• 제목/요약/키워드: isotope-dilution mass spectrometry

검색결과 80건 처리시간 0.03초

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량 (Quantification of urea in serum by isotope dilution HPLC/MS)

  • 이화심;박상열
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.271-277
    • /
    • 2005
  • 혈액 내 urea는 임상진단 시 신장 기능을 판단하는 중요한 표지물질로서 측정되고 있다. 단백질 등 질소화합물의 최종 대사물인 urea는 콩팥의 사구체에서 걸러져 소변으로 배출되는데, 사구체의 거르는 능력이 저하되면 결국 혈액 속의 urea 농도가 증가하게 되어 신장 기능의 정상여부를 판단할 수 있게 된다. 이러한 임상진단 결과의 신뢰성 향상을 위해서는 측정결과가 일차분석법으로 인증된 인증표준 물질과 소급성 고리를 유지해야 한다. 본 연구에서는 혈청 내 urea의 일차분석법으로서 $15^N_2$-urea를 내부 표준물질로 사용하는 동위원소희석 액체크로마토그라피-질량분석법 (ID-HPLC/MS)을 개발하였다. 이 방법은 측정원리상 고도의 정확성이 확보될 뿐 아니라 별도의 유도체화가 필요 없기 때문에 빠르고 편리하다. $C_{18}$-분리관에 0.1 mmol/L $NH_4Cl$ buffer를 이동상으로 사용하여 urea를 분리하였는데, 이 완충용액은 비교적 분자량이 작은 urea를 질량분석하는데 방해가 크지 않은 장점이 있다. HPLC와 질량분석기의 인터페이스로서 positive mode의 electrospray ionization (ESI)를 사용하여 높은 감도와 재현성을 성취하였다. 국제적으로 인정된 인증표준물질의 분석을 통해 최적화된 방법의 유효성을 확인하였으며, 국제비교시험에도 참여하여 좋은 결과를 얻었다. ISO guide에 따라 불확도를 계산하였으며, 확장 불확도는 95% 신뢰도에서 약 1.8%로 나타났다. 이 분석법은 표준연에서 개발 중인 혈청인증표준물질을 인증하는 일차기준측정절차로도 사용되고 있다.

Burnup Measurement of Spent $U_3$Si/Al Fuel by Chemical Method Using Neodymium Isotope Monitors

  • Kim, Jung-Suk;Jeon, Young-Shin;Park, Kwang-Soon;Song, Byung-Chul;Han, Sun-Ho;Kim, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.375-385
    • /
    • 2001
  • The total burnup in the spent U$_3$Si/Al fuel samples from Hanaro reactor was determined by destructive methods using $^{148}$ Nd, the sum of $^{143}$ Nd and $^{144}$ Nd, the sum of $^{145}$ Nd and $^{146}$ Nd, and the sum of total Nd isotopes($^{143}$ Nd, $^{144}$ Nd, $^{145}$ Nd, $^{146}$ Nd, $^{148}$ Nd and $^{150}$ Nd) monitors. The fractional($^{235}$ U) turnup in the spent fuel samples was also determined by U and Pu mass spectrometric method. The samples were dissolved in a mixture of 4 M HCI and 10 M HNO$_3$ without any catalyst. The separation of U, Pu and Nd from the spiked and unspiked sample solutions was achieved by two sequential anion exchange separation methods. The isotope compositions of these elements, after their separation from the fuel samples were measured by mass spectrometry. The contents of the elements in the spent fuel samples were determined by isotope dilution mass spectrometric method(IDMS) using $^{233}$ U, $^{242}$ Pu and $^{150}$ Nd as spikes. The effective fission yield was calculated from the weighted fission yields averaged over the irradiation period. The difference between total turnup values determined by various Nd monitors were in the range of 1.8%.

