• Title/Summary/Keyword: isolation system

Search Result 1,775, Processing Time 0.024 seconds

A Study on a grounding system of electric railway (전기철도 접지시스템에 대한 연구)

  • Lee, Ho-Jong;Shin, Myoung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1482-1504
    • /
    • 2007
  • An electrical railway system uses high voltage system for train traction and low voltage system for train control. Railway systems are broadly distributed across mountains, sea sides and cities. Electrical accidents provoke the death and injury of a human being and the damage of the equipment by the overcurrent due to the catenary dropping and by the overvoltage due to lightning. Grounding systems are adopted for the protections of the system from the overcurrent and the overvoltage. Isolation grounding for each system can be easily installed. However, the closed circuits between grounding systems can be occurred. The currents flow through the closed circuits cause the abnormal operation of the system. To overcome the problem of the isolation grounding, the equipotential bonding is usually adopted. The equipotential bonding should have very small grounding resistance. In this paper, we showed the transition from the isolation grounding system to the common grounding system and presented the comparison and the analysis of two grounding systems by simulation. In addition, we proposed the direction for a new grounding system of electric railway.

  • PDF

A Study on the Improvement of MIMO Antenna Isolation for Mobile Applications (휴대 단말기용 MIMO 안테나의 격리도 향상에 관한 연구)

  • Yoon, In-Seop;Yan, Xiao-Jia;Kim, Sang-Uk;Jo, Yun-Hyun;Park, Hyo-Dal
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.9
    • /
    • pp.987-992
    • /
    • 2015
  • In this paper, neutralization line structure have been employed to improve the isolation between the MIMO antenna system. The proposed MIMO antenna size is $116mm{\times}64mm{\times}5mm$ and designed on FR-4(${\varepsilon}r=4.4$) ground substrate. Neutralization line was applied to enhance isolation between the each antenna elements. The fabricated antenna satisfied a VSWR below 3 in LTE band B13 and the isolation between the MIMO antenna system is presented below -15dB. On the H-plane, antenna shows an omnidirectional pattern. In LTE band B13, the antenna presents a gain of a -2.6dBi ~-1.18dBi and radiation efficiency of 33.49% ~ 46.45%. Comparing measurement result with the outcome of simulation, the proposed MIMO antenna is expected to be applied for mobile application.

National Level Response to Pandemic (H1N1) 2009 (정부의 신종인플루엔자 A(H1N1) 대응)

  • Lee, Dong-Han;Shin, Sang-Sook;Jun, Byung-Yool;Lee, Jong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The World Health Organization (WHO) announced the emergence of a novel influenza on April 24, 2009, and they declared pandemic on June 11. In Korea, the proportion of influenza-like illness and the consumption of antiviral agents peaked in early November. The government established the Central Headquarters for Influenza Control and operated the emergency response system. In the quarantine stations, we checked the body temperature and collected quarantine questionnaires from all the arrivals from infected countries. We also isolated the confirmed cases in the national isolation hospitals. However, as the community outbreaks were reported, we changed strategy from containment to mitigation. We changed the antiviral agent prescription guideline so that doctors could prescribe antiviral agents to all patients with acute febrile respiratory illness, without a laboratory diagnosis. Also the 470 designated hospitals were activated to enhance the efficacy of treatment. We vaccinated about 12 million people and manage the adverse event following the immunization management system. In 2010, we will establish additional national isolation wards and support hospitals to establish fever clinics and isolation intensive care unit (ICU) beds. We will also make a computer program for managing the national isolation hospitals and designated hospitals. We will establish isolation rooms and expand the laboratory in quarantine stations and we will construct a bio-safety level 3 laboratory in each province. In addition, we plan to construct a bio-safety level 4 laboratory at a new Korea Centers for Disease Control and Prevention (KCDC) facilities in Ossong.

