• 제목/요약/키워드: isolation bearing

검색결과 245건 처리시간 0.028초

LRB 댐퍼 조합형 지진격리장치 개발 및 특성평가실험 (Development of Seismic Isolation Device with LRB and Shock Transmission Units and Its Verification Tests)

  • 서주원;김남식;임진석;유문식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2002
  • The new seismic isolation system (StLRB) is developed, which can separate non-seismic displacements which come from the thermal expansion etc. in LRB design. The StLRB has 3 components, sliding system (PTFE + stainless plate), LRB (lead rubber bearing) and STU (shock transmit units). In this project, the StLRB is designed to apply to the bridge structure by analyzing the characteristics of each component and also the dynamic behavior of the structure was analyzed by non-linear analysis. The verification test was performed to show the two stages separated by STU units. Test results show the effectiveness of both the separation and the seismic isolation performance.

  • PDF

마찰지진격리장치와 구조물의 응답제어: 강체질량모델에서의 적용 (Response Control of Structure by Frictional Base Isolation System : Rigid-Mass Model)

  • 김재관;이원주;김영중;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.426-431
    • /
    • 2001
  • Seismic performance of base isolated rigid-mass model were studied through shaking table tests. Friction pendulum systems (FPS), pure-friction systems with laminated rubber bearing (LRB) were selected for the comparison of performance. Performance of specially designed isolation systems were tested statically using actuator and dynamically using shaking table. Numerical methods were developed to simulate the nonlinear behavior of the frictional base isolation systems. Two models were considered. one is modified Bouc-Wen model considering breakaway coefficient of friction and the other is classical Coulomb model. The results of numerical methods are found to be in very good agreement with test results.

  • PDF

Experimental Study on Seismic Performance of Base-Isolated Bridge

  • Chung, Woo Jung;Yun, Chung Bang;Kim, Nam Sik;Seo, Ju Won
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.51-60
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

실험을 통한 핀타입(pin-type) 강재이력댐퍼의 거동특성연구 (An Experimental Study on the Characteristics of Steel Hysteretic Dampers with Pin-type Elements)

  • 강형택;김인배;이일근;정진혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.257-262
    • /
    • 2003
  • Base isolation bearings are known as an effective system to Protect bridges from the earthquake damage. There are many types of base isolation bearings in the market. Among them, steel hysteretic damper, made of mild steel and one of the oldest ones, has some good features. Since steel hysteretic damper is made of steel and has simple structure, it is cheeper and easier to maintain than other types. Despite the advantages, steel hysteretic damper with pin-type elements has no application in Korea. The steel hysteretic damper with pin-type elements are tested to examin the basic characteristics and to evaluate antiseismic performance. In this paper, the results of the test are presented.

  • PDF

Base-isolated building with high-damping spring system subjected to near fault earthquakes

  • Tornello, Miguel Eduardo;Sarrazin, Mauricio
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.315-340
    • /
    • 2012
  • There are many types of seismic isolation devices that are being used today for structural control of earthquake response in buildings. The most commonly used are sliding bearings and elastomeric bearings, the latter with or without lead core. An alternative solution is the use of steel springs combined with viscoelastic fluid dampers, which is the case discussed in this paper. An analytical study of a three-story building supported on helical steel springs and viscoelastic fluid dampers, GERB Control System (GCS), subjected to near-fault earthquakes is presented. Several earthquakes records have been obtained by the acceleration network installed in the isolated building and in its non-isolated twin since they were finished. These experimental results are analysed and discussed. The aim is to show that the spring-based system can be an alternative for base isolation of small building located near active faults.

기기면진 기반 원전 내진성능 상향 타당성 검토 (Feasibility Study for Seismic Performance Enhancement of NPP Based on Equipment Base Isolation)

  • 이진형;신태명;구경회
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.88-95
    • /
    • 2018
  • In this study, to enhance the seismic performance of nuclear power plants (NPP), a small laminated rubber bearing (LRB) is chosen as a seismic design option of the vulnerable equipment. Prior to the application of equipment base isolation, it is necessary to review the feasibility that the technique contributes enough to the seismic performance of NPP by analysis. At first, some preliminary design of small LRBs for equipment is carried out. Design parameters such as horizontal and vertical stiffnesses, design natural frequencies are checked by calculation and analysis for the four design options considering various upper weights. Performance test of small LRB is to be carried out to verify static performance using the results.

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

납-고무면진장치가 적용된 트러스-아치 구조물의 지진거동 분서 (The Seismic Behavior of the Truss-Arch Structure with Lead Rubber Bearing(LRB))

  • 신민기;김기철;강주원
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.133-138
    • /
    • 2008
  • 본 연구에서는 대공간구조물의 기본적인 동적특성을 가지고 있으며 동시에 가장 간단한 구조이기도 한 아치에 납-고무면진 장치를 적용하여 지진거동을 분석하였다. 대공간구조물의 지진거동은 일반적인 골조구조물의 지진거동과 달리 수평지진에 의하여 수직방향으로 큰 지진응답이 나타나고 있다. 면진장치를 대공간 구조물에 적용할 경우에 수평지진하중에 의하여 수평방향 지진응답이 저감되는 것은 물론 면진장치의 수직강성으로 인하여 수직응답도 현저하게 저감되는 것을 알 수 있었다.

  • PDF

LRB 기초분리장치의 교량 내진효과 (Seismic Effect of LRB Base Isolator on Bridges)

  • 황의승
    • 대한토목학회논문집
    • /
    • 제13권5호
    • /
    • pp.13-18
    • /
    • 1993
  • 본 논문의 목적은 LRB 기초분리장치가 설치된 교량의 내진효과를 해석하는 것이다. 기초분리방법은 지진력이 구조물에 전달되기 전에 그 영향을 최소화시키는 방법으로 현재 건물, 발전소, 교량 등의 구조물에 실용화되고 있다. 본 연구에서는 대표적인 기초분리장치인 Lead Rubber Bearing이 설치된 교량의 단순화된 모델을 개발하고 여러 크기의 LRB에 대하여 지진의 영향을 해석하였다. 단순화된 교량모델의 운동방정식을 Newmark ${\beta}$ 방법에 의해 시간이력해석을 수행하였다. 기초분리장치의 모델로는 이중선형성을 갖는 스프링을, 교각모델로는 비선형성 및 강성저하를 고려한 Q-HYST모델을 사용하였다. 해석예로 미국 네바다주에 소재한 Rose Creek 교량에 대한 남북방향 El Centro지진(1940)의 영향을 해석하였다. 상부구조 횡방향처짐, 교각연성 및 교각 밑면 전단력을 구하였다.

  • PDF

지진시 저층건물 면진구조의 비선형 동적 거동 (Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.