• Title/Summary/Keyword: ionizing energy

Search Result 175, Processing Time 0.021 seconds

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

A Kinetics Study of Rn Daughter and Atmospheric Trace Gas Using Alpha Track Detection (알파비적검출방법에 의한 대기중 라돈딸핵종의 화학적 동특성연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.79-83
    • /
    • 1995
  • A number of investigators have reported formation of radiolytic ultrafine particles produced by the interaction of ionizing radiation with atmospheric trace gases. Previous studies have suggested that a very high localized concentration of the hydroxyl radical produced by the radiolysis of water can react with atmospheric trace gases such as $SO_2$ and produce lower vapor pressure compounds that can subsequently nucleate. To determine the trace gas and water vapor concentration dependence of the active, positively charged, first decayt product of radon (Po-218), a well-controlled radon chamber was used in this research. The mobility spectrum of the decay products in the range of $0.07-5.0cm^2/V\;sec$ from the radon chamber was measured using alpha track detector installed inside a specially-designed electrostatic spectrometer. Measurements were taken for different concentrations (0.5ppm to 5ppm) of $SO_2$ in Purified, Compressed air. A kinetics Study following the clustering of $SO_2$ around the $PoO_x^+$ ion in an excess of $SO_2$ for interpretation of the reaction processes was performed.

  • PDF

A Study for Establishment of Diagnostic Reference Level of Patient Dose in Skull Radiography (우리나라의 두부 엑스선검사에서의 환자선량 권고량)

  • Lee, Jung-Eun;Jeong, Jin-Baek;Lee, Hyun-Koo;Lim, Chun-Il;Son, Hye-Kyung;Jin, Hyun-Mi;Kim, Byung-Woo;Yang, Hyun-Kyu;Kim, Hyeog-Ju;Kim, Dong-Sup;Lee, Kwang-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.111-116
    • /
    • 2010
  • Ionizing radiation is most widely used for X-Ray examination among all artificial radiation exposure, it takes up the largest proportion. Even in Korea, the medical exposure by diagnostic X-Ray examination takes up 17.4% of all radiation exposure. It takes up 92% even in artificial radiation exposure. There were 111,567 cases X-Ray radiography for skull diagnosis in 2007, which is 3% annual increase since 2004. Thus, It is need to establish the diagnostic reference level and the medical facilities as a diagnostic reference level to optimize radiation protection of the patients and to reduce the doses of X-ray. In this paper, we survey patient dose on skull radiography - collected from 114 medical facilities nationwide by using human phantom and glass dosimeter. When the patient dose for the skull radiography was measured and evaluated to establish the diagnostic reference level, 2.23 mGy was established for posterior-anterior imaging and 1.87 mGy for lateral imaging was established. The posterior-anterior skull radiography entrance surface dose of 2.23 is less than the guidance level of 5 mGy from the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA), and 1.87 mGy for the lateral skull imaging is less than the guidance level of 3 mGy, which is guided by the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA).

Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation (방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.571-578
    • /
    • 2001
  • To evaluate if the apoptotic fragment assay could be used to estimate the dose prediction after radiation exposure, we examined apoptotic mouse crypt cells per 1,000 cells after whole body $^{60}Co$ $\gamma$-rays and 50MeV ($p{\rightarrow}Be^+$) cyclotron fast neutron irradiation in the range of 0.25 to 1 Gy, respectively. The incidence of apoptotic cell death rose steeply at very low doses up to 1 Gy, and radiation at all doses tigger rapid changes in crypt cells in stem cell region. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for the data of apoptotic fragments was obtained by the linear-quadratic model $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$) after $\gamma$-rays irradiation, while $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$) after neutrons in mice. The dose-response curves were linear-quadratic, and a significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic crypt cells with increasing dose. Both the time course and the radiation dose-response curve for high and low linear energy transfer (LET) radiation modalities were similar. The relative biological effectiveness (RBE) value for crypt cells was 2.072. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morpholoigcal findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis in crypt cells could be a useful in vivo model for studying radio-protective drug sensitivity or screening test, microdosimetric indicator and radiation-induced target organ injury. Since the apoptotic fragment assay is simple, rapid and reproducible in the range of 0.25 to 1 Gy, it will also be a good tool for evaluating the dose response of radiation-induced organ damage in vivo and provide a potentially valuable biodosimetry for the early dose prediction after accidental exposure.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF