• 제목/요약/키워드: irradiation time

검색결과 1,442건 처리시간 0.031초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

가임기 여성의 유방암 토모치료 시 난소선량 평가비교 (Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy)

  • 이수형;박수연;최지민;박주영;김종석
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.337-343
    • /
    • 2014
  • 목 적 : 최근 시행되고 있는 가임기 여성의 유방암 토모치료 시 치료영역 외에서 발생되는 산란 및 누설에 의한 난소산란선량을 측정하여 평가하고자 한다. 대상 및 방법 : 인체모형팬텀(Aldorson Rando phantom, USA)을 대상으로 전산화단층영상 2.5 mm 획득 후, Tomotherapy Planning station(Tomotherapy, Inc, USA)을 이용하여 좌측 유방암 환자의 토모테라피 치료계획(Tomotherapy Helical & Tomotherapy Direct)을 수립하였다. 난소의 산량 선량 측정을 위한 측정 지점은 치료계획면적의 30 cm 아래 떨어진 골반의 좌우 위치로 직경 1.5 mm, 길이가 12mm인 저에너지용 보상필터가 들어있는 종류의 유리선량계 (GD-352M, ASAHI TECHNO GLASS CO, Japan)를 이용하여 각 5회씩 측정하여 평균하였으며, 선형지수-선량반응모델을 이용한 장기등가선량(organ equivalent dose: OED)으로 평가하였다. 결 과 : 토모 Helical 및 토모 Direct의 두 가지 방식으로 측정된 난소의 산란선량은 좌측 난소부위가 각각 평균 $64.94{\pm}0.84mGy$, $37.64{\pm}1.20mGy$이고, 우측 난소부위가 평균 $64.38{\pm}1.85mGy$, $32.96{\pm}1.11mGy$로 나타났다. 이는 토모치료 시 비교적 모니터 단위(MU)가 크고 조사 시간이 긴 토모Helical 방식이 토모Direct에 비하여 측정된 산란선량의 양이 보다 약 1.8배 높은 경향을 보였다. 결 론 : 가임기 여성의 유방암 토모테라피 시 발생하는 좌우측 난소의 산량선량은 ICRP 권고 선량이하로, 불임 및 2차 암 발생에 대한 우려 수준은 현저히 낮지만 향후 유방암 발생 연령층이 낮아지고, 토모테라피와 같이 고정밀 영상유도장치를 이용한 방사선치료가 발달할수록, 가임기 여성 환자의 난소산란선량에 대한 임상적 추적조사가 더욱 필요할 것으로 사료된다.

실내녹화용 목본식물 3종의 초기 생육반응에 미치는 광량의 영향 (Effect of Light Intensity on the Growth Responses of Three Woody Plants for Indoor Landscaping)

  • 권계정;박봉주
    • 한국조경학회지
    • /
    • 제46권1호
    • /
    • pp.1-8
    • /
    • 2018
  • 본 연구는 광량이 산호수(Ardisia pusilla), 크루시아(Clusia rosea), 팔손이(Fatsia japonica) 목본식물 3종의 초기 생육 반응에 미치는 영향을 구명하고자 수행하였다. 목본식물 3종을 10cm 포트에 식재한 다음, 광량 15, 30, 60, $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD 4수준으로 광조사 시간은 12/12(명기/암기)로 설정하여 120일 동안 실시하였다. 4주 간격으로 초고, 엽장, 엽폭, 엽록소형광(Fv/Fm), SPAD, Hunter 값의 생육측정과 실험 종료 후 식물체 지상부와 지하부의 생체중과 건조중을 측정하였다. $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 실험기간동안 초고, 엽면적, 지상부와 지하부의 생체중과 건조중 값이 가장 크게 나타났다. 팔손이는 광량이 높을수록 엽장, 엽폭이 컸으며, 그 밖의 식물에서는 광량에 따른 유의적인 차이가 나타나지 않았다. 산호수의 Fv/Fm 값은 60, $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 광량에 대한 스트레스를 받는 것으로 나타났으나, 그 밖의 식물과 광량에서는 Fv/Fm는 모두 정상 범위로 나타나, 스트레스를 받지 않았다. SPAD값은 $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 크루시아만 유의적인 차이를 보였으며, 그 밖의 식물과 광량에서는 유의적인 차이가 나타나지 않았다. 산호수의 Hunter 값은 모든 광량에서 유의적인 차이가 없었으며, 크루시아는 $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서, 팔손이는 $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 L, a, b값에 특이성이 나타났다. $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 산호수 줄기의 성장 폭이 컸으며, 크루시아는 60과 $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$에서 지속적인 성장을 보여, 적정수준의 초고를 유지하기 위해서 이들은 $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$이하의 광량이 필요할 것으로 판단된다.

