• Title/Summary/Keyword: j factor

Search Result 2,578, Processing Time 0.191 seconds

Reactive Learning Inference System Considering Emotional Factor (감정적 요소를 고려한 반응학습 추론 시스템)

  • 심정연
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1107-1111
    • /
    • 2004
  • As an information technology is developed, more intelligent system considering emotional factor for implementing the personality is required. In this paper, Reactive Learning Inference System considering emotional factor is proposed. Emotional Facter(E) is defined for a criterion for representing the personal preference. This system is designed to have functions of Reactive filtering by Emotional factor, Incremental learning, perception & inference and knowledge retrieval. This system is applied to the area for analysis of customer's tastes and its performance is analyzed and compared.

Evaluation of the J integral of a CT specimen by FEM (FEM에 의한 CT시험편의 J 적분 해석에 관한 연구)

  • Kim, Won Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6440-6445
    • /
    • 2014
  • In steel structures, including ships and offshore structures, defects induced during construction or in use causes cracks and damages. Calculation of the stress intensity factor (SIF) K is one method for crack analysis by fracture mechanics approach. In this paper, an evaluation of K was carried out using the J integral. In particular, in this study, a CT specimen was used to calculate the J integral. In the evaluation, 859 nodes and 1618 elements were used for the J integral calculation of the CT specimen by the in-house FEM program. A comparison of the result with the ASTM formula showed that the results from the current research of the J integral was in the 99% coincidence interval. Overall, cracks in this study can be studied satisfactorily by the J integral from the above mesh size.

An One-factor VaR Model for Stock Portfolio (One-factor 모형을 이용한 주식 포트폴리오 VaR에 관한 연구)

  • Park, Keunhui;Ko, Kwangyee;Beak, Jangsun
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.3
    • /
    • pp.471-481
    • /
    • 2013
  • The current VaR Model based on J. P. Morgan's RiskMetrics has problem that actual loss exceeds VaR under unstable economic conditions because the current VaR Model can't re ect future economic conditions. In general, any corporation's stock price is determined by the rm's idiosyncratic factor as well as the common systematic factor that in uences all stocks in the portfolio. In this study, we propose an One-factor VaR Model for stock portfolio which is decomposed into the common systematic factor and the rm's idiosyncratic factor. We expect that the actual loss will not exceed VaR when the One-factor Model is implemented because the common systematic factor considering the future economic conditions is estimated. Also, we can allocate the stock portfolio to minimize the loss.

Implications of PSR J0737-3039B for the Galactic NS-NS Binary Merger Rate

  • Kim, Chunglee;Perera, Benetge Bhakthi Pranama;McLaughlin, Maura A.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.88.4-89
    • /
    • 2015
  • The Double Pulsar (PSR J0737-3039) is the only neutron star-neutron star (NS-NS) binary in which both NSs have been detectable as radio pulsars. The Double Pulsar has been assumed to dominate the Galactic NS-NS binary merger rate $R_g$ among all known systems, solely based on the properties of the first-born, recycled pulsar (PSR J0737-3039A, or A) with an assumption for the beaming correction factor of 6. In this work, we carefully correct observational biases for the second-born, non-recycled pulsar (PSR J0737-0737B, or B) and estimate the contribution from the Double Pulsar on $R_g$ using constraints available from both A and B. Observational constraints from the B pulsar favour a small beaming correction factor for A (~2), which is consistent with a bipolar model. Considering known NS-NS binaries with the best observational constraints, including both A and B, we obtain $R_g=21_{-14}{^+28}$ per Myr at 95 per cent confidence from our reference model. We expect the detection rate of gravitational waves from NS-NS inspirals for the advanced ground-based gravitational-wave detectors is to be $8_{-5}{^+10}$ per yr at 95 per cent confidence. We discuss prospects of gravitational-wave detection based on our results. Implications of PSR J1906+0746, which is likely to be another tight NS-NS binary in the Galactic disc supported by recent observation, are also remarked.

