• Title/Summary/Keyword: isolation period

Search Result 388, Processing Time 0.023 seconds

Response of base-isolated liquid storage tanks to near-fault motions

  • Jadhav, M.B.;Jangid, R.S.
    • Structural Engineering and Mechanics
    • /
    • v.23 no.6
    • /
    • pp.615-634
    • /
    • 2006
  • Seismic response of the liquid storage tanks isolated by the elastomeric bearings and sliding systems is investigated under near-fault earthquake motions. The fault normal and parallel components of near-fault motion are applied in two horizontal directions of the tank. The continuous liquid mass of the tank is modeled as lumped masses known as sloshing mass, impulsive mass and rigid mass. The corresponding stiffness associated with these lumped masses has been worked out depending upon the properties of the tank wall and liquid mass. It is observed that the resultant response of the isolated tank is mainly governed by fault normal component with minor contribution from the fault parallel component. Further, a parametric study is also carried out to study the effects of important system parameters on the effectiveness of seismic isolation for liquid storage tanks. The various important parameters considered are: aspect ratio of tank, the period of isolation and the damping of isolation bearings. There exists an optimum value of isolation damping for which the base shear in the tank attains the minimum value under near-fault motion. The increase of damping beyond the optimum value will reduce the bearing and sloshing displacements but increases the base shear. A comparative performance of five isolation systems for liquid storage tanks is also studied under normal component of near-fault motion and found that the EDF type isolation system may be a better choice for design of isolated tank in near-fault locations. Finally, it is also observed that the satisfactory response can be obtained by analysing the base-isolated tanks under simple cycloidal pulse instead of complete acceleration history.

Effects of the isolation parameters on the seismic response of steel frames

  • Deringol, Ahmet H.;Bilgin, Huseyin
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.319-334
    • /
    • 2018
  • In this paper, an analytical study was carried out to propose an optimum base-isolated system for the design of steel structures equipped with lead rubber bearings (LRB). For this, 5 and 10-storey steel moment resisting frames (MRFs) were designed as Special Moment Frame (SMF). These two-dimensional and three-bay frames equipped with a set of isolation systems within a predefined range that minimizes the response of the base-isolated frames subjected to a series of earthquakes. In the design of LRB, two main parameters, namely, isolation period (T) and the ratio of strength to weight (Q/W) supported by isolators were considered as 2.25, 2.5, 2.75 and 3 s, 0.05, 0.10 and 0.15, respectively. The Force-deformation behavior of the isolators was modelled by the bi-linear behavior which could reflect the nonlinear characteristics of the lead-plug bearings. The base-isolated frames were modelled using a finite element program and those performances were evaluated in the light of the nonlinear time history analyses by six natural accelerograms compatible with seismic hazard levels of 2% probability of exceedance in 50 years. The performance of the isolated frames was assessed in terms of roof displacement, relative displacement, interstorey drift, absolute acceleration, base shear and hysteretic curve.

Isolation of Anaerobic Bacteria from Clinical Specimens (임상검사물에서의 혐기성세균 분리)

  • Chong, Yun-Sop;Kwon, Oh-Hun;Lee, Sam-Uel Y.
    • The Journal of the Korean Society for Microbiology
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 1975
  • Anaerobic bacteria are the major residents of human skin and mucous membrane. The importance, as opportunistic pathogens, of anaerobic bacteria are well recognized because of more population. with decreased defense against bacterial invasion due to chemotherapy, rediation therapy, extensive surgical operation etc. are dealt at hospitals. An analysis of the anaerobe isolation results at Yonsei University Medical Center during the January 1974-May 1975 period was made and the following results were obtained. 1) From 118 patients 146 strains of anaerobes were isolated. Among these 81.3% were nonsporforming anaerobes. Most frequently isolated anaerobes were Pc. asaccharolyticus, Ps. anaerobius, Ps. intermedius, B. fragilis and Cl. perfringens. 2) Anaerobes were frequently isolated from wound, female genital, intraabdominal, and pleuropulmonary specimens. Fewer anaerobes were isolated from blood, spinal fluid and liver specimens. 3) The ratio of anaerobe isolation to total bacteria isolation were; liver 66.7%, intraabdominal 33.3%, pleuropulmonary 28.9%, spinal fluid 5.0% and blood 4.2%. 4) Among the 118 anaerobe isolated patients, 48.3% yielded anaerobes only and rest of them yielded anaerobes together with aerobes. 5) Most of the gram-positive anaerobes were susceptible to the antibiotics tested. Exception was to tetracycline to which appreciable number showed resistance. It was noteworthy that only 48% of B. fragilis was susceptible to tetracycline.

