• Title/Summary/Keyword: jet pump

Search Result 102, Processing Time 0.025 seconds

Improvement of the $SO_{x}$ Removal by Adding Dibasic Acids into the JBR FGD Process

  • Lee, Byeong-Kyu;Jeon, Sang-Ki;Cho, Seong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.157-162
    • /
    • 2001
  • Jet Bubbling Reactors(JBRs) were operated for the removal of SO$_{x}$ in flue gases produced from many electric power plants. However, many JBR flue gas desulfurization (FGD) facility faced a decrease of SO$_{x}$ removal efficiency and an increase of scale problems with continuous operations. We increased alkalinity of the SO$_{2}$ absorbing medium by adding the dibasic acids (DBAs) to solve these problems more effectively. The SO$_{2}$ removal efficiency, the purity of CaCO$_{3}$ and COD of the wastewater was measured to identify the addition effects of DBAs (150, 200, 250, and 400 ppm) for 2hr in a day into the JBR attached to the large-scale power plants (400 MW$\times$3). Addition of the DBAs resulted in the improvement of the SO$_{2}$ removal efficiency from 2 to 5% and the purity of the gypsum from 1 to 2%; these improvement were due to the alkalinity increase of the absorbing medium and the reduction of a proportion of un-reacted CaCO$_{3}$, respectively. Also, the scale problems formed by un-reacted CaCO$_{3}$ inside the reaction zone of the JBR were substantially reduced. Even though the effluent COD of the wastewater slightly increased from 10~15 to 18~36 mg/l and the erosion problems in the injection pump and duct occurred, this method of increasing SO$_{2}$ removal efficiency by adding the DBAs could be considered as a profitable approach.ach.

  • PDF

A Modeling about Penetration Behavior of Diesel Engine Liquid Fuel Spray (디젤기관의 분무선단 도달거리에 관한 모델링)

  • 안수길;배종욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.140-152
    • /
    • 1989
  • The study on the penetration of sprays during the initial phase of injection period, i.e. ignition delay period, in high speed small D.I. diesel engines are strongly affected by such behavior. To investigate the penetration of the sprays injected through single cylinderical orifice, a mathematical model was developed and compared with experimental results. In this model, radial heterogeneity of fuel density in the spray, transiency of injection pressure difference, and spray outrunning phenomenon were considered simultaneously. Experiments on the behaviors of sprays in the high pressure air chamber were conducted at various injection pressure differences and different levels of back air pressure. The behaviors of sprays injected into the chamber through the conventional Bosch injection pump were visualized with side stroboscopic illumination. Comparison of the experimental results with predictions from the mathematical model confirmed the validity of the model. It was also found that during the initial phase of the injection period the penetration of sprays vs. time appeared to have two transition points; one corresponded to disintegration point of liquid fuel jet, the other to the beginning of steady state injection.

Development of a Garlic Peeling System Using High-Pressure Water Jets (I) - Peeling tests with high-pressure plunger pumps and flat-spray nozzles - (습식 마늘박피 시스템 개발 (I) - 고압 플런저 펌프와 부채꼴 분사노즐을 이용한 박피 실험 -)

  • 양규원;배영환;백성기
    • Journal of Biosystems Engineering
    • /
    • v.29 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • This research was conducted to test the feasibility of utilizing high-pressure water jets of over 1.0㎫ as a means of breaking and peeling garlic bulbs. High-pressure plunger pumps and flat-spray nozzles of varying orifice diameters and spray angles were utilized to supply water jets into a prototype peeling chamber made of transparent acrylic plates. Water jets were discharged from a total of six nozzles installed in such a way that three parallel nozzles face the other three. The cross-sectional area of the peeling chamber and the installation angle of the nozzles had critical effects on peeling performance. Small cross-sectional area was required so that total impact force of water jets on garlic could be increased. The optimum installation angles were around 4, 8, and 16$^{\circ}$ for the nozzles having 15, 40, and 65$^{\circ}$ spray angles, respectively. Best performance with 61.4% of completely-peeled garlics was obtained at a pressure of 1.94㎫ and a flow rate of 9.07 $\ell$/min for each nozzle. The peeling efficiency of the system was generally unsatisfactory due to the limited flow rate of the plunger pumps utilized. For better performance, it is recommended to increase flow rate while reducing operating pressure by utilizing other type of pumps.

Spray Characteristics of Supersonic Liquid Jet by a Nozzle Geometry of Miniature High-Pressure Injection System (축소형 초고압 분사 시스템의 노즐 형상에 따른 초음속 액체 제트 분무 특성에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.177-180
    • /
    • 2010
  • Two-stage light gas gun, sorted with Ballistic Range System, is used to research spray characteristics of supersonic liquid jets. When high pressure tube was pressurized to the 135 bar, diaphragm films which composed with OHP film are ruptured. Expansion gases accelerate a projectile approximately 250 m/s at the exit of pump tube. And accelerated projectile collides with liquid storage part and liquid jets were injected into supersonic conditions. Supersonic liquid jets show the multiple jets and generate shockwave at the forward region of jets. Supersonic liquid jets of speed and shockwave angle have different value at each case. Supersonic liquid jets with minimum velocities are injected with M=1.53 at the geometry condition of L/d=23.8.

