• Title/Summary/Keyword: jar-test

Search Result 154, Processing Time 0.029 seconds

Evaluation of Local Velocity Gradient and Total Mass transfer Time at Various Rotating Velocity by Using Computational Fluid Dynamics (CFD를 이용한 패들교반속도에 따른 속도경사 및 총물질전달시간 산정)

  • Jun, Hang-Bae;Tian, Dong-Jie;Hong, Ki-Won;Han, Hong-Sig;Park, Byeong-Chang
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.166-174
    • /
    • 2014
  • Velocity gradient, G, a measure of the average velocity gradient in the fluid has been applied for complete mixing of chemicals in mechanical mixing devices. G values were calculated by the power input transferred to fluid in turbulent and transient range. Chemical reactions occur so fast that total mass transfer time required for even distribution of the chemicals determine the overall reaction time. The total mass transfer time is composed of the time for complete mixing through the reactor and for diffusion of the chemicals into the eddy. Complete mixing time was calculated by CFD (computer fluid dynamics) and evaluated by tracer tests in 2 liter jars at different rotating speeds. Turbulent range, Reynolds number above 10,000 in regular 2 liter jars occurred at revolution speed above 100 rpm (revolution per minute), while laminar range occurred at revolution speed below 10 rpm. A typical range of rotating speed used in jar tests for water and wastewater treatment was between 10 and 300 rpm, which covered both transient and turbulent range. G values supplied from a commercial jar test apparatus showed big difference from those calculated with power number specially in turbulent range. Diffusion time through eddy decreased 1.5 power-law of rotating speed. Complete mixing time determined by pumping number decreased increases in rotating speed. Total mass transfer time, finally, decreases as rotating speed increases, and it becomes 1 sec at rotating speed of 1,000 rpm. Complete mixing times evaluated from tracer tests showed higher than those calculated by power number at higher rotating speed. Complete mixing times, however, calculated by CFD showed similar to those of experimentally evaluated ones.

Production of L-Tryptophan by Auxotrophs Derived from Analogue- resistant Mutants of Escherichia coli (영양요구성 대장균 변이주를 이용한 L-트립토판 생산)

  • Lee, In-Young;Kim, Jae-Hi;Kwak, Moo-Young;Lee, Hosull;Lee, Sun-Bok
    • Microbiology and Biotechnology Letters
    • /
    • v.16 no.5
    • /
    • pp.407-412
    • /
    • 1988
  • In order to increase the tryptophan productivity of E. coli SB1007, a mutant resistant to sulfanilamide was isolated and then a tyrosine auxotroph TY-90 was derived from the sulfanilamide-resistant mutant SA3-39-16. In the test-tube culture a quantitative amount of tryptophan was accumulated in strain TY-90 but in a jar fermentor culture the productivity was lower as compared to the level obtained by the parent strain. From the double auxotrophic mutant SB2756, a revertant resistant to 2, 000$\mu\textrm{g}$/$m\ell$ of $\beta$-thienylalanine, TA 40-10, was selected and then phenylalanine auxotrophs were derived from the revertant strain TA-40-10. One of the phenylalanine auxotrophs, TP-4, accumulated 3.7g/$\ell$ of L-tryptophan after 71-hr cultivation in a jar fermentor experiment.

  • PDF

Synthesis of Improved Polyaluminumchloride and Its Coagulation Properties (개선된 폴리염화알루미늄의 합성 및 응집 특성)

  • Choi, Yong-Wook
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.3
    • /
    • pp.273-282
    • /
    • 2004
  • The synthetic technology of improved polyaluminiumchloride (IPAC) similar to characteristics of PACS was established with minimum expense for modifying existing production line. The conditions for activating silicate was studied before the synthesis of IPAC, and the IPAC was synthesised with raw materials such as aluminumhydroxide and concentrated hydrochloric acid, followed by adding activated silicate and alginate. The specification of product, chemical structure, and coagulating properties were tested by using specification testing method, instrumental analytical method, and Jar tester, respectively. As a result, the product, IPAC, contained aluminium oxide content more than 17%, and no precipitation was shown at all while the IPAC solution was preserved, and the larger floc and faster coagulation were represented compared to existing PAC under the same conditions. It was suggested that these synthetic technology could be applied to the existing production line for producing PAC without approximately cost raising factor because of adding sulfuric acid-activated silicate instead of sodium sulfate.