조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가 (Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques)

  • 남지호;기용간;김동원;김원택
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.26-33
    • /
    • 2007
  • 목 적: 좌측 조기유방암으로 보존수술 후 2차원 또는 3차원 모의치료를 통해 방사선치료를 받은 환자들에서 SPECT (single photon emitted computerized tomography) 영상을 이용하여 심근관류결손의 부위와 빈도를 비교 평가하고자 하였다. 대상 및 방법: 2002년 1월부터 2003년 8월까지 AJCC 병기 T1-T2N0M0인 좌측 조기유방암으로 진단되어 외과에서 보존수술 및 화학요법 후 방사선치료를 시행하였던 32명의 환자들을 대상으로 하였다. X선 투시기를 이용한 2차원 모의치료를 통해 방사선치료를 받은 환자들과 컴퓨터단층촬영 기반의 3차원 모의치료 방법을 이용했던 환자들을 구분하여 연구를 진행하였다. 이들을 대상으로 최소 3년 이상의 추적관찰 기간 후에 technetium-99m-sestamibi gated perfusion SPECT를 시행하여 각 군에서의 심근관류결손의 부위와 빈도를 비교 평가하였고, 각 환자들에서의 심벽의 운동상태와 좌심실의 박출량을 측정하여 분석하였다. 또한 모의치료 과정에서 방사선에 피폭되는 심장영역을 각 군에서 측정하여 심근관류결손과의 상관관계를 알아보았다. 결 과: SPECT 영상 결과, 심근관류결손이 확인된 경우는 전체 32명의 환자 중 11명(34.4%)이었다. 2차원 모의치료를 받은 15명의 환자 중 7명(46.7%)에서, 3차원 모의치료를 받은 17명의 환자 중 4명(23.5%)에서 관류결손이 발견되었는데, 3차원 모의치료를 이용한 환자들에서 심근관류결손의 빈도가 통계적으로 유의하게 낮았다(p=0.0312). 심근관류결손이 확인된 11명 중, 심첨부 결손을 보인 경우가 10명으로 대부분을 차지했다. 심벽의 운동상태와 심실박출량은 모두 정상이었으며, 방사선 조사야에 포함된 심장영역은 3차원 모의치료 군에서 보다 작았으나 양군에서의 심근관류결손과의 통계적 유의성은 확인할 수 없었다. 결 론: 저자들은 이번 연구를 통해 좌측 조기유방암 환자에서 보존수술 후 방사선치료 시 전산화단층촬영 모의치료기를 이용한 3차원 모의치료 방법을 이용하면 심근에 대한 조사용적을 줄일 수 있어 심근관류결손의 빈도를 낮출 수 있음을 확인하였다. 그러나 심근관류스캔상의 결손과 향후 임상적인 허혈성 심장질환으로의 발전 또는 이로 인한 사망률의 증가와의 연관성은 장기간의 추적관찰과 전향적 임상연구를 통해 확인할 필요가 있겠다.

인체말초혈액 림프구와 마우스골수세포에서 중기염색체 분석법과 미소핵검사법을 이용한 방사선적응반응 평가 (Cytogenetic Radiation Adaptive Response Assessed by Metaphase Analysis and Micronuclei Test in Human Lymphocytes and Mouse Bone Marrow Cells)

