• 제목/요약/키워드: isolation system

검색결과 1,766건 처리시간 0.029초

위상 보상된 속도 센서를 이용한 6자유도 능동 방진 시스템의 개발 (Development of the Six Degree-of-Freedom Active Vibration Isolation System by Using a Phase Compensated Velocity Sensor)

  • 김용대;김상유;박기환
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1347-1352
    • /
    • 2009
  • Magnetic force driven six degree-of-freedom active vibration isolation system is developed. The velocity sensor using an electromagnetic principle that is commonly used in the vibration control is investigated since its phase lead characteristic causes an instability problem for a low frequency vibration. A lag-type compensator is adopted to reduce the phase lead and the stability test is performed by using a Bode analysis. The performance of the AVIS is validated by comparing with the passive isolation system by using the frequency responses.

영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리 (Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method)

  • 손승찬;성세진
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.409-416
    • /
    • 2000
  • 시스템 특성상 fault tolerant system을 위해 두개의 컨버티를 1개의 전류센서를 사용하여 영상변류기 동적 방식으토 병렬 운전하는 경우 컨버터에 고자이 발생하면 영상변류기 출력은 두 컨버터 공급 전류 차이이므로, 어떤 컨버터에서 고장이 발생하였는지 고정 탐지 및 분리가 곤란히였다. 본 논문에사는 fault tolerant system를 위해 2 개의 컨버터를 병렬 운전하는 경우 캔버터의 고장 탐지 및 분리를 위한 방안올 제시하고 실험을 통하여 제안한 방법의 타당성을 확인하였다.

  • PDF

납-고무받침과 자기유변유체 감쇠기를 이용한 사장교의 내진제어 (Seismic Protection of Cable-stayed Bridges Using LRB and MR Damper)

  • 정형조;박규식;이인원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2003
  • This paper presents the LRB-based hybrid base isolation system employing additional semiactive control devices for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. In this study, ideal magnetorheological dampers (MRDs) are considered as additional semiactive control devices. Numerical simulation results show that the hybrid base isolation system is effective in reducing the structural responses of the benchmark cable-stayed bridge under the historical earthquakes considered. The simulation results also demonstrate that the hybrid base Isolation system employing semiactive MRDs is robust to the stiffness uncertainty of the structure. Therefore, the LRB-based hybrid base isolation system employing MRDs could be appropriate in real applications for full-scale civil infrastructures.

  • PDF

적층고무받침이 설치된 단층 래티스 돔의 동적 거동 특성에 관한 연구 (A Study on the Characteristics of Dynamic Behavior of Single Layer Latticed Domes with Laminated Rubber Bearing)

  • 한상을;배상달
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.425-432
    • /
    • 2001
  • This paper presents the studies of the characteristics of dynamic behavior of single layer latticed domes with laminated rubber bearing and establishes the effectiveness of the system. The base isolation system installed between base and structures reduces the responses due to earthquake motions and increases the natural period of structures. Numerical analysis is carried out using modal superposition method and Newmark-βmethod which is linear acceleration method with (equation omitted) : 1/2 and β : 1/6. The time interval Δt for response calculation is 0.001 sec. Damping ratio is 2 % as Rayleigh damping and El Centro NS(1940) as earthquake motion is the input excitation data. The acceleration response of dome with base isolation is reduced to 30 % of the response of non-isolation system. From the results of the numerical studies on the models, it is confirmed that base isolation system effectively suppresses the responses of the domes subjected to horizontal earthquakes.

  • PDF

원전 주제어실 3차원 층면진시스템의 진동대 실험 연구 (Shaking Table Test Study on 3-Dimensional Floor Isolation of Main Control Room of Nuclear Power Plant)

  • 이경진;함경원;서용표;윤현도
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.409-416
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional Floor Isolation System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate 3-Dimensional Floor Isolation Effectiveness. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

폐고무를 이용한 공공주택 층간소음차단 시스템 (Floor Noise Isolation System of the Residential Buildings Using Waste Rubbers)

  • 오정석;서재찬;김진국
    • 공업화학
    • /
    • 제28권4호
    • /
    • pp.427-431
    • /
    • 2017
  • 최근 공동주택이 증가함에 따라 층간소음문제가 증가하고 있다. 이로 인해 더 효과적인 층간소음저감 시스템이 요구되고 있다. 향후 고층빌딩이 더 많이 건설될 것이므로 이런 시스템은 시장에서 더욱 수요가 요구되어지는 중요한 기술이다. 본 연구에서는 폐고무를 이용하여 신규 바닥 소음 저감 판넬을 설계하고 제작하였다. 실험실 및 실제 필드조건에서 소음 저감을 조사하였다. Field test 결과 경량 및 중량충격음 레벨이 각각 52, 48 dB로 우수한 결과를 보였다. 기존 구조 대비하여 22~42 mm의 두께 저감을 할 수 있었다.