  • PDF

Comparison of Performance between Regular Drilled Shaft and Isolation Tube Drilled Shafts (일반 현장 타설 말뚝과 분리형 현장 타설 말뚝의 거동 비교)

  • Kim, Myung-Hak;O'Neill, Michael W.
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.211-220
    • /
    • 2000
  • An experimental study that included detailed observation of four 305-mm-diameter drilled shafts, one reference shaft of standard design and three test shafts with isolation tubes to mitigate skin friction in the vadose zone of a clay soil profile, is described. The shafts were loaded only by naturally expanding and contraction soil over a period of 17 months. The soil at the test site was instrumented to track suction and elevation changes. Maximum ground surface movements exceeding 40 mm were observed. Heave movements of less than 1.5 mm were observed in the test shafts with isolation tubes, while movements of 5 mm were observed in the reference shaft. Unit side shear loads in the shafts protected by the isolation tubes were minimal compared to those measured in the reference shaft. This indicates that the isolation tubes were very effective.

  • PDF

Seismic isolation of nuclear power plant based on layered periodic foundation

  • Mi Zhao;Qun Chen;Junqi Zhang;Xiuli Du
    • Earthquakes and Structures
    • /
    • v.24 no.4
    • /
    • pp.259-274
    • /
    • 2023
  • In this paper, mechanical properties of periodic foundation made of concrete and rubber are investigated by a parametric study using the finite element method (FEM). Periodic foundation is a special type of seismic isolation foundation used in civil engineering, which is inspired by the meso-scale structure of phononic crystals in solid-state physics. This type of foundation is capable of reducing the seismic wave propagating though the foundation, therefore providing additional protection for the structures. In the FEM analysis, layered periodic foundation is frequently modelled due to its simplicity in numerical modeling. However, the isolation effect of periodic foundation on nuclear power plant has not been fully discussed to the best knowledge of authors. In this work, we construct four numerical models of nuclear power plant with different foundations to investigate the seismic isolation effects of periodic foundations. The results show that the layered periodic foundation can increase the natural period of the nuclear power plant like traditional base isolation systems, which is beneficial to the structures. In addition, the seismic response of the nuclear power plant can also be effectively reduced in both vertical and horizontal directions when the frequencies of the incident waves fall into some specific frequency bandgaps of the periodic foundation. Furthermore, it is demonstrated that the layered periodic foundation can reduce the amplitude of the floor response spectrum, which plays an important role in the protection of the equipment.

Isolation rate of 4 type virus of acute gastroenteritis in full-term neonates during neonatal period (신생아기 급성 장염의 4종 바이러스 양성률)

  • Moon, Soo Kyoung;Lee, Jae In;Yoon, Hye Sun;Ahn, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.855-861
    • /
    • 2007
  • Purpose : The most common causes of acute viral gastroenteritis in newborn period are rotavirus, astrovirus, norovirus and enteric adenovirus. This study was designed to investigate the clinical characteristics, clinical symptoms, isolation rate and distribution of these viruses in full-term neonates during neonatal period. We also studied the influence on the viral isolation rate by postnatal care place and feeding type. Methods : We evaluated 112 healthy full-term neonates who were admitted to Eulji hospital, presenting with symptoms of acute viral gastroenteritis from September 2004 to August 2005. Epidemiologic, clinical and laboratory data were reviewed. Enzyme-linked immunosorbent assay (ELISA) for rotavirus, astrovirus and norovirus and RT-PCR for enteric adenovirus were performed in study subjects.Results : The mean age at the admission was $11.4{\pm}5.4days$, mean weight loss was $5.9{\pm}5.1%$, mean hospitalization duration was $6.3{\pm}3.4days$. Moderate and severe weight loss were expressed in 51.7% and metabolic acidosis was in 13.4%. The percent of living in postnatal care facility (PCF) was 74.1 % and the percent of mixed feeding was 64.3%. Isolation rate of virus was 33%. The most prevalent virus was rotavirus (59.5%), followed by astrovirus (29.7%) and norovirus (10.8%). There was no differences in virus isolation rate by postnatal care place and by feeding type. The rotavirus was main virus in both home group and PCF group. But astrovirus was more detected in PCF and norovirus was more detected in home (P<0.05). According to monthly distribution of virus, acute viral gastroenteritis in newborn period was concentrated in September to December. Conclusion : The isolation rate of 4 type viruses was 33% and rotavirus was the leading cause of acute gastroenteritis during neonatal period. There was no differences in clinical characteristics on each viral groups.

