• 제목/요약/키워드: isolation system

검색결과 1,778건 처리시간 0.033초

지진 격리된 교량의 내진성능에 대한 실험적 연구 (Experimental Study on Seismic Performance of Base-Isolated Bridge)

  • Chung, Woo-Jung;Yun, Chung-Bang;Kim, Nam-Sik;Seo, Ju-Won
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.144-153
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrates that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation system using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminated rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

C형 강재 지진격리장치의 성능시험 (Performance Test of C-shape Steel Base Isolation System)

  • 정대유;심철환;박형기
    • 한국지진공학회논문집
    • /
    • 제13권4호
    • /
    • pp.25-35
    • /
    • 2009
  • 기존의 교량받침으로 많이 사용되고 있는 폴리우레탄 디스크를 적용한 POT형식에 C형 강재감쇠장치를 추가적으로 적용한 새로운 형태의 지진격리장치에 대한 명확한 정적 성능검증과 동적특성을 파악하기 위하여 최대 극한 수직하중 시험, 최대 회전 시험, 동적재하 시험 및 동적재하 극한 반복시험을 시행하였다. 해석적 결과와 성능시험 결과를 비교분석한 결과, 충분한 감쇠능력을 보유하고있을 뿐만 아니라, 설계기준에도 적합하다는 결론을 얻을 수 있었다. 또한, EDC 및 유효강성값의 시험치가 이론치와 유사하여 시험 결과값의 분석이 유효함을 보였다.

다목적 유전자알고리즘을 이용한 첨단기술산업 시설물의 스마트 미진동제어 (Smart Microvibration Control of High-Tech Industry Facilities using Multi-Objective Genetic Algorithm)

  • 김현수;강주원;김영식
    • 한국공간구조학회논문집
    • /
    • 제13권2호
    • /
    • pp.37-45
    • /
    • 2013
  • Reduction of microvibration is regarded as important in high-technology facilities with high precision equipments. In this paper, smart control technology is used to improve the microvibration control performance. Mr damper is used to make a smart base isolation system amd fuzzy logic control algorithm is employed to appropriately control the MR damper. In order to develop optimal fuzzy control algorithm, a multi-objective genetic algorithm is used in this study. As an excitation, a train-induced ground acceleration is used for time history analysis and three-story example building structure is employed. Microvibration control performance of passive and smart base isolation systems have been investigated in this study. Numerical simulation results show that the multi-objective genetic algorithm can provide optimal fuzzy logic controllers for smart base isolation system and the smart control system can effectively reduce microvibration of a high-technology facility subjected to train-induced excitation.

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

고성능 전자장을 갖는 수처리 시스템의 개발 (Development of the Water Treatment System with High Performance Electromagnetic Field)

  • 이용근
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.155-159
    • /
    • 2005
  • This paper presents the water treatment system with high performance electromagnetic field for a good quality of water. The electromagnetic field water treater consists of a solion, a solion body, and a high voltage converter. The high voltage converter is controlled by PWM current controller. The high voltage converter of 13W is designed for an isolation operation amp, an isolation current detector, and an over current protector. Using the high voltage PWM converter, the system with the proposed electromagnetic field water treater can be controlled easily. Simulation and experimental results show the effectiveness of the system strategy proposed for the scale rejection.

공기스프링과 압전작동기를 결합한 복합형 미진동 방진마운트 시스템 개발 (Development of a Hybrid Mount System Combined Airspring with Piezostack Actuator for Microvibration)

  • 문석준;정형조;신윤호;장동두;정종안;문영종
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.56-65
    • /
    • 2011
  • A new hybrid mount system is proposed for microvibration control in a high-tech factory. The mount consists of an airspring as a passive device and a piezostack actuator as an active device. The two devices are connected in series. Some numerical simulations and experimental tests are carried out to evaluate isolation performance of the mount system comprising of four proposed hybrid mounts. As a control logic, the specific algorithm is adopted for considering multiple target frequencies of excitation based on a Filtered-X LMS algorithm. The results are compared with isolation performance of the passive airspring mount system. It is confirmed that the proposed hybrid mount system has great performance on microvibration.

전자빔건 헤드유니트의 설계와 제작 (Establishment of Gun Head Unit for Electron Beam Machining System)

  • 강재훈;이찬홍;최종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1875-1878
    • /
    • 2005
  • It is not efficient and scarcely out of the question to use commercial expensive electron beam lithography system widely used for semiconductor fabrication process for the manufacturing application field of various devices in the small business scope. Then scanning electron microscope based electron beam machining system is maybe regarded as a powerful model can be used for it simply. To get a complete suite of thus proper system, column unit build up with electron beam gun head unit is necessarily required more than anything else to modify scanning electron microscope. In this study, various components included ceramic isolation plate and main body which are essentially constructed for electron beam gun head unit are designed and manufactured. And this electron beam gun head unit will be used for next connected study in the development step of scanning electron microscope based electron beam machining system.

  • PDF

Model-based fault diagnosis methodology using neural network and its application

  • Lee, In-Soo;Kim, Kwang-Tae;Cho, Won-Chul;Kim, Jung-Teak;Kim, Kyung-Youn;Lee, Yoon-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.1-127
    • /
    • 2001
  • In this paper we propose an input/output model based fault diagnosis method to detect and isolate single faults in the robot arm control system. The proposed algorithm is functionally composed of three main parts-parameter estimation, fault detection, and isolation, When a change in the system occurs, the errors between the system output and the estimated output cross a predetermined threshold, and once a fault in the system is detected, and in this zone the estimated parameters are transferred to the fault classifier by ART2(adaptive resonance theory 2) neural network for fault isolation. Since ART2 neural network is an unsupervised neural network fault classifier does not require the knowledge of all possible faults to isolate the faults occurred in the system. Simulations are carried out to evaluate the performance of the proposed ...

  • PDF

적응성 간섭잡음제거기를 이용한 동일 주파수 중계기 (On-Frequency Repeater using Interference Cancellation System)

  • 김선진;이제영;이종철;김종헌;이병제;김남영
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.177-181
    • /
    • 2002
  • In this paper, the cancellation or suppression of the feedback interference from Tx antenna using the same frequency is studied. The major problems on the wireless communication system using the same frequency or on-frequency repeater (OFR) are the coupling and isolation between Rx and Tx antenna. In order to increase the isolation between Rx and Tx antenna and to Prevent the self-oscillation of the receiver system, this paper is verified the possibility of the application of interference cancellation system and proposed the design method of the OFR using interference cancellation system.

  • PDF

EVALUATION OF PLANT OPERATIONAL STATES WITH THE CONSIDERATION OF LOOP STRUCTURES UNDER ACCIDENT CONDITIONS

  • MATSUOKA, TAKESHI
    • Nuclear Engineering and Technology
    • /
    • 제47권2호
    • /
    • pp.157-164
    • /
    • 2015
  • Nuclear power plants have logical loop structures in their system configuration. This paper explains the method to solve a loop structure in reliability analysis. As examples of loop structured systems, the reactor core isolation cooling system and high-pressure core injection system of a boiling water reactor are considered and analyzed under a station blackout accident condition. The analysis results show the important role of loop structures under severe accidents. For the evaluation of the safety of nuclear power plants, it is necessary to accurately evaluate a loop structure's reliability.