The effect of composite-elastomer isolation system on the seismic response of liquid-storage tanks: Part I

  • Shahrjerdi, A.;Bayat, M.
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.513-528
    • /
    • 2018
  • A typical viable technique to decrease the seismic response of liquid storage tanks is to isolate them at the base. Base-isolation systems are an efficient and feasible solution to reduce the vulnerability of structures in high seismic risk zones. Nevertheless, when liquid storage tanks are under long-period shaking, the base-isolation systems could have different impacts. These kinds of earthquakes can damage the tanks readily. Hence, the seismic behaviour and vibration of cylindrical liquid storage tanks, subjected to earthquakes, is of paramount importance, and it is investigated in this paper. The Finite Element Method is used to evaluate seismic response in addition to the reduction of excessive liquid sloshing in the tank when subjected to the long-period ground motion. The non-linear stress-strain behaviour pertaining to polymers and rubbers is implemented while non-linear contact elements are employed to describe the 3-D surface-to-surface contact. Therefore, Nonlinear Procedures are used to investigate the fluid-structure interactions (FSI) between liquid and the tank wall while there is incompressible liquid. Part I, examines the effect of the flexibility of the isolation system and the tank aspect ratio (height to radius) on the tank wall radial displacements of the tank wall and the liquid sloshing heights. Maximum stress and base shear force for various aspect ratios and different base-isolators, which are subjected to three seismic conditions, will be discussed in Part II. It is shown that the composite-base isolator is much more effective than other isolators due to its high flexibility and strength combined. Moreover, the base isolators may decrease the maximum level pertaining to radial displacement.

Assessing the effect of inherent nonlinearities in the analysis and design of a low-rise base isolated steel building

  • Varnavaa, Varnavas;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.5 no.5
    • /
    • pp.499-526
    • /
    • 2013
  • Seismic isolation is an effective method for the protection of buildings and their contents during strong earthquakes. This research work aims to assess the appropriateness of the linear and nonlinear models that can be used in the analysis of typical low-rise base isolated steel buildings, taking into account the inherent nonlinearities of the isolation system as well as the potential nonlinearities of the superstructure in case of strong ground motions. The accuracy of the linearization of the isolator properties according to Eurocode 8 is evaluated comparatively with the corresponding response that can be obtained through the nonlinear hysteretic Bouc-Wen constitutive model. The suitability of the linearized model in the determination of the size of the required seismic gap is assessed, under various earthquake intensities, considering relevant methods that are provided by building codes. Furthermore, the validity of the common assumption of elastic behavior for the superstructure is explored and the alteration of the structural response due to the inelastic deformations of the superstructure as a consequence of potential collision to the restraining moat wall is studied. The usage of a nonlinear model for the isolation system is found to be necessary in order to achieve a sufficiently accurate assessment of the structural response and a reliable estimation of the required width of the provided seismic gap. Moreover, the simulations reveal that the superstructure's inelasticity should be taken into account, especially if the response of the structure under high magnitude earthquakes is investigated. The consideration of the inelasticity of the superstructure is also recommended in studies of structural collision of seismically isolated structures to the surrounding moat wall, since it affects the response.

Microvibration Control of High Technology Facilities Subjected to Train-induced Excitation using Smart Base Isolation (열차진동하중을 받는 첨단시설물의 스마트 면진시스템을 이용한 미진동제어)

  • Kim, Hyun-Su;Kang, Joo-Won;Kim, Young-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.99-108
    • /
    • 2012
  • Microvibration problem of high-technology facilities, such as semi-conductor plants and TFT-LCD plants, has been considered as important factors that affects the performance of products and thus it is regarded as important in facilities with high precision equipments. In this paper, various base isolation control systems are used to investigate their microvibration control performance. To this end, train-induced ground acceleration is used for time history analysis and three-story example building structure is employed. Microvibration control performance of passive and smart base isolation systems have been investigated in this study. Based on numerical simulation results, it has been verified that smart base isolation system can control microvibration of a high-technology facility subjected to train-induced excitation.

A Study on the Facility Eligibility Inspection & Effect of Environment Improvement for National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 및 환경개선효과 분석에 관한 연구)

  • Lee, Du Ru Na;Kwon, Soon Jung;Sung, Min Ki;Yoon, Hyung Jin;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.67-75
    • /
    • 2017
  • Purpose: This study is for the facility eligibility and improvement evaluation analysis for the patient care environment of 7 facilities which has national inpatient isolation units. Methods: For the evaluation, first of all, the patient care environment of national inpatient isolation units are scrutinized by the checklist which is used on from 2014 with the 4 fields of criteria : architectural planning and layout, general requirement and condition for operating the negative pressured isolated patient room, HVAC system, and waste water discharging system. Finally, the evaluation results are compared with that of 2014. Results: The result shows that the average value of facility eligibility is 89.3 percent and which is 8.9 percent higher than the value before the MERS occurred. Implications: It is clear that facility remodeling of 7 institutions is being performed continuously, and the result of facility eligibility evaluation is reflected on design of a new 21 national inpatient isolation units those are going to be constructed from 2016. Therefore, it is expected that this study is used as a practical reference to establish the criteria of patient care environment management and safety management for both infectious disease outbreak and general service condition.