  • PDF

동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구 (Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS))

  • 송혜민;김병주;정혁;안성희
    • 분석과학
    • /
    • 제23권6호
    • /
    • pp.524-530
    • /
    • 2010
  • 클로람페니콜은 미생물과 박테리아들의 활동을 억제시킴으로써 동물 치료에 효과적인 축산 항생제 중의 하나이다. 그러나 사람에게 재생 불량성 빈혈과 같은 치명적인 부작용이 발생하여 식용으로 사육하는 동물들에 대한 클로람페니콜의 사용을 유럽을 포함한 많은 나라에서 금지하였다. 본 연구에서는 돼지고기 시료 중 클로람페니콜을 분석하기 위하여 동위원소희석 액체크로마토그래피-질량분석법(IDLC/MS/MS)을 이용하여 정확하고 정밀한 정량분석을 하였다. 돼지고기 시료중의 클로람페니콜은 에틸아세테이트로 추출하였으며, 회수율을 높이기 위하여 고체상 추출법(Solid Phase Extraction)을 이용하였다. 액체크로마토그래피/질량분석기는 전기 분무 이온화 장치(Electrospray Ionization, ESI)를 장착하여 음이 온 모드로 선택반응분석법(Selected Reaction Monitoring mode)에서 수행하였다. 클로람페니콜의 분자이온 $[M-H]^-$이온이 조각이온인 $[M-H-(HCOCl)]^-$로 가는 m/z 321 ${\rightarrow}$ 257와 동위원소의 m/z 326 ${\rightarrow}$ 262 채널을 선택하여 분석하였다. 클로람페니콜을 약 0.2, 1, 10, $25\;{\mu}g$/kg의 농도가 되도록 첨가한 돼지고기 시료로부터 제조값과 측정 분석값을 비교하여 검토한 결과, 측정값들은 불확도 범위 내에서 제조값과 일치함을 보였다. 또한 IRMM(Institute for Reference Materials and Measurement)의 클로람페니콜 분석용 돼지고기 시료인 인증 표준물질 BCR 445를 분석한 결과, 본 실험의 측정값은 불확도 범위 내에서 인증값과 일치함을 보였으며 불확도의 경우에는 IRMM이 제공한 값보다 훨씬 향상된 값을 보였다.

ICP-MS에 의한 생체시료 중의 극미량 금속오염도 측정 (Determination of Trace Metals in Biological Samples by Inductively Coupled Plasma Mass Spectrometry)

  • 박창준;이상호;정구순;이광우
    • 대한화학회지
    • /
    • 제37권9호
    • /
    • pp.800-805
    • /
    • 1993
  • 정도관리용 생체기준물질 중의 극미량원소에 대한 분석법을 확립하였다. 생체시료를 질산-과산화수소 혼합산화제와 함께 테플론 가압분해용기에 넣어 마이크로파 오븐에서 분해하는 시료전처리법(microwave digestion)을 사용하였다. 시료를 분해시키기 전에 정량할 극미량금속의 안정 동위원소를 첨가하여 동위원소희석 질량분석법을 적용하였다. 혈액과 소나무잎 기준물질에 이러한 분석방법을 적용하여 기준값과 일치되는 결과를 얻었다.

  • PDF

Quantification of $Cu(In_xGa_{1-x})Se_2$ Solar Cell by SIMS

  • Jang, Jong-Shik;Hwang, Hye-Hyen;Kang, Hee-Jae;Min, Hyung-Sik;Han, Myung-Sub;Suh, Jung-Ki;Cho, Kyung-Haeng;Chung, Yong-Duck;Kim, Je-Ha;Kim, Kyung-Joong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.275-275
    • /
    • 2012
  • The relative composition of $Cu(InGa)Se_2$ solar cells is one of the most important measurement issues. However, quantitative analysis of multi-component alloy films is difficult by surface analysis methods due to severe matrix effect. In this study, quantitative depth profiling analysis of CIGS films was investigated by secondary ion mass spectrometry (SIMS). The compositions were measured by SIMS using the alloy reference relative sensitivity factors derived from the certified compositions and the total counting numbers of each element. The compositions measured by SIMS were linearly proportional to those by inductively coupled plasma-mass spectrometry (ICP-MS) using isotope dilution method. In this study, the quantification measured by ICP-MS method is compared with the composition calculated by SIMS depth profiles with AR-RSFs obtained from the reference. The SIMS depth profile of CIGS thin films according to the manufacturing condition was converted into compositional depth profile.

