• 제목/요약/키워드: isolated set

검색결과 278건 처리시간 0.024초

지진격리교량의 지진해석을 위한 인공지진파의 작성 (Generation of artificial earthquake time histories for the seismic analysis of base-isolated bridges)

  • 김남식;김재민;이계희;강형택
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.487-494
    • /
    • 2005
  • In this study, a set of artificial earthquake time histories, which can be used for the earthquake-resistant design of seismically isolated highway bridges, was presented. In addition, adequateness of the generated ground accelerations was investigated. These were performed based on the seismic design standard for seismically isolated bridges. Total of 22 acceleration time histories were generated for each soil condition by the spectral method. The time histories were verified to meet the code provisions including (1) mean response spectrum at control frequencies, (2) EPGA (effective peak ground acceleration), and (3) correlation coefficient. Finally, the maximum response corresponding to four time histories and the mean response associated with seven time histories were computed using the generated acceleration time histories, which shows validity of the proposed artificial earthquake time histories.

  • PDF

한국 성인 분변 시료에서 분리한 비피더스균의 유전자 다양성 분석 (Analysis of Genetic Diversity of Bifidobacterium spp. Isolated from Korean Adults Fecal Samples)

  • 배학균;김선옥;박종선;강병용;최성숙;강진양;하남주
    • 약학회지
    • /
    • 제48권1호
    • /
    • pp.20-26
    • /
    • 2004
  • Twelve strains of Bifidobacterium spp. were isolated from the feces of healthy Korean 20∼30 years. The identification of genera from isolates were performed by the microscopic observation and fructose-6-phosphate phosphoketolase (F6PPK) activity which is the key enzyme to distinguish the Bifidobacterium spp. from other anaerobic bacteria. To determine the antibacterial resistance patterns, minimum inhibitory concentration (MIC) of several antibiotics (including anti-tuberculosis agents) was determined. Five of the isolate!, showed the high degree of resistance to vancomycin. To investigate the genetic diversity between isolates and type strain of Bifidobacterium spp. from KCTC, we peformed the RAPD-fingerprinting. Using a total set of four primers, it is possible to distinguish the isolates and Bifidobacterium spp. from KCTC. Thus, Bifidobacterium strains isolated from our samples may be a new species or strains of Bifidobacteriurn genera, and have the potential as a probiotics.

수신호 인식기를 이용한 로봇 사용자 제어 시스템 (Robot User Control System using Hand Gesture Recognizer)

  • 손수원;배정훈;양철종;왕한;고한석
    • 제어로봇시스템학회논문지
    • /
    • 제17권4호
    • /
    • pp.368-374
    • /
    • 2011
  • This paper proposes a robot control human interface using Markov model (HMM) based hand signal recognizer. The command receiving humanoid robot sends webcam images to a client computer. The client computer then extracts the intended commanding hum n's hand motion descriptors. Upon the feature acquisition, the hand signal recognizer carries out the recognition procedure. The recognition result is then sent back to the robot for responsive actions. The system performance is evaluated by measuring the recognition of '48 hand signal set' which is created randomly using fundamental hand motion set. For isolated motion recognition, '48 hand signal set' shows 97.07% recognition rate while the 'baseline hand signal set' shows 92.4%. This result validates the proposed hand signal recognizer is indeed highly discernable. For the '48 hand signal set' connected motions, it shows 97.37% recognition rate. The relevant experiments demonstrate that the proposed system is promising for real world human-robot interface application.

슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템 (An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor)

  • 이준환;이승환;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.15-17
    • /
    • 2007
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank improves dynamic characteristics under sudden load change, and power quality, fuel consumption, and pollutants can be reduced remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

