• 제목/요약/키워드: isolation method

검색결과 1,589건 처리시간 0.032초

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • 제25권2호
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.

주상복합건물에 대한 면진기술의 적용 (Application of Seismic Isolation Technique in Residential-Commercial Building)

  • 이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

Seismic response of spring-damper-rolling systems with concave friction distribution

  • Wei, Biao;Wang, Peng;He, Xuhui;Jiang, Lizhong
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.25-43
    • /
    • 2016
  • The uneven distribution of rolling friction coefficient may lead to great uncertainty in the structural seismic isolation performance. This paper attempts to improve the isolation performance of a spring-damper-rolling isolation system by artificially making the uneven friction distribution to be concave. The rolling friction coefficient gradually increases when the isolator rolls away from the original position during an earthquake. After the spring-damper-rolling isolation system under different ground motions was calculated by a numerical analysis method, the system obtained more regular results than that of random uneven friction distributions. Results shows that the concave friction distribution can not only dissipate the earthquake energy, but also change the structural natural period. These functions improve the seismic isolation efficiency of the spring-damper-rolling isolation system in comparison with the random uneven distribution of rolling friction coefficient, and always lead to a relatively acceptable isolation state even if the actual earthquake significantly differs from the design earthquake.

Combining approach in Fault Detection and Isolation for GPS applications

  • Chey, Jay-Won;Jee, Gyu-In;Lee, Jang-Gyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1949-1952
    • /
    • 2004
  • GPS is widely used for outdoor positioning in many applications. But it is not suitable for positioning in an obstacle environment such as urban area, tunnels and so on, due to variable signal level. So new technology of the positioning is required to provide the consistent error level regardless of any changes in any environment. Abrupt changes of GPS signal can be detected by various fault detection and isolation methods. Conventional FDI (Fault Detection and Isolation) methods are categorized into two approaches. One approach is the snapshot method that uses measurements only at present step. The other approach is the filtering method that uses measurements stacked from previous step to present step. The FDI result of the snapshot method can be considered reliable independently with previous results and the FDI result of the filtering method is more reliable and detection time is a little longer. Therefore combining approach of two methods is proposed for increasing FDI performance in this paper. Three approaches that are the snapshot method, the filtering method and the combining method are compared to show the probability of correct FDI in simulations. The combining approach presents best result of FDI among them and shows the consistent accuracy irrespective of any changes in outdoor environment.

  • PDF

Fabrication of a Flexible Cholesteric Liquid Crystal Display based on Pixel Isolation Method

  • Kwon, Ki-Sun;Kang, Dae-Seung
    • Journal of Information Display
    • /
    • 제6권1호
    • /
    • pp.8-11
    • /
    • 2005
  • A flexible reflective cholesteric liquid crystal display (ChLCD) is fabricated on plastic substrates by using the pixel isolation method. The polymer walls between pixels and the polymer layers in the pixels are formed by two-step UV irradiation. Electro-optical response of the ChLCD with polymer wall and layer is studied and compared with conventional bistable ChLCD cells.

일반공산비 기법을 이용한 INS/GPS 통합시스템의 고장 검출 및 격리 (Fault Detection and Isolation of Integrated Inertial/Satellite Navigation Systems Using the Generalized Likelihood Ratio Test)

  • 신정훈;임유철;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.55-55
    • /
    • 2000
  • This paper presents a fault detection and isolation(FDI) method based on Ceneralized Likelihood Ratio(GLR) test for the tightly coupled INS/GPS. State and measurement GLR tests detect INS or GPS fault. Once the fault is detected, Multi-hypothesized GLR scheme performs the fault isolation between INS and GPS and find which satellite malfunctions. Simulation results show that the GLR method is effective enough to detect and isolate a fault of the integrated navigation system.

  • PDF

차단기 정보를 이용한 계통의 분리 상태 인식의 룰-베이스적 접근 (A Rule-based Approach for the recognition of system isolation state using information on circuit breakers)

  • 박영문;이정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.841-842
    • /
    • 1988
  • For determination of black-out area and restoration area by an expert system for fault section estimation and power system restoration using information from circuit breakers, it is necessary that the recognition of system isolation state and a method of finding the change of system isolation state by the state transition of breakers in isolated system. This paper presents a method of resolving the above problem by rule-based approach.

  • PDF

공기스프링의 최적설계 및 방진 테이블의 능동 제어 (Optimal Design of Air-spring and Active Control of Vibration Isolation Table)

  • 안채헌;김호성;임광혁;진경복;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.909-914
    • /
    • 2006
  • Vibration isolation tables are mostly required in precise measurement and manufacturing system. Among the vibration isolation tables, an air spring is the most favorable equipment because of low resonant frequency and high damping ratio. However, it is difficult to design the air spring with the required stiffness and damping ratio. Futhermore, whenever conventional active control methods are applied to the air spring, it may be difficult to obtain effective control performance due to high nonlinearity of air spring. In this paper, the optimal design of the air spring is performed using genetic algorithm to bring out low resonant frequency and high damping ratio. Also, active control of the vibration isolation table with 3-DOF model is proposed using the adaptive control method. Through experiments, optimal design is shown to be effective. And performance of the proposed control method is verified to be better than those of the passive control method and the conventional active control methods.

  • PDF

Double Faults Isolation Based on the Reduced-Order Parity Vectors in Redundant Sensor Configuration

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권2호
    • /
    • pp.155-160
    • /
    • 2007
  • A fault detection and isolation (FDI) problem is considered for inertial sensors, such as gyroscopes and accelerometers and a new FDI method for double faults is proposed using reduced-order parity vector. The reduced-order parity vector (RPV) algorithm enables us to isolate double faults with 7 sensors. Averaged parity vector is used to reduce false alarm and wrong isolation, and to improve correct isolation. The RPV algorithm is analyzed by Monte-Carlo simulation and the performance is given through fault detection probability, correct isolation probability, and wrong isolation probability.

복합재료를 이용한 시트형 차음재 개발 (Development of Sound Isolation Sheets with Compound Materials)

  • 이동훈;이태근;정성균;이희원;강문;김영배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.415-420
    • /
    • 2000
  • This paper describes a part of the results obtained in the process of the development of thin sound isolation sheets filled mineral compound powder with PVC. The raw materials used are pyrophillite, pottery stone and graphite. The physical properties such as the crystal structures, compositions, and specific gravities, etc. of raw materials are analyzed and discussed from a point of view of sound isolation material. From the analysis of experimental results, the particle size and the additive amount of mineral compound powder for manufacturing sample isolation sheets are decided. The resistant capability against fire of sound isolation sheets including mechanical, thermal and physical properties is tested. The transmission loss measuremenst of sound isolation sheets are performed using two-microphone method in an impedance tube. It is shown that the sound isolation capability of thin sheets has an excellent performance in excess of the object of development.

  • PDF