  • PDF

Wet surface performance test of fin-tube heat exchangers with slit-wavy fin (물결형 슬릿핀이 장착된 핀-관 열교환기의 습표면 성능 실험)

  • Kim, N.H.;Kim, J.S.;Cho, J.P.;Yun, J.H.;Peck, J.H.;Lee, S.G.;Nam, S.B.;Kwon, H.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.153-162
    • /
    • 1997
  • In this study, the wet surface heat transfer coefficients and friction factors of the heat exchanger with slit-wavy fin were measured. Four sample cores of two or three row with fins of 12 fpi or 16 fpi were tested. Tests were conducted in a closed loop wind tunnel, where the heat exchanger was mounted at 45 degree inclination angle. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 420-81. During the course, new definitions of the $\varepsilon$-NTU applicable to enthalpy driving system were introduced. The wet surface heat transfer coefficients were approximately equal to the dry surface values. However, the friction factors were approximately 120% to 170% higher than those of the dry surface. Both the heat transfer coefficient and the friction factor of the wet surface increased as the relative humidity increased, fin pitch decreased, and the number of row decreased, although the difference was not large.

  • PDF

Evaluation by modified offset method on J-R curve with negative crack growth (부균열을 가진 J-R곡선의 수정옾셋방법에 의한 평가)

  • 안광주;최재강
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.45-51
    • /
    • 1997
  • To evaluate the elastic-plastic fracture toughness by this modified offset method, the origin of J-R curve is set with drawing the blunting line on the maximum point of the negative crack growth and R curve is modified by adding the blunting factor of the experimented point on the R curve. The elastic-plastic fracture toughness $J_{IC]$ of A5083-H112 material by the modified offset method we 44kN/m on the smooth CT specimens.

  • PDF

Estimation of Load Characteristic Factor Considering The Load Pattern and Seasonal Characteristic for Consumer (수용가의 형태와 계절별 특성을 고려한 부하특성계수 재 산정)

  • Hwang, H.M.;Jang, S.I.;Kim, K.H.;Kim, J.E.;Rho, D.S.;Jeong, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.450-453
    • /
    • 2003
  • This paper presents the estimation on Load Characteristic Factor(k) which is considered to load pattern and seasonal characteristic of consumer. We can calculate the loss of distribution networks through the equation composing of Load Factor(LF), Loss Load Factor(LLF) and load characteristic factor(k). This equation is similar to the method of Regulator-General Victoria, Australia. Generally, the conventional method for calculating the distribution losses uses k with a constant value from 0.1 to 0.3. However, the k which is a relationship between LF and LLF can be varied by load pattern and seasonal characteristics. It is necessary to estimate the k according to load characteristics. This paper shows the result for recalculating k using the KEPCO's SOMAS data measured in distribution networks.

  • PDF

Identification of Novel SNPs in Bovine Insulin-like Growth Factor Binding Protein-3 (IGFBP3) Gene

  • Kim, J.Y.;Yoon, D.H.;Park, B.L.;Kim, L.H.;Na, K.J.;Choi, J.G.;Cho, C.Y.;Lee, H.K.;Chung, E.R.;Sang, B.C.;Cheong, I.J.;Oh, S.J.;Shin, Hyoung Doo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.1
    • /
    • pp.3-7
    • /
    • 2005
  • The insulin-like growth factors (IGFs), their receptors, and their binding proteins play key roles in regulating cell proliferation and apoptosis. Insulin-like growth factor binding protein-3 (IGFBP3, OMIM #146732) is one of the proteins that bind to the IGFs. IGFBP3 is a modulator of IGF bioactivity, and direct growth inhibitor in the extravascular tissue compartment. We identified twenty-two novel single nucleotide polymorphisms (SNPs) in IGFBP3 gene in Korean cattle (Hanwoo, Bos taurus coreanae) by direct sequencing of full gene including -1,500 bp promoter region. Among the identified SNPs, five common SNPs were screened in 650 Korean cattle; one SNP in promoter (IGFBP3 G-854C), one in 5'UTR region (IGFBP3 G-100A), two in intron 1 (IGFBP3 G+421T, IGFBP3 T+1636A), and one in intron 2 (IGFBP3 C+3863A). The frequencies of each SNP were 0.357 (IGFBP3 G-854C), 0.472 (IGFBP3 G-100A), 0.418 (IGFBP3 G+421T), 0.363 (IGFBP3 T+1636A) and 0.226 (IGFBP3 C+3863A), respectively. Haplotypes and their frequencies were estimated by EM algorithm. Six haplotypes were constructed with five SNPs and linkage disequilibrium coefficients (|D'|) between SNP pairs were also calculated. The information on SNPs and haplotypes in IGFBP3 gene could be useful for genetic studies of this gene.