  • PDF

Development of a 2-fluid Jet Mixer for Preventing the Sedimentation in Livestock Liquid Manure Storage Tank (가축분뇨액비저장조 침전물 퇴적 방지를 위한 2류체 제트노즐식 교반장치 개발에 관한 연구)

  • Yu, B.K.;Hong, J.T.;Kim, H.J.;Kweon, J.K.;Oh, K.Y.;Park, B.K.
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.207-220
    • /
    • 2012
  • There are around 7,500 manure tanks to treat the manures from pigs in Korea. In the tank, there are too much sediments deposited on the base and wall, which causes low efficiency of stock capacity and manure fermentation. In order to minimize sediments and to ferment manure effectively, we developed a 2-fluid jet mixer for mixing sediments in liquid livestock manure tank. For developing the prototype, we tested a factorial experimental system with various nozzles, and simulated CFD models with two kinds of nozzle arrangement. From the results of factorial experiment and CFD simulation, we concluded the dia. ratio of primary : secondary nozzle should be 1:2 and the nozzles should be arranged at the same distances toward to the circumferential direction. With this results, we manufactured a 2-fluid jet mixer which is consists of four 2-phase nozzles, centrifugal slurry pump and root's type air blower. And, we carried out the performance test of the prototype in the round shaped liquid manure tank in the farm. The performance test results showed that the uniformity of TS (Total Solid) and VS (Volatile Solid) was raised from 21.3 g/L, 13.3 g/L In steady state to TS and VS to 23.0 g/L, 14.1 g/L in the mixing operation. Therefore, we could conclude that the prototype of 2-fluid mixer could make the solid material which could be sediments in the tank not to be deposited in the tank and to be contacted to air bubbles which could enhance the efficiency of the fermentation of livestock manure.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Follicular Stimulation and Laparoscopic Ovum Pick-up (LOPU) in Repeatedly Superovulated Korean Black Goats (반복적인 과배란 처치 경험이 있는 한국흑염소에서 난포 자극 및 복강경을 이용한 난포란 채취(LOPU))

  • Lee, Yong-Boum;Lee, Doo-Soo;Cho, Sang-Cheol;Shin, Sang Tae
    • Journal of Embryo Transfer
    • /
    • v.29 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Laparoscopic ovum pick-up (LOPU) is a convenient method for collecting oocytes in small ruminants. LOPU has the advantage of being a less invasive means of oocyte collection, thereby allowing for a repeated usage of the oocyte donor animals. A total of 25 Korean black goats were used in the winter season (December to February) and LOPU was applied to the goats which had been treated for superovulation more than two times during the last twelve months. Estrus was synchronized with an intravaginal insert containing 0.3 g progesterone for 10 to 12 days. Ovaries were hyperstimulated with eCG 1,000 IU oneshot, FSH with eCG (50 mg / 1,000 IU; 70 mg / 500 IU; 70 mg / 1,000 IU) oneshot or FSH multiple-shot with eCG oneshot ($20mg{\times}6/300IU$) given intramuscularly 72 h prior to LOPU. For these groups, the number of follicles (mean ${\pm}$ SEM) observed which developed to larger than 2 mm in diameter were $1.6{\pm}2.5$, $4.3{\pm}3.1$, $5.5{\pm}4.2$, $6.6{\pm}2.1$ and $8.8{\pm}7.8$, respectively. Oocytes were aspirated by using OPU needles and a vacuum pump. The overall oocyte retrieval rates were 41.4%. Oocytes were matured in TCM-199 supplemented with 10% (w/v) bovine serum albumin + $10{\mu}g/ml$ FSH + $1{\mu}g/ml$ $17{\beta}$-estradiol for 27 h at $39^{\circ}C$ in 5% $CO_2$ in air. Oocytes were parthenogenetically activated by ionomycin combined with 6-diethylaminopurine (6-DMAP). Total oocyte maturation and cleavage rate were 67.3% and 78.8%, respectively. In summary, LOPU is a useful oocyte collection method in Korean black goats that can provide immature oocytes for transgenesis or nuclear transfer.

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Analysis of Volatile Organic Compounds Produced from Incineration of Papers at 600°C (600°C에서 제지류 소각시 발생하는 휘발성 유기화합물 농도분석 연구)

  • 이병규;조정범
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1109-1116
    • /
    • 2002
  • This study analyzed concentrations of volatile organic compounds (VOCs) produced from incineration of papers at $600^{\circ}C$. The papers used in this study included A4 papers (new, printed with ink-jet, printed with carbon), newspapers (printed with bean oil, printed with a general newspaper ink), packaging box, document envelope, single-use paper cup, and cosmetic tissue. Papers were heated from room temperature upto $600^{\circ}C$ providing air inside of the electric furnace and then they were oxidized for 80 minutes at $600^{\circ}C$ maintaining the same air supply. VOCs emitted from the incineration process were sampled using an air sampling pump and bags for 160 minutes and then the components and concentrations of the VOCs were analyzed by a CC-MS. The most prominent chemical structure of the Vous identified from incineration of the papers was furans and then furans were followed by aromatics and aliphatic alkenes. About 40% of the identified VOCs contained double bonds, which have relatively a high ozone (ground level) formation potential, within their molecular structure. Also, some cancer suspecting compounds like benzene, dichlorormethane and chloroform were identified.