Effect of sodium polyanethol sulfonate on the isolation of Salmonella typhi from blood culture (Sodium polyanethol sulfonate의 혈액배양에서의 Salmonella typhi 분리에 대한 영향)

  • Chong, Yun-Sop
    • The Journal of the Korean Society for Microbiology
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 1974
  • Blood is one of the most important clinical specimens for the isolation of bacteria. A rapid isolation and a high isolation rate of bacteria are very important in blood culture because bacteremic patients are mostly in grave condition. Various blood culture media which support growth of most fastidious bacteria are available commercially. However, growth of bacteria are frequently delayed because of antibacterial activity of blood. Sodium polyanethol sulfonate(Liquoid) has been reported to inactivate the antibacterial substance and disrupt phagocytic cells. The beneficial effect of SPS is well recognized in the isolation of gram-positive bacteria. However, the effect does not seem to be prominent for gram-negative bacilli isolation mainly due to the rapidity of their growth. It has been experienced with Sal. typhi that the growth is much slower than that of other gram-negative bacilli. For the rapid growth of the organism, use of bile broth has been recommended. Although Sal. typhi is the most frequently isolated organism at present, about one half of total isolates are other organisms and, in case bile broth is used, other media which support growth of these organisms should be used together. Fluid thioglycollate medium(FTM) which is always used in blood culture to isolate anaerobes is inferior to brain heart infusion(BHI) for the isolation of aerobes. This study was done to determine the effect of SPS on the isolation of Sal. typhi from blood. During the Sep. 1973 to Sep. 1974 study period, 2460 blood cultures were made from the Severance hospital patients: BHI and FTM sets 1431 specimens, BHI with SPS(0.05%) and FTM sets 396 specimens, BHI and FTM with SPS sets 359 specimens, BHI and BHI with SPS sets 274 specimens. Mean incubation time required for the macroscopic detection of growth of Sal. typhi were 3.5 days on BHI and 2.7 days on BHI with SPS. The 0.8 day difference was statistically significant. On FTM the mean incubation time was 3.8 days while it was 2.9 days on FTM with SPS. The 0.9 day difference was statistically significant. The result on BHI with and without SPS sets showed faster growth on BRI with SPS in 7 specimens and slower growth in one specimen and the remaining 12 showed growth at the same time. These specimens had mean incubation time of 3.2 days on BHI and 2.3 days on BHI with SPS. The 0.9 day difference was statistically significant. This study indicates beneficial effect of SPS for the rapid isolation of Sal. typhi from clinical blood specimens.

  • PDF

Effect of seismic pounding on buildings isolated by triple friction pendulum bearing

  • Amiri, Gholamreza Ghodrati;Shakouri, Ayoub;Veismoradi, Sajad;Namiranian, Pejman
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 2017
  • The current paper investigates the effect of the seismic pounding of neighboring buildings on the response of structures isolated by Triple Friction Pendulum Bearing (TFPB). To this end, a symmetric three-dimensional single story building is modeled for analysis with two specified levels of top deck and base deck, to capture the seismic response of the base isolators and building's roof. Linear elastic springs with different level of gaps are employed to calculate the impact between the buildings. Nonlinear Dynamic Time History Analyses (NDTHA) are conducted for seismic evaluation. Also, five different sizes with four different sets of friction coefficients are assumed for base isolators to cover a whole range of base isolation systems with various geometry configurations and fundamental period. The results are investigated in terms of base shear, buildings' drift and top deck acceleration of the superstructure. The results also indicate the profound effect of the stiffness of the adjacent buildings on the value of the impact they impose to the superstructure. Also, in situations of potential pounding, the increment of the fundamental period of the TFPB base isolator could intensify the impact force up to nearly five-fold.

Determination of Structural Performance Point Utilizing The Seismic Isolation Rubber Bearing Design Method (면진격리 고무베어링 설계법을 이용한 구조물의 성능점 예측)

  • 김창훈;좌동훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.23-30
    • /
    • 2003
  • The seismic base isolation design approach has been reviewed and modified to fit the nonlinear static analysis procedure for determination of the performance point of structures in a simpler way, such an adaptation may be possible for the fact that a structural system under development of damage due to earthquake loading keeps softening to result in period shifting toward longer side. The superiority of the proposed method to the state-of-the-practice approach is that the reasonably accurate performance point can be obtained without constructing the so-called acceleration displacement response spectrum required in application of capacity spectrum method. The validity of the proposed approach was verified by comparing the predicted values to the exact ones presented in the literature.

A Study on Aseismatic Performance of Base Isolation Systems Using Resilient Friction Pot Bearing (탄성마찰포트받침을 적용한 교량의 내진성능에 관한연구)

  • Oh, Ju;Hyeon, Gi Hwan;Park, Yeon Su;Park, Seong-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.127-134
    • /
    • 2008
  • For more districted seismic design and attemped multi-bridge continuity, the existing seismic design is difficulted to treat seismic activity. So, many company applied multi-fixed point and damper or isolator, which is effective for decreasing seismic energy, on period shift, decentralization and damping. But, there is hard to design special bridge with adjusted seismic system because of absence seismic device and insufficient design experience. Therefore, the study on behavior characteristics of designed bridge with various seismic device is performed to utilize the result of this for selection of adequate seismic device.