• Title/Summary/Keyword: isotope ratio.

Search Result 254, Processing Time 0.023 seconds

Effects of salmon carcass on forest and stream ecosystems, in Hokkaido, Japan -evidence by stable isotope analysis-

  • Yanai, Seiji;Kochi, Kaori
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.198-203
    • /
    • 2003
  • The effects of salmon carcasses on forest and stream ecosystems were determined by nitrogen stable isotope analysis in natural streams in Hokkaido, Northern Japan, where numerous chum salmon (Oncoryhncus keta) were migrated upstream ITom ocean to spawn in autumn. The leaves and soils surrounding riparian forest and stream dwelling invertebrates were collected before and after migration. The nitrogen stable isotope ratio $({\delta}^{15}N)$ of riparian vegetation (Salix spp.) were different depending on the presence of salmon and distance from the stream. The $({\delta}^{15}N)$ of stream dwelling invertebrates were different between salmon present and absent stream. This difference was tested using the experiment channel by implanting salmon carcasses. The nitrogen stable isotope ratio of epilithic algae and leaf shredding animals were nearly 3 higher in the salmon implanted treatment suggesting that around 20% of salmon derived nitrogen was uptake either in algae and leaf shredding invertebrates. These results suggest that the salmon carcasses effects not only on stream primary production but also on primary consumers, which decompose leaves fertilized with nitrogen from carcasses.

  • PDF

Hydrogen Isotope Separation by using Zeolitic lmidazolate Frameworks (ZIF-11) (ZIF-11을 이용한 수소 동위원소 분리)

  • Lee, Seulji;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.655-659
    • /
    • 2020
  • Hydrogen isotopes (i.e. deuterium and tritium) are supplied to the tokamak in the International Thermonuclear Experimental Reactor (ITER) fuel cycle. One important part of the ITER fuel cycle is the recycling of unused fuel back to the tokamak, as almost 99 % of fuel is unburned during fusion reaction. For this, cryogenic distillation has been used in the isotope separation system (ISS) of ITER, but this technique tends to be energy-intensive and to have low selectivity (typically below 1.5 at 24 K). Recently, efficient isotope separation by porous materials has been reported in the so-called quantum sieving process. Hence, in this study, hydrogen isotope adsorption behavior is studied using chemically stable ZIF-11. At low temperature (40 K ~ 70 K), the adsorption increases and the sorption hysteresis becomes stronger as the temperature increases to 70K. Molar ratio of deuterium to hydrogen based on the isotherms shows the highest (max. 14) ratio at 50 K, confirming the possibility of use as a potential isotope separation material.

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

Technical Procedure for Identifying the Source of Nitrate in Water using Nitrogen and Oxygen Stable Isotope Ratios (질소 및 산소 안정동위원소 활용 수계 질산성 질소 오염원 판별을 위한 기술 절차 제안)

  • Kim, Kibeum;Chung, Jaeshik;Lee, Seunghak
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.87-98
    • /
    • 2022
  • This study aims to prepare a technical protocol for identifying the source of nitrate in water using nitrogen (δ15N) and oxygen (δ18O) stable isotope ratios. The technical processes for nitrate sources identification are composed of site investigation, sample collection and analysis, isotope analysis, source identification using isotope characteristics, and source apportionment for multiple potential sources with the Bayesian isotope mixing model. Characteristics of various nitrate potential sources are reviewed, and their typical ranges of δ15N and δ18O are comparatively analyzed and summarized. This study also summarizes the current knowledge on the dual-isotope approach and how to correlate the field-relevant information such as land use and hydrochemical data to the nitrate source identification.