Cross-cultural Consumer Acceptance of Cooked Spinach ($Sigeumchi-namul$) according to Blanching Time (데치는 시간에 따른 시금치나물의 교차 문화적 소비자 기호도)

  • Yang, Jeong-Eun;Chung, Seo-Jin;Kim, Hang-Ran;Kim, Kwang-Ok;Chung, La-Na
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.22 no.2
    • /
    • pp.190-198
    • /
    • 2012
  • This research evaluated and analyzed the level of acceptability of spinach according to blanching time by testing consumer taste of corresponding countries for the purpose of globalizing Korean food. General taste, appearance, flavor, and texture of spinach blanched for 20 seconds were highly evaluated by Koreans and Japanese ($p$<0.05), who are used to the method of slightly blanching, mixing, and eating spinach. On the other hand, general taste, appearance, flavor, and texture of spinach blanched for 5 minutes was highly evaluated by the French ($p$<0.05), who are used to eating boiled spinach. Concerning the result of JAR, there were clear differences in hardness and boiling level according to country among spinach samples, even though they were blanched for the same time and mixed with the same spices. Koreans and Japanese evaluated that hardness and boiling level of spinach blanched for 20 seconds were proper, whereas the French evaluated that spinach scalded for 20 seconds was too raw and crispy. Under the same context, French consumers evaluated that hardness and boiling level of spinach blanched for 5 minutes was proper, whereas Koreans and Japanese evaluated that spinach blanched for 5 minutes was boiled too much. These results show that familiarity level is an important driver of affecting the preference levels for three kinds of spinach according to country.

A Study on the Allowances of Aircraft Landing Distance (항공기 착륙거리의 여유분 산정에 관한 연구)

  • Noh, Kun-Soo;Kim, Woong-Yi
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • Among the phases of flight operations pilots feel much pressure in landing segment. There is a number of factors affecting landing safety while pilots reduce aircraft speeds and make a touchdown and stop completely. If runway length is sufficient for landing, there maybe is no problem. But it is not the case all the time. So it is necessary to confirm whether landing performance is within limits or not. Required landing distance is actual landing distance demonstrated by flight test pilot plus allowances for average airline pilots. FAR(Federal Aviation Regulations) AFM certification is based upon manual landing for dry and wet runway. Other runway conditions are not the certification basis. JAR dictates even contaminated/slippery runway is included by prescribed allowances. Automatic landing is not certification basis, so actual landing distances are provided. In this paper I would like to analyze distance allowances included in each type of runway condition. In addition there is no regulation about allowances for specific runway condition, I would suggest adequate allowances for that case.

Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities (하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토)

  • Jang, Yeoju;Jung, Jinhong;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

Treatment of Dye-Processing Wastewater by Chemical Precipitation (화학적 침전공정에 의한 염색가공폐수의 처리)

  • Han, Myung-Ho;Huh, Man-Woo;Kim, Jeong-Mog;Lee, Jin-Sik;Lim, Hak-Sang
    • Textile Coloration and Finishing
    • /
    • v.9 no.6
    • /
    • pp.26-32
    • /
    • 1997
  • In order to remove the pollutants effectively in the dye-processing wastewater by chemical precipitation, coagulation and flocculation test was carried out using several coagulants on various reaction conditions. It was found that the Ferric sulfate was best coagulant for the treatment of mixed dye-processing wastewater. When the Ferric sulfate dosage was 1,100mg/$\ell$, the COD removal rate was very high(50%), and the color was removed very effectively. The COD was decreased relatively well up to 40%, when Alum was dosed as coagulant. But it was difficult to remove the color effectively. Test results about COD removal for the Ferrous sulfate and the Ferric chloride used were mostly same as those of the Alum used. However, the color removal by the Ferrous sulfate was much better than the case of the Alum or the Ferric chloride. It was found that the COD removal was increased and the sludge yield was decreased by pH control before polymer flocculant addition, during the jar test for the Ferrous sulfate and the Ferric sulfate as a coagulant.

