to have energies equivalent to 14 and 65 kg TNT, respectively. At the first explosion, a flying fragment forced by an explosive shock wave was observed in the air. The energy causing the flying fragment was estimated to be equivalent to 49 kg or less of TNT, obtained from the relationship between the fragment motion and overpressure. Our infrasound propagation modeling is available to constrain the source energy for remote explosions. To enhance the confidence in energy estimations, further studies are required to reflect the uncertainty of the atmospheric structure models on the estimations and to verify the relationships by various ground truth explosions.

The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation (터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석)

  • Lee, Chang-Woo;Suh, Ki-Yoon;Kim, Jung-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.325-334
    • /
    • 2006
  • Understanding the airflow characteristics within the canopy structure installed between closely adjacent tunnels either for light adaptation or for protection from snow hazards is required for the normal ventilation as well as safety system design. Grade, horizontal alignment, cross-sectional area and shape are known to substantially influence the fire smoke behavior and their influences raise great concern for the safety design. This paper aims at studying the effects of tunnel geometrical characteristics and canopy installation on the ventilation and fire propagation through CFD analysis. In the case of 145m long canopy, 50% opening ratio is preferred with respect to the airflow pattern and ventilation efficiency. When a 20MW fire occurs in a 1.8km-long tunnel and four 1250mm reversible jet fans are instantly turned on, smoke concentration at 40m downstream of the fire decrease 13% for the upgrade tunnel with 2% gradient and increases 20% for -2% gradient, compared to the standard horizontal tunnel. Backlayering is observed within 45m-long segment toward the entrance in 2% down-graded tunnel. In a rectangular tunnel, there is no significant difference of smoke concentration as well as velocity profile from the standard crown tunnel. Three-laned tunnel shows lower level of both profiles and backlayering is detected up to 50m upstream of the fire, while the risky situation rapidly disappears thereafter.

Measurement of Mutual Solubility of High-pressure Gaseous Fire Extinguishing Agents(HFCs) and Nitrogen (고압가스계 소화약제(HFCs계열)와 질소의 상호용해도 측정)

  • 임종성;박지영;이병권;김재덕;이윤용
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.26-31
    • /
    • 2002
  • Bromotrifluoromethane(halon-1301) and bromochlorodifluoromethane(halon-1211) have been widely used as a clean fire extinguishing agents due to their outstanding properties. However, production and use of halon are currently being phased out under an international agreements Montreal Protocol because of global environmental concerns and HFCs have been considered as promising alter-natives for the replacement of halon since their ozone depletion potentials are low. The vapor-liquid equilibrium data are required as important basic information in evaluating the solubility of clean fire extinguishing agents and determining their optimal compositions. In this work, we chose HFCs such as HFC-22 HFC-125, and HFC-l34a for gaseous fire extinguishing agents and nitrogen as a pressurization gas for a proper jet velocity of these agents. Phase equilibria for binary mixtures of nitrogen/HFC-22, nitrogen/HFC-125, and nitrogen/HFC-l34a were measured in the temperature range from 283.15K to 303.15K. For equilibrium measurement, we used a circulation type apparatus in which both vapor and liquid phases were continuously recirculated. The experimental data were relatively well correlated with the Peng-Robinson equation of state with Wong-Sandier mixing rules.