• Title/Summary/Keyword: ion-cut

Search Result 94, Processing Time 0.03 seconds

On the Experimental Study about Cutting Resistance of TiN Coated Ceramic Tools (TiN 피복 세라믹공구의 절삭저항에 관한 실험적 연구)

  • 이명재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.307-314
    • /
    • 1999
  • By using AIP(Arc Ion Plating) of a physical vapor deposition for the first time in Korea a ceramic tool whose surface is coated single layeredly with TiN is developed. In addition, cutting resistance appearing in the process of finishing cut of hardened carbon tool steel, STC3 is studied. The principal and radial components of cutting resistance in those cutting conditions appear to be the same or similar, and the feed component is relatively small. The feed component is found to be in proportion to cutting width, and the radial component in proportion to cutting thickness. Owing to coating the cutting resistance of a TiN coated ceramic tool increases compared with that of a general ceramic tool.

  • PDF

Purification and Characterization of Angiotensin I Converting Enzyme lnhibitory Peptides from Enzymatic Hydrolysate of Cod Liver Protein (대구의 간 단백질의 효소적 가수분해물로부터 안지오텐신 I 전환효소 저해 펩타이드의 분리.정제 및 특성)

  • 최영일;박표잠;최정호;변희국;정인철;문성훈;김세권
    • Journal of Life Science
    • /
    • v.10 no.2
    • /
    • pp.140-149
    • /
    • 2000
  • In order to utilize marine processing waste which would normally be discarded, cod liver protein was hydrolysed by ${\alpha}$-chymotrysin, and the hydrolysate was investigated for the new angiotensin I converting enzyme (ACE) inhibitor. Thy hydrolysate was separated into three major types, with molecular weight cut-off (MWCO) values less than 10 kDa, 5 kDa and 1 kDa of ultrafiltration membranes, respectively. ACE inhibitory peptides were isolated from the fractions passed through MWCO 1 kDa membrane, and purified by using ion-exchange chromatography on a SP-Sephadex C-25 column, gel filtration on a Sephadex G-15 column, and HPLC on an ODS column. The purity was identified with capillary electrophoresis. The amino acid sequences of two peptides were Met-Ile-Pro-Pro-Tyr-Tyr (IC50=10.9 ${\mu}$M) and Gly-Leu-Arg-Asn-Gly-Ile (IC50=35.0 ${\mu}$M)

  • PDF

Determination of MDMA and MDA in 44 hair samples during 2002 to 2003

  • Han, Eun-Young;Yang, Won-Kyung;Lee, Jae-Sin;Park, Yong-Hoon;Kim, Eun-Mi;Lim, Mi-Ae;Chung, Hee-Sun
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.112.1-112.1
    • /
    • 2003
  • The qualitative and quantitative analysis of MDMA and MDA in hair samples by GC/MS were reported. Hairs were collected from subjects aged 22-37 years, who were suspected of abusing MDMA. After washing with methanol, hair samples were cut into small pieces, extracted with methanol containing 1 percent hydrochloric acid for 20th, and the solution was evaporated. MDMA or MDA in the extract were determined by GC/MS using selected ion monitoring after derivatization with trifluoroacetic anhydride. (omitted)

  • PDF

Crystal Growth of Transition Metal Ion Doped Rutile

  • Y.M. Yu;Kim, J.Y.;S.J. Jeong
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.09a
    • /
    • pp.71-71
    • /
    • 1998
  • Transition metal ions, such as Sc, V, Cr and Fe, doped rutile crystals were grown by Floating Zone method. Growth conditions for high quality of crystals depending on the concentration of doped ions were investigated. Grown crystals were cut and polished to thin wafers, and then various types of defects such as homogeneities, low angle grain boundaries, scattering centers, and oxygen vacancies were analyzed. The effects of transition metal ions on defect formation are discussed. Results and discussions on absorption and fluorescence spectra and electrical properties of grown crystals were also reported.