  • 민정준;범희승;이승연;최근희;정환정;송호천;김지열
    • 대한핵의학회지
    • /
    • 제32권6호
    • /
    • pp.525-533
    • /
    • 1998
  • 목적: 인체 말초혈액 림프구와 마우스의 골수세포에서 중기염색체 분석법과 미소핵 검사법을 각각 실시하여 저선량 방사선에 의한 적응반응이 몇 시간째에 가장 유의하게 나타나는지 알아보고, 중기염색체분석법과 미소핵 검사법간에 서로 상관관계를 분석하였다. 대상 및 방법: 건강한 비흡연자의 말초혈액과 ICR계 수컷 마우스 56마리를 대상으로 하였고, Cs-137 조사기를 이용하여 방사선을 조사하였다. 인체 말초혈액 림프구의 중기염색체 분석법은 세포 100개당 불안정 염색체인 반지형과 이 중 중심체형염색체의 숫자를 계수하였으며, 미소핵 검사법은 이핵세포 1,000개에서 나타나는 미소핵의 수를 계수하였다. 마우스 골수세포는 마우스의 대퇴골에서 추출한 후 중기염색체 분석법에 의해 불안정 염색체인 반지형과 이 중 중심체형 염색체의 숫자를 같은 방법으로 계수하였으며, 미소핵 검사법은 마우스 골수세포의 미성숙적혈구 1,000개에서 나타나는 미소핵의 수를 계수하였다. 대조군은 방사선을 조사하지 않은 군이며, 실험군은 0.18 Gy 및 2 Gy 단일조사군, 0.18 Gy 조사 후 4, 7, 12, 24시간 후에 다시 2Gy를 조사한 군으로 나누었고 각각의 군에서 두 검사법의 상관관계를 분석하였다. 결과: 중기영색체 분석법과 미소핵 검사법 모두에서 저선량방사선을 조사한 후 7시간째에 고선량을 조사한 군에 적응반응이 가장 유의하게 나타남을 알 수 있었다. 또한 중기염색체 분석법과 미소핵검사법은 인체 말초혈액림프구를 이용한 실험(r=0.98, p=0.001)과 마우스골수세포를 이용한 실험(r=0.99, p<0.001) 모두에서 매우 높은 상관관계를 보였다. 결론: 방사선에 대한적응반응이 생체내, 외 실험을 통하여 동신에 확증되었고, 저선량 조사 후 4시간 이후에 시작되어 7시간째에 가장 높은 효과를 나타내는 것으로 보인다. 또한 중기염색체 분석법과 미소핵 검사법은 인체 말초혈액 림프구나 마우스 골수세포를 이용한 실험 모두에서 매우 높은 상관관계가 있음을 알 수 있었고, 방사선에 의한 염색체 손상을 분석하고자 할 때 방법이 간편한 미소핵 검사를 사용하여도 중기 염색체분석법과 같은 결과를 얻을 수 있을 것으로 사료되었다.

  • PDF

상완골 간부 악성 병적골절의 비관혈적 고합성 골수강내 금속정 고정술 (Closed Interlocking Intrmedullary Nailing of Metastatic Diaphyseal Fractures of the Humerus)

  • 박원종;이승구;강용구
    • 대한골관절종양학회지
    • /
    • 제9권1호
    • /
    • pp.1-11
    • /
    • 2003
  • 목적: 전이암 혹은 악성 혈액질환에 의한 상완골의 병적골절의 비관혈적 고합성 골수강내 금속정 삽입술에 대한 임상적 및 방사선학적 결과를 분석하였다. 대상 및 방법: 전이암 혹은 다발성 골수종에 의한 상완골 병적골절 혹은 임박골절로 치료받은 29명중 비관혈적 정복 및 고합성 골수강내 금속정 고정술로 치료 받은 13명 16례를 대상으로 병적기록과 방사선 사진을 분석하였다. 통증 완화와 기능 회복의 평가는 Perez 등의 방법을 변형하여 우수, 양호, 보통, 불량으로 하였다. 결과: 원발암은 다발성 골수종 4명, 폐암 3명, 유방암 2명, 그 외에 선암(adenocarcinoma), 신장암, 위암 및 대장암이 각각 1명이었다. 2명에서는 상완골의 병적골절 후 원발암이 진단되었고, 11명에서는 원발암 진단 후 최소 1개월, 최장 10년, 평균 28.9개월에 상완골 병적골절이 발견되었다. 상완골로의 전이가 발견된 후 최단10주(신장암), 최장 4년 7개월(다발성 골수종), 평균 11.7개월간 생존하였다. 상완골 전이 16례중 13례에서 보통이상의 통증 완화와 기능회복을 보였으나, 수술 후 골 파괴가 진행되었거나 동측 수부로 전이한 3례에서는 불량한 결과를 보였다. 이들 3례와 수술 후 3개월 이전에 사망한 3례를 제외한 10례에서 골유합을 얻을 수 있었으며, 수술 후 감염, 신경마비 등 수술과 관계되는 합병증은 없었다. 결론: 전이암 혹은 악성 혈액질환에 의한 상완골 병적골절은 골절전의 기능상태, 원발암의 종류, 예상되는 생존기간, 환자의 전신상태, 전이암의 국소 및 전신 침범정도에 따라 수술방법을 달리해야 할 것으로 사료된다.