Seismic base isolation of precast wall system using high damping rubber bearing

  • Tiong, Patrick L.Y.;Adnan, Azlan;Rahman, Ahmad B.A.;Mirasa, Abdul K.
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1141-1169
    • /
    • 2014
  • This study is aimed to investigate the seismic performance of low-rise precast wall system with base isolation. Three types of High Damping Rubber Bearing (HDRB) were designed to provide effective isolation period of 2.5 s for three different kinds of structure in terms of vertical loading. The real size HDRB was manufactured and tested to obtain the characteristic stiffness as well as damping ratio. In the vertical stiffness test, it was revealed that the HDRB was not an ideal selection to be used in isolating lightweight structure. Time history analysis using 33 real earthquake records classified with respective peak ground acceleration-to-velocity (a/v) ratio was performed for the remaining two types of HDRB with relatively higher vertical loading. HDRB was observed to show significant reduction in terms of base shear and floor acceleration demand in ground excitations having a/v ratio above $0.5g/ms^{-1}$, very much lower than the current classification of $0.8g/ms^{-1}$. In addition, this study also revealed that increasing the damping ratio of base isolation system did not guarantee better seismic performance particularly in isolation of lightweight structure or when the ground excitation was having lower a/v ratio.

지반-구조물 상호작용 효과를 고려한 지진격리시스템이 적용된 원전 격납건물의 지진 취약도 평가 (Seismic Fragility Evaluation of Isolated NPP Containment Structure Considering Soil-Structure Interaction Effect)

  • 임승현;정형조;김민규;최인길
    • 한국지진공학회논문집
    • /
    • 제17권2호
    • /
    • pp.53-59
    • /
    • 2013
  • Several researches have been studied to enhance the seismic performance of nuclear power plants (NPPs) by application of seismic isolation. If a seismic base isolation system is applied to NPPs, seismic performance of nuclear power plants should be reevaluated considering the soil-structure interaction effect. The seismic fragility analysis method has been used as a quantitative seismic safety evaluation method for the NPP structures and equipment. In this study, the seismic performance of an isolated NPP is evaluated by seismic fragility curves considering the soil-structure interaction effect. The designed seismic isolation is introduced to a containment building of Shin-Kori NPP which is KSNP (Korean Standard Nuclear Power Plant), to improve its seismic performance. The seismic analysis is performed considering the soil-structure interaction effect by using the linearized model of seismic isolation with SASSI (System for Analysis of Soil-Structure Interaction) program. Finally, the seismic fragility is evaluated based on soil-isolation-structure interaction analysis results.

기기면진을 위한 면진장치의 거동분석실험 (II) : 감쇠특성 분석 (An Experimental Study of the Seismic Isolation Systems (or Equipment Isolation : Evaluation of Damping Effect)

  • 전영선;김민규;최인길;김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.411-418
    • /
    • 2003
  • This paper presents the results of experimental studies on the equipment isolation effect in the nuclear containment. for this Purpose, shaking table tests were performed. The natural rubber bearing (NRB) and high damping rubber bearing (HDRB) were selected for the isolation. Peak ground acceleration, damping characteristics of isolation system and frequency contents of selected earthquake motions were considered. finally, it is presented that the NRB and HDRB systems are effective for the small equipment isolation and the damping of isolation systems can be affected to the seismic isolation effect.

  • PDF

Feasibility of a new hybrid base isolation system consisting of MR elastomer and roller bearing

  • Hwang, Yongmoon;Lee, Chan Woo;Lee, Junghoon;Jung, Hyung-Jo
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.323-335
    • /
    • 2020
  • Magnetorheological elastomer (MRE), a smart material, is an innovative material for base isolation system. It has magnetorheological (MR) effect that can control the stiffness in real-time. In this paper, a new hybrid base isolation system combining two electromagnetic closed circuits and the roller bearing is proposed. In the proposed system, the roller part can support the vertical load. Thus, the MRE part is free from the vertical load and can exhibit the maximum MR effect. The MRE magnetic loop is constructed in the free space of the roller bearing and forms a strong magnetic field. To demonstrate the performance of the proposed hybrid base isolation system, dynamic characteristic tests and performance evaluation were carried out. Dynamic characteristic tests were performed under the extensive range of strain of the MRE and the change of the applied current. Performance evaluation was carried out using the hybrid simulation under five earthquakes (i.e., El Centro, Kobe, Hachinohe, Northridge, and Loma Prieta). Especially, semi-active fuzzy control algorithm was applied and compared with passive type. From the performance evaluation, the comparison shows that the new hybrid base isolation system using fuzzy control algorithm is superior to passive type in reducing the acceleration and displacement responses of a target structure.