  • PDF

Effects of the isolation parameters on the seismic response of steel frames

  • Deringol, Ahmet H.;Bilgin, Huseyin
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.319-334
    • /
    • 2018
  • In this paper, an analytical study was carried out to propose an optimum base-isolated system for the design of steel structures equipped with lead rubber bearings (LRB). For this, 5 and 10-storey steel moment resisting frames (MRFs) were designed as Special Moment Frame (SMF). These two-dimensional and three-bay frames equipped with a set of isolation systems within a predefined range that minimizes the response of the base-isolated frames subjected to a series of earthquakes. In the design of LRB, two main parameters, namely, isolation period (T) and the ratio of strength to weight (Q/W) supported by isolators were considered as 2.25, 2.5, 2.75 and 3 s, 0.05, 0.10 and 0.15, respectively. The Force-deformation behavior of the isolators was modelled by the bi-linear behavior which could reflect the nonlinear characteristics of the lead-plug bearings. The base-isolated frames were modelled using a finite element program and those performances were evaluated in the light of the nonlinear time history analyses by six natural accelerograms compatible with seismic hazard levels of 2% probability of exceedance in 50 years. The performance of the isolated frames was assessed in terms of roof displacement, relative displacement, interstorey drift, absolute acceleration, base shear and hysteretic curve.

Dynamic response of a base-isolated CRLSS with baffle

  • Cheng, Xuansheng;Liu, Bo;Cao, Liangliang;Yu, Dongpo;Feng, Huan
    • Structural Engineering and Mechanics
    • /
    • 제66권3호
    • /
    • pp.411-421
    • /
    • 2018
  • Although a rubber isolation cushion can reduce the dynamic response of a structure itself, it has little influence on the height of a sloshing wave and even may induce magnification action. Vertical baffles are set into a base-isolated Concrete Rectangular Liquid Storage Structure (CRLSS), and baffles are opened as holes to increase the energy dissipation of the damping. Problems of liquid nonlinear motion caused by baffles are described using the Navier-Stokes equation, and the space model of CRLSS is established considering the Fluid-Solid Interaction (FSI) based on the Finite Element Method (FEM). The dynamic response of an isolated CRLSS with various baffles under an earthquake is analyzed, and the results are compared. The results show that when the baffle number is certain, the greater the number of holes in baffles, the worse the damping effects; when a single baffle with holes is set in juxtaposition and double baffles with holes are formed, although some of the dynamic response will slightly increase, the wallboard strain and the height of the sloshing wave evidently decrease. A configuration with fewer holes in the baffles and a greater number of baffles is more helpful to prevent the occurrence of two failure modes: wallboard leakage and excessive sloshing height.

자기구동 스위치를 이용한 절연된 부스트 변환기의 해석 (Analysis of the Isolated Boost Converter Using Self-Driven Switch)

  • 홍순찬;채수용;정대택;김희선
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.89-98
    • /
    • 2010
  • 절연된 부스트 변환기는 전기적인 절연과 매우 높은 승압을 필요로 하는 응용분야에 적합한 변환기이다. 낮은 입력전압을 높은 출력전압으로 승압하기 위해 필요한 변압기는 volt-sec 평형 조건을 만족하여야 한다. 기존의 절연된 부스트 변환기는 도통구간을 오버랩하여 제어하였으며 이 경우 제어회로가 복잡해지는 문제가 있다. 본 논문에서는 변압기의 volt-sec 평형을 위해 리셋권선을 설치하고 자기구동 스위치를 이용하여 제어회로를 간단하게 구성할 수 있는 절연된 부스트 변환기를 제안하고 해석한다. 마지막으로 출력 10[W]급의 절연된 부스트 변환기를 구성하여 시뮬레이션하고 실험을 수행하여 제안한 변환기의 이론적 해석의 타당성을 입증하였다.

폐기물 저감 인센티브를 고려한 고립지역의 효율적 폐기물 관리 스케줄 (Optimal Scheduling for Efficient Waste Management in Isolated Regions from the Perspective of Waste Reduction Incentives)