  • PDF

MORPHOLOGICAL CHANGES OF DENTIN SURFACE TREATED WITH VARIOUS DENTIN SURFACE CONDITIONERS (수종(數種) 표면처리제(表面處理劑)에 의(依)한 상아질(象牙質) 표면(表面)의 형태(形態) 변화(變化)에 관(關)한 연구(硏究))

  • Cho, Jin-Ho;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.323-334
    • /
    • 1988
  • The purpose of this study was to observe the effect of dentin surface conditioners on the dentin surfaces. Freshly extracted human molars were used in this study. They were stored at $4^{\circ}C$ saline solution before experiment. The crown portions of the teeth were cut in various directions by means of wet diamond point to expose dentin which include transverse, vertical oblique, horizontal and oblique cut to the long axis (Fig. 1). Each tooth was then mounted with self curing acrylic resin in brass ring to expose the flattened dentin surfaces. Final finish was accomplished by grinding the dentin specimens with wet No. 180 and No. 600 grit silicon carbide abrasive paper until a 6.0mm in diameter on a dentin surface was exposed without pulp exposure. The specimens were divided into 9 groups according to the modes of dentin treatment procedure. The following surface treatments were applied on these preparation surfaces; Group 1: unetched (control group) after finish with No. 600 silicon carbide abrasive paper. Group 2: etched with 30% phosphoric acid for 60s Group 3: etched with 10-3 solution for 60s Group 4: Cleaned with 5% NaOCl for 30s Group 5: applied Dentin Adhesit Group 6: cleaned with 5% NaOCl followed by applying the Dentin Adhesit$^{(R)}$ Group 7: applied Photo Bond on the unetched dentin followed by applying the Photo Clearfil Bright Group 8: Etched with 30% phosphoric acid followed by applying Photo Bond and Photo Clearfil Bright Group 9: etched with 10-3 solution followed by applying Photo Bond and Photo Clearfil Bright All the specimens were stored in $37^{\circ}C$ under 50% relative humidity for 24 hours before observations. The specimens in 7, 8, and 9 group, omitting the group 1 to 6, were demineralized in 10% HCl for 10s in order to observe the resin tags. All the specimens in each group were then dried at room temperature. The dried specimens were ion coated with Eiko ion coater (Eiko-engineering Co.), and observed in Hitachi S-430 Scanning electron microscope (Hitachi, Co. Tokyo) at 15KV. The following results were obtained as follows; 1. The smear layers were still remained in group 1,2,4,5, and 6. 2. There is no effect of 5% NaOCl and 30% phosphoric acid on the changes of dentin morphology 3. The dentin treated with 10-3 solution, indicating the tubules opened when the smear layer and the dental plug dissolved. 4. In case of applying the bonding agents the resin tag was not formed at the deep area of dentinal tubules, but in case of applying the Dentin Adhesit$^{(R)}$ that was not.

  • PDF

Analysis of rutile single crystals grown by skull melting method (Skull melting법에 의해 성장된 rutile 단결정 분석)

  • Seok, Jeong-Won;Choi, Jong-Koen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.5
    • /
    • pp.181-188
    • /
    • 2006
  • Rutile single crystals grown by skull melting method were cut parallel and perpendicular to growth axis, and both sides of the cut wafers (${\phi}5.5mmx1.0mm$) were then polished to be mirror surfaces. The black wafers were changed into pale yellow color by annealing in air at 1200 and $1300^{\circ}C$ for $3{\sim}15\;and\;10{\sim}50$ hours, respectively. After annealing, structural and optical properties were examined by specific gravity (S.G), SEM-electron backscattered pattern (SEM-EBSP), X-ray diffraction (XRD), FT-IR transmittance spectra, laser Raman spectroscopy (LRS), photoluminescence (PL) and X-ray photoelectron spectroscopy (XPS). These results are analyzed increase of weight in air, decrease of weight in water and specific gravity, shown secondary phase of needle shape, diffusion of oxygen ion and increase of $Ti^{3+}$. From the above results, we suggest that the skull melting method grown rutile single crystals contain defect centers such as $O_v,\;Ti^{3+},\;O_v-Ti^{3+}$ interstitials and $F^+-H^+$.

Double-Mode SAW Filter for Mobile Communication System (이중 모드 결합에 의한 이동 통신 기기용 SAW 필터)

  • 정영지;진익수;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.4
    • /
    • pp.468-480
    • /
    • 1993
  • In this paper, at first, the characteristics of double mode SAW (DMS) resonator are analysed by applying the wave guide model and coupled mode theory to 1-port resonator. The DMS resonators (2-pole), which are arranged in a close, parallel configuration of two identical 1-port resonators on a single plate, and 4-pole DMS filters are designed and fabricated at the center frequency of 150.15 MHz with 3-dB bandwidth of 80 KHz. The empirical design characteristics are obtained from the comparison of experimental and theoretical values resulted from several fabrications, and the narrow bandpass filters are implemented on the basis of the above empirical results, which can be used to mobile communication systems. A ST-cut quartz substrate is selected for the stable temperature-frequence characteristics, and high resolution photolithography is applied to the fabrication of filter to get the fine electrode patterns.