  • PDF

화학적 방법에 의한 핵연료의 연소도 측정 (Burnup Measurement of Irradiated Uranium Dioxide Fuel by Chemical Methods)

  • Kim, Jung-Suk;Han, Sun-Ho;Suh, Moo-Yul;Joe, Kih-Soo;Eom, Tae-Yoon
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.277-286
    • /
    • 1989
  • PWR 핵연료의 연소도측정은 삼중스파이크(U-233. Pu-242, Nd-150)를 사용한 동위원소 희석 질량분석법으로 U, PU, Nd-148 및 Nd-(145+146)을 정량하여 수행하였다. 이 방법은 먼저 두개의 연속적 이온교환수지 분리과정을 거친다. Pu는 첫번째 음이온 교환수지 분리관(Dowex AG 1 X 8)으로부터 12 M HCl-0.1 M HI 혼합용액으로 분리하고 이어서 0.1 M HCl로 U을 분리하였다. Nd은 질산-메탄올 용리액으로 두번째 음이온 교환수지분리관(Dowex AG 1 X 4) 상에서 분리하였다. 각 부분을 열이온화질량분석법으로 각각의 동위원소비를 측정하였다. Nd-148과 Nd-(145+146) 방법 사이의 차이는 평균 2.07%로 나타났다. 이 결과를 U과 Pu동위원소를 이용한 무거운 원소방법 및 Cs-137의 파괴 감마분광측정법과 비교하였다. 연소도에 대한 U과 Pu의 동위원소 조성의존도와 동위원소사이의 상관관계를 그래프로서 설명하였다.

  • PDF

동위원소희석 ICP-MS분석법에 의한 남극 세종기지 주변 토양의 중금속 측정 (Measurement of heavy metals in antarctic soil at the king sejong station: application of isotope dilution inductively coupled plasma mass spectrometry)

  • 서정기;황의진;민형식
    • 분석과학
    • /
    • 제21권5호
    • /
    • pp.364-374
    • /
    • 2008
  • 2000년도에 COMNAP/SCAR에 의해 극지지역의 환경모니터링에 관한 표준기술지침서인 'Antarctic Environmental Monitoring Handbook'이 발간되었다. 이 지침서에 따라 남극세종기지주변지역의 토양시료중의 중금속을 분석하였다. 시료분해방법은 고압산분해 방법을 사용하였고, 분석방법으로는 동위원소희석 유도결합플라스마질량분석법을 사용하여 토양중의 Pb, Cu, Zn 성분을 분석하였다. 분석방법의 정확성을 확인하기 위해 표준시료인 NIST 2702를 분석한 결과 인증값의 99.5~100.8% 범위내에서 일치하였다. Chelex 100 이온교환수지를 사용하여 간섭이온을 제거하기 위해 매질을 분리하였다. 측정결과 인위적오염이 예상되는 기지주변지역의 중금속의 평균농도는 각각 Pb 332.9 mg/kg, Cu 95.6 mg/kg, Zn 115.3 mg/kg로 나타났으며, 기지에서 멀리 떨어진 지역의 평균농도는 각각 Pb 28.1 mg/kg, Cu 101.8 mg/kg, Zn 115.6 mg/kg로 나타났다. Pb 농도는 기지주변지역과 멀리 떨어진 지점에서 현저한 차이를 보였다.

동위원소희석 액체크로마토그래피 질량분석법에 의한 분유 내 콜레스테롤의 정량 (Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry)

  • 안은정;이화심;김병주;이계호
    • 분석과학
    • /
    • 제28권6호
    • /
    • pp.460-466
    • /
    • 2015
  • 분유 내 콜레스테롤을 정량분석하기 위한 일차분석법으로 동위원소희석 질량분석법을 개발하였다. 내부표준물질로 콜레스테롤-d4를 사용하여 분유에 첨가하였다. 분유에 지방산과 에스테르형태로 결합되어 있는 콜레스테롤을 자유 콜레스테롤로 바꾸어주기 위해 비누화과정을 수행하였다. 비누화과정은 반응온도, 반응시간, 사용한 KOH의 농도에 따라서 최적화하였으며, 그 결과로 분유시료 0.1 g에 대해 70 ℃에서 180 분 동안 8 M의 KOH 0.8 mL를 첨가하여 반응을 진행시키는 최적화조건을 확립하였다. 이와 같은 조건으로 실험을 진행하여 재현성은 0.23%, 확장불확도는 95%의 신뢰범위에서 1.9%로 추정되었다. 확립된 동위원소희석 질량분석법의 유효화를 위해 분유내에서 콜레스테롤의 인증값을 가지는 NIST SRM을 측정하였고 이 결과가 인증값과 불확도 범위내에서 일치하는 것을 확인하였다.

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.