  • 황석준;황욱;김현철
    • 자원ㆍ환경경제연구
    • /
    • 제26권3호
    • /
    • pp.399-416
    • /
    • 2017
  • 본 연구는 Keller(1974)의 최적 점검 모형을 이용하여 도서지역과 같은 고립지역에서의 폐기물 누적 발생량 추이를 추적하면서 발생량이 기준치를 초과하는 경우 이를 수거하는 효율적인 관리 스케줄 선택에 관한 문제를 살펴본다. 고립지역에서는 폐기물 발생량이 기준치를 초과하는지 여부를 파악하기 위하여 관리당국의 점검이 일정 기간 동안 적극적으로 자주 시행될 수도 있지만 이에 따른 모니터링 비용이 증가한다는 점과 아울러 기준치를 초과하여 누적되는 폐기물이 바로 수거되지 않는 상태가 지속되면 폐기물 관리기술의 혁신에 대한 사회적 요구도 높아질 수 있다는 점을 동시에 고려하여 최적 점검 스케줄에 대한 함의를 파악한다. 본 연구는 모니터링 비용이 증가하거나 폐기물 관리 시스템의 실패율이 작아지면 관리 당국의 점검은 느슨하게 시행되겠지만 폐기물 누적 발생량이 기준치 이상으로 증대함으로써 고립지역 사회가 겪게 되는 후생 손실이 커지면 점검은 자주 시행될 것을 제시한다. 또한 폐기물 누적 발생량이 기준을 초과함으로써 촉진되는 혁신노력에 따른 사회적 한계편익이 상대적으로 작은 경우에도 적극적인 점검이 최적의 선택임을 제시한다.

Identifying significant earthquake intensity measures for evaluating seismic damage and fragility of nuclear power plant structures

  • Nguyen, Duy-Duan;Thusa, Bidhek;Han, Tong-Seok;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.192-205
    • /
    • 2020
  • Seismic design practices and seismic response analyses of civil structures and nuclear power plants (NPPs) have conventionally used the peak ground acceleration (PGA) or spectral acceleration (Sa) as an intensity measure (IM) of an earthquake. However, there are many other earthquake IMs that were proposed by various researchers. The aim of this study is to investigate the correlation between seismic responses of NPP components and 23 earthquake IMs and identify the best IMs for correlating with damage of NPP structures. Particularly, low- and high-frequency ground motion records are separately accounted in correlation analyses. An advanced power reactor NPP in Korea, APR1400, is selected for numerical analyses where containment and auxiliary buildings are modeled using SAP2000. Floor displacements and accelerations are monitored for the non- and base-isolated NPP structures while shear deformations of the base isolator are additionally monitored for the base-isolated NPP. A series of Pearson's correlation coefficients are calculated to recognize the correlation between each of the 23 earthquake IMs and responses of NPP structures. The numerical results demonstrate that there is a significant difference in the correlation between earthquake IMs and seismic responses of non-isolated NPP structures considering low- and high-frequency ground motion groups. Meanwhile, a trivial discrepancy of the correlation is observed in the case of the base-isolated NPP subjected to the two groups of ground motions. Moreover, a selection of PGA or Sa for seismic response analyses of NPP structures in the high-frequency seismic regions may not be the best option. Additionally, a set of fragility curves are thereafter developed for the base-isolated NPP based on the shear deformation of lead rubber bearing (LRB) with respect to the strongly correlated IMs. The results reveal that the probability of damage to the structure is higher for low-frequency earthquakes compared with that of high-frequency ground motions.

적층 천연고무 면진장치의 장기성능과 크리프에 대한 예측 (Prediction of Long Term Performance and Creep of Laminated Natural Rubber Bearings(NRB))

  • 황기태;서대원;조성국
    • 한국지진공학회논문집
    • /
    • 제17권3호
    • /
    • pp.117-125
    • /
    • 2013
  • Seismic isolation has been considered and utilized in various industries as a way to prevent huge damage on to structures by large earthquakes in various industries. The laminated Laminated rubber bearings is are most frequently used in seismic isolation systems. The structural Structural safety could not be assured unless the performance of the rubber bearing is not guaranteed for the life time of the structure under the consideration that the bearing is a critical structural member to sustain vertical loads in the seismically isolated structure. However, there are few studies on the deterioration problems of rubber bearings during their service life. The long term performance of the rubber bearings was not considered in past designs of seismically isolated structures. This study evaluates the long term performance and creep characteristics of laminated natural rubber bearings that are used in seismically isolated buildings. For the this study, a set of accelerated thermal aging tests and creep tests are were performed on real specimens. The experimental results show that the natural rubber bearings would have a stable change rate of change for durability under severe environmental conditions for a long time.