  • PDF

유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가 (Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques)

  • 반태준;전수동;곽정원;백금문
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.183-188
    • /
    • 2012
  • 목 적: 암치료 기술의 발전으로 환자의 생존기간이 길어짐에 따라 치료 이후 삶의 질을 증진하고 치료 방법에 의한 부작용을 줄이는 노력에 관심이 집중되고 있다. 본 연구는 유방암 접선조사 치료에서 치료방법 차이가 반대쪽 유방 산란 선량에 미치는 영향을 분석하고자 하였다. 대상 및 방법: 본원에서 제작한 유방 모형 팬텀의 전산화 단층 영상을 이용하여 이클립스 10.0 (Eclipse 10.0, Varian, USA) 치료계획 시스템을 사용하여 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FIF(Field in Field) plan을 수립하였다. 각 치료계획은 선형가속기 CL-6EX (VARIAN, USA)를 이용하여 400 cGy씩 조사하였고 팬텀의 중심점으로부터 횡축방향으로 1 cm, 3 cm, 5 cm, 9 cm 씩 이동한 지점의 1 cm 깊이에서 전리조(FC 65G, IBA)를 이용하여 내측접선(Medial tangential) 조사와 외측접선(Lateral tangential) 조사에서 발생하는 산란선량을 각각 측정하고 비교 분석하였다. 결 과: 반대쪽 유방 산란 선량을 평가해보았을 때 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FiF (Field in Field) plan에서 처방선량에 대해 각각 6.55%, 4.72%, 2.79%, 2.33%, 1.87%로 나타났다. 내측접선조사와 외측접선 조사로 나누어 보았을 때 내측접선 조사 측정값은 각각 4.94%, 3.33%, 1.55%, 1.17%, 0.77%로 나타났고 외측접선 조사는 각각 1.61%, 1.40%, 1.24%, 1.16%, 1.10%의 산란 선량이 측정되었다. 결 론: 유방암 접선 조사 치료방법 중 반대쪽 유방에 가장 적은 산란 선량이 발생하는 방법은 FiF plan으로 이때 발생한 산란선량은 팬텀 내에서 기인한 선량이 주로 작용하는 것으로 판단되었다. 가장 많은 산란 선량이 발생하는 치료방법은 $30^{\circ}$ wedge plan이었고 쐐기필터를 비롯한 치료 장비에서 기인한 선량은 3.3%로 평가되었다. 치료계획 시스템은 처방선량에 대해 상대적으로 낮은 산란 선량 영역은 정확성이 떨어지는 것으로 나타났다. 치료 조사야 밖으로 발생하는 산란 선량은 처방 선량에 비해 그 양이 적지만 2차 암 발생 확률과 관련이 있다는 점에서 간과할 수 없는 부분이며 방사선 치료를 결정하는데 있어 고려되어야 할 부분으로 사료된다.

  • PDF

소아 고형종양의 고용량 화학요법 후 자가 조혈모세포이식에서 혈액학적 회복과 감염에 영향을 주는 요인 (Factors affecting hematologic recovery and infection in high-dose chemotherapy and autologous stem cell transplantation in patients with high-risk solid tumor)

  • 이정현;이보련;이수현;유건희;성기웅;정혜림;조은주;구홍회
    • Clinical and Experimental Pediatrics
    • /
    • 제49권10호
    • /
    • pp.1079-1085
    • /
    • 2006
  • 목 적 : 본 연구는 다양한 소아 고위험 고형종양에서 이식된 조혈모세포의 수와 조혈기능의 회복속도 나아가 감염과의 상관관계에 대해 분석함으로써 자가 조혈모세포이식에서 안전한 이식을 위해 필요한 최소한의 조혈모세포의 수가 어느 정도인지를 알아보고자 하였다. 방 법 : 2004년 1월부터 2005년 12월까지 2년 동안 삼성서울병원 소아과에서 소아 고형종양을 대상으로 시행된 고용량 화학요법 후 자가 말초혈 조혈모세포이식 72례에서 이식된 조혈모세포의 수와 이식 후 혈액학적 회복속도 및 감염과의 관계를 후향적으로 분석하였다. 결 과 : 중성구 회복속도에 독립적으로 영향을 주는 유일한인자는 이식된 CD34 양성세포의 수였고 혈소판 회복속도에 독립적으로 영향을 주는 인자는 이식된 CD34 양성세포의 수와 이식 전 치료기간이었다. 미생물학적으로 확인된 감염의 빈도는 이식된 CD34 양성세포 수 등 여러 인자와 관련성이 없었다. 나이가 어릴수록, 이식 전 치료기간이 길수록, TBI 혹은 thiotepa가 포함된 고용량 화학요법, 설사가 심한 경우, 이식된 CD34 양성세포의 수가 적은 경우($2{\times}10^6/kg$ 이하) 발열기간이 유의하게 길었다. 그러나 미생물학적으로 확인된 감염의 빈도는 이러한 발열에 영향을 주는 여러 인자와 관련성이 없었다. 이식된 CD34 양성세포의 수를 보다 세분하여 중성구 및 혈소판 회복속도, 고열 지속기간 및 항생제 사용기간을 비교하였을 때 이식된 CD34 양성세포의 수가 적을수록 중성구 및 혈소판 회복속도가 늦어지고 항생제 사용기간이 길어졌으나 고열 지속 기간에는 통계적으로 유의한 차이가 없었다. 결 론 : 이식된 CD34 양성세포의 수에 따라 조혈기능의 회복속도는 분명한 차이가 있지만 미생물학적으로 확인된 감염의 빈도 혹은 임상적으로 유의한 고열 지속기간의 차이는 없었다. 따라서 고용량 화학요법 후 자가 조혈모세포이식 시 가능한 많은 수의 조혈모세포를 이식하는 것이 바람직하지만 임상적으로 충분한 조혈모세포를 채집하지 못한 경우, 1회 이식 시 최소한 $1{\times}10^6/kg$ 이상인 경우에는 임상적으로 수용할 수 있는 생착이 가능하므로 추가적인 조혈모세포 채집을 위해 고용량 화학요법의 적절한 시기를 놓치지 않는 것이 중요할 것으로 사료된다.