  • PDF

The Safety and Analgesic Effect of Datura Flos Pharmacopuncture in Sprague-Dawley Rats

  • Jun, Seungah;Lee, Yun Kyu;Lee, Bong Hyo;Kim, Jae Soo;Lee, Hyun-Jong
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.147-153
    • /
    • 2019
  • Background: The aim of this study was to investigate the safety and analgesic effects of Datura Flos pharmacopuncture (DFP). Methods: The analgesic effects of DFP were assessed using mechanical (hot plate), chemical (formalin test), and thermal (von Frey filament test) pain tests. Forty male Sprague Dawley rats were assigned randomly into DFP (75 mg/kg, 150 mg/kg), lidocaine 0.5%, or normal saline group for treatment on Kl3. Gross pathology, histopathology, biochemistry and hematology were performed. Results: In the hot plate test, DFP at a high dose (HDDFP; 150 mg/kg) produced a significant analgesic effect, at 10 and 20-minutes post injection (p < 0.01). Low dose DFP (LDDFP; 75 mg/kg) also showed an analgesic effect at 10 minutes post injection (p < 0.01). In the formalin test, HDDFP produced an analgesic effect, for 0-10 and 10-20 minutes (p < 0.01) post treatment, whereas LDDFP showed analgesic effects between 10-20 minutes (p < 0.05). In the von Frey filament test, DF-H produced an analgesic effect, 10 (p < 0.01) and 20 minutes post treatment (p < 0.05). LDDFP showed analgesic effect at 10 minutes (p < 0.05). In the acupuncture response test, HDDFP produced an analgesic effect at 10 minutes post treatment (p < 0.05). DF-H did not cause any anatomical changes to the liver or kidney and there were no abnormalities in biochemistry or hematology. Conclusion: DF-H was not toxic and provided short term analgesia, suggesting it may be useful in the management of pain.

Effects of Dual-Coagulant Performance (이중응집이 응집공정에 미치는 영향)

  • Kim, Hee-Geun;Moon, Byung-Hyun;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research is to investigate the effect of the dual coagulant using inorganic coagulants($AICl3{\cdot}6H2O$) and polymer on the coagulant process. Jar-test was conducted by using Kaolin injected raw water. PDA(Photometric Dispersion Analyzer) equipment in order to analyze the size of the particles and the characteristics of the shapes. The change in the rate of sample ores' residual deposited after coagulants were also compared. According to the result derived from this experiment, the concentration of inorganic coagulant reduced 50% and the residual was lower by using dual coagulants compared to using single coagulant. However the dual coagulant required sufficient mixing time, and affected particle characteristics, with the effect of the injection order of coagulants, the simultaneous injection of inorganic coagulant and polymer showed the most effective in the particle removal.

Dermal and Ocular Irritation Studies of Some Phthalates in Rabbits (Phthalate의 피부자극시험 및 안점막자극시험에 관한 연구)

  • 이종권;김주환;이은희;김용규;홍진태;박기숙;안광수;정수연;이선희
    • Toxicological Research
    • /
    • v.17 no.2
    • /
    • pp.91-96
    • /
    • 2001
  • Phthalates are widely used as plasticizers to impart softness and flexibility to normally rigid polyvinylchloride products. However, there are not much studies jar dermal and ocular irritation toxicity of phthalates. So we investigated the skin or eye irritation effect of some phthalates which was not reported. The primary skin irritation of diethyl phthalate (DEP), diisodecyl phthalate (DIDP), diisononyl phthalate (DINP), dipropyl phthalate (DPP) and dipropyl phthalate (DPrP) was studied. The ocular irritation of dibutyl phthalate(DBP), DIDP, DINP, DPP and DPrP was also studied. DEP, DIDP, DINP, DPP, and DPrP were found to be non-irritating to the skin of the test animals. DBP, DIDP, DINP and DPP were found to be non-irritating to the eye of the rabbits. DPrP caused the slight irritations to the eye in 1 or 2 days after treatment but irritation of the animals was soon recovered.

  • PDF