Characterization of Heterogeneous Interaction Behaviour in Ternary Mixtures by Dielectric Analysis: The H-Bonded Binary Polar Mixture in Non-Polar Solvent

  • Sengwa, R.J.;Madhvi;Sankhla, Sonu;Sharma, Shobha
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.718-724
    • /
    • 2006
  • The heterogeneous association behaviour of various concentration binary mixtures of mono alkyl ethers of ethylene glycol with ethyl alcohol were investigated by dielectric measurement in benzene solutions over the entire concentration range at 25 ${^{\circ}C}$. The values of static dielectric constant $\epsilon_0$ of the mixtures were measured at 1 MHz using a four terminal dielectric liquid test fixture and precision LCR meter. The high frequency limiting dielectric constant $\epsilon_\infty$ values were determined by measurement of refractive index $n_D$ ($\epsilon_\infty\;=\;n_D\;^2$). The measured values of $\epsilon_0$ and $\epsilon_\infty$ were used to evaluate the values of excess dielectric constant $\epsilon^E$, effective Kirkwood correlation factor $g^{eff}$ and corrective correlation factor $g_f$ of the binary polar mixtures to obtain qualitative and quantitative information about the H-bond complex formation. The non-linear behaviour of the observed $\epsilon_0$ values of the polar molecules and their mixtures in benzene solvent confirms the variation in the associated structures with change in polar mixture constituents concentration and also by dilution in non-polar solvents. Appearance of the maximum in $\epsilon^E$ values at different concentration of the polar mixtures suggest the formation of stable adduct complex, which depends on the molecular size of the mono alkyl ethers of ethylene glycol. Further, the observed $\epsilon^E$ < 0 also confirms the heterogeneous H-bond complex formation reduces the effective number of dipoles in these polar binary mixtures. In benzene solutions these polar molecules shows the maximum reduce in effective number of dipoles at 50 percent dilutions. But ethyl alcohol rich binary polar mixtures in benzene solvent show the maximum reduce in effective number of dipoles in benzene rich solutions.

Analysis of Geometrical Effects on Heat Transfer Characteristics in a Modular Flat Tube-Bundle Heat Exchanger (모듈형 편평원관군 열교환기의 열전달 특성 해석)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1014-1021
    • /
    • 2005
  • Flow channels with non-circular cross-sections are encountered in a wide variety of heat exchangers. Accurate friction factor and Colburn j factor data are essential for the design and viable applications of such heat exchangers. In this study, an analysis is con ducted on heat transfer and pressure drop characteristics for tube-bundle heat exchanger with various arrangements of tubes, of which their geometry could easily be modified from a circular one in a harsh environment. The parameters investigated are aspect ratio, pitch, and inclined angle of tubes. The results obtained are: (1) Aspect ratio has larger influence on the j and f factor than pitch; (2) As aspect ratio increases, both j and f factors decrease; (3) The high performance is achieved when the pitch and aspect ratio are in the range of 1.5${\~}$2.5 and 1.25${\~}$2.0, respectively; and (4) the inclined arrangements of tubes show unfavorable results for both heat transfer and pressure drop characteristics in spite of the positive possibility of condensate removals in a latent heat recovery system.