Source Tracking of Particular Matters using Stable Isotope Analysis and Water Quality Characteristics in Gulpo and Anyang Stream, Han-River (한강수계 굴포천과 안양천에서 안정동위원소와 수질 특성을 이용한 입자성 물질의 기원 추적)

  • Hong, Jung-Ki;Im, Jong Kwon;Son, Ju Yeon;Noh, Hye-Ran;Yu, Soon-Ju;Lee, Bo-Mi
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.116-124
    • /
    • 2020
  • This study aims to identify the characteristics of organic matter and pollutant sources using water quality and stable isotope ratios (δ15N, δ13C) of the two inflow tributaries (Gulpo (GP) and Anyang (AY) streams). Water samples were analyzed in June and September 2018, and the results showed that the concentrations of nutrients, such as TN and NO3-N, were increased at GP4, which is located at the downstream of sewage treatment facilities(STFs). TOC and TN ratios showed a strong positive correlation (R2 = 0.77, p<0.01) at all points except for GP4. The results of GP's stable isotope ratio analysis do not appear to be a constant cluster compared to AY because GPs with large amounts of pollutants from the industry (metal processing companies, etc.) have less tributary, shorter waterway and significantly different external sources. This could be attributed to different sources of external inflow despite its smaller number of tributaries and shorter waterways than AY. In the first half of the year, the δ155N of GP4 was affected by discharge of STFs, while AY3 seemed to have an influence of tributary than the discharge of STFs. Consequently, using water quality, stable isotope ratio and C/N, the sources of contamination in two streams with different contaminants were identified and origin was estimated.

Provenance Study on Lead Isotope of the Bronze Using a Korea Peninsula Lead Isotope Data - Focused on Bronze Relics Excavated from Cheonghaejin - (한반도 납광산의 납동위원소비를 이용한 청동 원료의 산지추정 - 청해진 출토 청동기를 중심으로 -)

  • Hwang, Jin Ju;Kim, So Jin;Han, Woo Rim;Han, Min Su
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.263-270
    • /
    • 2014
  • This paper was researched that provenance of the raw material for bronze relics excavated Cheonghaejin using the distribution of lead isotope ratio based on galena ores of South Korea. Also we want to make sure that the trace elements appearing as a by-product can be used as a secondary indicator for provenance research. In the case of the galena map of the East-North Asia (Mabuchi, 1985), data are plotted in China area. Therefore it is estimated that most bronzes were produced with lead ore from China. On the other hand, the same data are plotted in the Okcheon Metamorphic Belt and Yeongnam Massif of the galena map of South Korea (KOPLID, 2012). Also the contents of Ag and Sb are available as indicator due to separate ores from similar zone in lead isotope ratio.

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

C/N/O/S stable isotopic and chemometric analyses for determining the geographical origin of Panax ginseng cultivated in Korea

  • Chung, Ill-Min;Kim, Jae-Kwang;Lee, Ji-Hee;An, Min-Jeong;Lee, Kyoung-Jin;Park, Sung-Kyu;Kim, Jang-Uk;Kim, Mi-Jung;Kim, Seung-Hyun
    • Journal of Ginseng Research
    • /
    • v.42 no.4
    • /
    • pp.485-495
    • /
    • 2018
  • Background: The geographical origin of Panax ginseng Meyer, a valuable medicinal plant, is important to both ginseng producers and consumers in the context of economic profit and human health benefits. We, therefore, aimed to discriminate between the cultivation regions of ginseng using the stable isotope ratios of C, N, O, and S, which are abundant bioelements in living organisms. Methods: Six Korean ginseng cultivars (3-yr-old roots) were collected from five different regions in Korea. The C, N, O, and S stable isotope ratios in ginseng roots were measured by isotope ratio mass spectrometry, and then these isotope ratio profiles were statistically analyzed using chemometrics. Results: The various isotope ratios found in P. ginseng roots were significantly influenced by region, cultivar, and the interactions between these two factors ($p{\leq}0.001$). The variation in ${\delta}^{15}N$ and ${\delta}^{13}C$ in ginseng roots was significant for discriminating between different ginseng cultivation regions, and ${\delta}^{18}O$ and ${\delta}^{34}S$ were also affected by both altitude and proximity to coastal areas. Chemometric model results tested in this study provided discrimination between the majority of different cultivation regions. Based on the external validation, this chemometric model also showed good model performance ($R^2=0.853$ and $Q^2=0.738$). Conclusion: Our case study elucidates the variation of C, N, O, and S stable isotope ratios in ginseng root depending on cultivation region. Hence, the analysis of stable isotope ratios is a suitable tool for discrimination between the regional origins of ginseng samples from Korea, with potential application to other countries.