Seismic Performance Evaluation for Piloti Structures of MPS Seismic Isolation Device in Response to Earthquakes on the Richter Scale 7.0 - Nonlinear Dynamic Analysis (리히터 규모 7.0의 지진에 대응하는 MPS 면진받침의 필로티 구조물에 대한 내진성능 평가 - 비선형 동적 해석)

  • Cho, Han-Min;Hu, Jong-Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.13-20
    • /
    • 2021
  • Recently, various piloti structures have been constructed in Korea to secure residential and parking spaces. However, these piloti structures have been constructed in the form of protruding columns without walls to secure parking spaces on the first floor. In this form, when an earthquake occurs, the column is relatively easily damaged compared to general structures, and such damage can lead to the collapse of the structure. Therefore, in this study, a study on securing the safety of the piloti structure using the MPS (Multi Performance System) seismic isolation device was conducted. Nonlinear dynamic analysis according to the presence or absence of MPS seismic isolation device was performed on the existing piloti structure, and analysis results were compared and analyzed. Finally, each seismic performance evaluation was performed and the superiority of the MPS seismic isolation device was verified.

Concept Design of Vibration Isolation System for Development of Optical Payload of Satellite (위성광학탑재체 개발을 위한 나노급 방진장치 개념 설계)

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Kim, Young-Key;Moon, Guee-Won;Moon, Sang-Moo;Kim, Hong-Bea
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.949-952
    • /
    • 2005
  • According to the national space program in Korea, is satellites will be launch into space up to 2015. Especially, KARI is going to develope of its own a high resolution camera of less than 1m to be mounted on next Multipurpose Satellite. When performing testing of large spacecraft or hardware that will be launched into orbit, it is necessary to conduct a testing with space-simulated environment. To achieve this requirement, thermal vacuum chamber is generally used. KARI has been developed a very Large Thermal Vacuum Chamber(LTVC) from 2003 to accomodate future space program, such as KOMPSAT, COMS, and Launch vehicles. This new facility will be used to qualify the first self developed High Resolution Camera, which will be loaded on KOMPSAT-3. To perform an optical test for space camera, it is necessary to provide vibration free environment. Thus the vibration responses on the optical table due to external vibration should be minimized by using a special isolation system. In this paper, we propose the concept design of vibration isolation system for the development of the high resolution camera.

  • PDF

Base isolated RC building - performance evaluation and numerical model updating using recorded earthquake response

  • Nath, Rupam Jyoti;Deb, Sajal Kanti;Dutta, Anjan
    • Earthquakes and Structures
    • /
    • v.4 no.5
    • /
    • pp.471-487
    • /
    • 2013
  • Performance of a prototype base isolated building located at Indian Institute of Technology, Guwahati (IITG) has been studied here. Two numbers of three storeyed single bay RCC framed prototype buildings were constructed for experimental purpose at IITG, one supported on conventional isolated footings and the other on a seismic isolation system, consisting of lead plug bearings. Force balance accelerometers and a 12 channel strong motion recorder have been used for recording building response during seismic events. Floor responses from these buildings show amplification for the conventional building while 60 to 70% reduction has been observed for the isolated building. Numerical models of both the buildings have been created in SAP2000 Nonlinear. Infill walls have been modeled as compression struts and have been incorporated into the 3D models using Gap elements. System identification of the recorded data has been carried out using Parametric State Space Modeling (N4SID) and the numerical models have been updated accordingly. The study demonstrates the effectiveness of base isolation systems in controlling seismic response of isolated buildings thereby leading to increased levels of seismic protection. The numerical models calibrated by relatively low level of earthquake shaking provides the starting point for modeling the non-linear response of the building when subjected to strong shaking.