HOCl과 $NH_2Cl$에 의한 Hyaluronic Acid의 변성에 있어서 Taurine의 억제 효과 (Inhibitory Effect of Taurine on HOCl-and $NH_2Cl-induced$ Degradation of Hyaluronic Acid)

  • 이정수;이경용;이광수
    • 대한약리학회지
    • /
    • 제28권2호
    • /
    • pp.201-212
    • /
    • 1992
  • 외인성 taurine이 HOCl, $NH_2Cl$과 그밖의 산화성 물질에 의한 hyaluronic acid의 변성에 미치는 영향을 관찰하였다. HOCl, $NH_2Cl$과 그밖의 산화성 물질에 대한 taurine의 제거 작용을 조사하였다. Taurine의 항 산화 작용을 또한 치올 화합물의 작용과 비교 관찰하였다. Hyaluronic acid의 점성도는 HOCl과 $NH_2Cl$에 의하여 뚜렷하게 용량에 따라 감소하였다. Hyaluronic acid에 대한 HOCl의 변성 효과는 $NH_2Cl$에 의한 것보다 현저하였다. Taurine은 HOCl과 $NH_2Cl$에 의한 hyaluronic acid의 변성을 효과적으로 용량에 따라 억제하였다. HOCl의 변성 효과는 DMSO에 의하여 뚜렷하게 억제되었다. $Fe^{2+}$$H_2O_2$에 의한 hyaluronic acid의 변성은 catalase와 DMSO에 의하여 억제되었으나 taurine의 영향은 받지 않았다. Xanthine과 xanthine oxidase의 변성 작용은 SOD와 catalase에 의하여 효과적으로 억제되었으나 taurine의 영향은 받지 않았다. HOCl은 taurine, DMSO, GSH와 MPG에 의하여 유의하게 분해되었다. 파장 250 nm에서의 HOCl의 흡광도와 파장 242 nm에서의 $NH_2Cl$의 흡광도는 taurine의 첨가로 유의하게 증가하였다. $NH_2Cl$과 GSH 또는 MPG의 상호 작용으로 초기에 최대의 흡광도가 관찰되었으나, 이러한 흡광도는 반응 시간에 따라 점차적으로 감소하였다. $Fe^{2+}$$H_2O_2$의 존재하에서 OH 의 생성은 catalase와 DMSO에 의하여 억제되었으나 taurine의 영향은 받지 않았다. DABCO와 DABA에 반응하는 자외선 조사에 따른 $^1O_2$의 생성은 taurine의 영향을 받지 않았다. GSH와 MPG는 HOCl의 변성 작용을 뚜렷하게 억제하였다. 이상의 결과로 부터 hyaluronic acid의 변성을 포함한 조직 구성성분의 산화성 손상에 있어서 taurine의 보호 작용은 산소 유리 라디칼에 대한 제거 작용과 관계없으며 HOCl과 $NH_2Cl$에 대한 제거 작용 그리고 taurine과 HOCl 또는 $NH_2Cl$의 복합체 형성에 기인할 것으로 시사된다. Taurine의 치올 기가 HOCl과 $NH_2Cl$에 의한 변성에 부분적으로 보호 작용을 나타 낼 것으로 추정된다.

  • PDF