Discrimination of the Origin of Ephedrine and Pseudoephedrine for Pharmaceutical Powder Materials by Carbon and Nitrogen Stable Isotope Ratio Analysis ($^{13}C$$^{15}N$ 안정성 동위원소 비율 분석에 의한 원료의약품에서 에페드린 및 슈도에페드린의 기원 판별)

  • Baeck, Seung-Kyung;Jang, Moon-Hee;Makino, Yukiko;Jeong, Jin-Il;Yang, Won-Kyang;Choi, Hwa-Kyung;Chung, Hee-Sun;Pyo, Myung-Yun;Nagano, Tetsuo
    • YAKHAK HOEJI
    • /
    • v.53 no.5
    • /
    • pp.293-297
    • /
    • 2009
  • The abuse of methamphetamine (MA) is one of the most serious drug abuses in Asia. And, the prevention of precursor production for abuse drug is one of the most effective drug control system. Isotope ratio analysis at natural abundance levels have been used to establish the environmental source or the geographic origin of various biological and nonbiological materials. Ephedrine, the precursor of MA, is produced by one of three methods; extraction from Ephedra plants, full chemical synthesis or via a semi-synthetic process involving the fermentation of sugar, followed by amination. We investigated the origin of ephedrine and pseudoephedrine based on the carbon and nitrogen values for nineteen pharmaceutical powder materials (PPMs) obtained from pharmaceutical company in Korea by stable isotope ratio mass spectrometry coupled to an elemental analyser (EA-IRMS). The carbon delta values for the ephedrine and pseudoephedrine were -24.21~-22.72 (mean=-23.72) $^{\cir}/_{\circ\circ}$ and -23.79~-22.71 (mean=-23.48) $^{\cir}/_{\circ\circ}$. The nitrogen delta values were 3.51~5.55 (4.43) $^{\cir}/_{\circ\circ}$ and 2.24~8.22 (5.42) $^{\cir}/_{\circ\circ}$. These results indicate that PPMs are semi-synthetic products. Therefore the origins of ephedrine(natural, semi-synthetic or synthetic) could be discriminated by using carbon and nitrogen stable isotope ratios. we are sure tat this stable isotope ratio analysis can discriminate the origins of precursors of methamphetamine.

Lead Isotope Ratio Data Base for Metal Objects at the National Museum of Korea (I) (국립중앙박물관소장 금속유물의 납동위원소비 데이터베이스 구축(I))

  • Kang, Hyungtae;Ahn, Juyoung;Huh, Ilkwon
    • Conservation Science in Museum
    • /
    • v.8
    • /
    • pp.81-95
    • /
    • 2007
  • The Conservation Science Team of National Museum of Korea has established the data base of lead isotope ratio as the scientific research of bronze patina, which was acquired from conservation process of metal objects, and based on this result, it intends to conduct the research related to the production places of raw material for the bronze objects. As the equipment for analysis of lead isotope ratio of the bronze patina, the thermal ionization mass spectrometer (TIMS) was used. As part of the research, in 2007, the 11 samples of the bronze Patina from the objects, believed to belong to of Nangnang(Lelang), the 6 items of bronze patina from the flower-shaped bronze dishes, belong to Unified Silla period and 4 items from the Goryeo bronze bell were acquired and analyzed the lead isotope ratio. Based on the data of the lead isotope ratio from the galena of Korea, China and Japan, the provenance raw materials were estimated through the comparison of their lead isotope ratios. In the future, the Conservation Science Team of the National Museum of Korea will collect as much bronze patina as possible from the process of conservation treatment of metal objects, and analyze them in order to conduct the study of provenance with the type, period and the region of the objects.