  • PDF

Effects of Calcinations Temperature on the Electrochemical Properties of Li[Ni0.6Co0.2Mn0.2]O2 Lithium-ion Cathode Materials (리튬 이차전지용 양극활물질 Li[Ni0.6Co0.2Mn0.2]O2의 소성 온도가 전기화학적 특성에 미치는 영향)

  • Yoo, Gi-Won;Jeon, Hyo-Jin;Son, Jong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • Using $Na_2CO_3$ and $MeSO_4$ (Me = Ni, Co and Mn) as starting materials, the precursor of $[Ni_{0.6}Co_{0.2}Mn_{0.2}]CO_3$ has been synthesized by carbonate co-precipitation. The precursor was mixed with $Li_2CO_3$, and calcined at 750, 850, and$950^{\circ}C$ in air. Effect of calcinations temperature on characteristics of $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ cathode materials was investigated. The structure and characteristics of $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ were determined by X-ray diffraction (XRD), Scanning electron microscopy (SEM) and electrochemical measurements. The X-ray diffraction (XRD) results show that the intensity ratio of $I_{(003)}/I_{(104)}$ increased and the R-factor ratio decreased with the increase of calcinations temperature. And Scanning electron microscopy (SEM) result show that the primary particle size increased. Especially, the $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ calcined at $950^{\circ}C$ for 24 H shows excellent electrochemical performances with reversible specific capacity of $165.3mAhg^{-1}$ [cut-off voltage 2.5~4.3 V, 0.1 C($17mAhg^{-1}$)] and good capacity retention of 95.4% after 50th charge/discharge cycles[cut-off voltage 2.5~4.3 V, 1 C($170mAhg^{-1}$)].

Performance Estimation Based on 4D Lookup Table Interpolating and Unit Cell Discharge Tests for Thermal Battery (4D Lookup Table Interpolating을 이용한 단위 전지 방전 시험 기반 열전지 성능 예측)

  • Park, Byeong June;Kim, Ji Youn;Ha, Sang Hyeon;Cho, Jang Hyeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.393-400
    • /
    • 2017
  • For comparison to the Li-ion battery, evaluating a thermal battery must consider additional variables. The first one is the temperature difference between the battery and its unit cell. Thermal batteries and their unit cells have a temperature difference that is caused by the thermal battery activation mechanism and its shape. The second variable is the electrochemical reaction steps. Most Li-ion batteries have a constant electrochemical reaction at the electrode, and battery voltage is affected when the concentration of Li ions is changed. However, a thermal battery has several steps in its electrochemical reaction, and each step has a different potential. In this study, we used unit cell discharge tests based on interpolating a 4D lookup table to estimate the performance of a thermal battery. From the test results, we derived an estimation algorithm by interpolating the table, which is queried from specified profile groups. As a result, we found less than a 5 percent difference between estimation and experiment at the 1.3 V cut-off time.

Synthesis and Electrochemical Performance of Reduced Graphene Oxide/AlPO4-coated LiMn1.5Ni0.5O4 for Lithium-ion Batteries

  • Hur, Jaehyun;Kim, Il Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3553-3558
    • /
    • 2014
  • The reduced graphene oxide(rGO)/aluminum phosphate($AlPO_4$)-coated $LiMn_{1.5}Ni_{0.5}O_4$ (LMNO) cathode material has been developed by hydroxide precursor method for LMNO and by a facile solution based process for the coating with GO/$AlPO_4$ on the surface of LMNO, followed by annealing process. The amount of $AlPO_4$ has been varied from 0.5 wt % to 1.0 wt %, while the amount of rGO is maintained at 1.0 wt %. The samples have been characterized by X-ray diffraction, scanning electron microscopy, and high-resolution transmission electron microscopy. The rGO/$AlPO_4$-coated LMNO electrodes exhibit better cyclic performance compared to that of pristine LMNO electrode. Specifically, rGO(1%)/$AlPO_4$(0.5%)- and rGO(1%)/$AlPO_4$(1%)-coated electrodes deliver a discharge capacity of, respectively, $123mAhg^{-1}$ and $122mAhg^{-1}$ at C/6 rate, with a capacity retention of, respectively, 96% and 98% at 100 cycles. Furthermore, the surface-modified LMNO electrodes demonstrate higher-rate capability. The rGO(1%)/$AlPO_4$(0.5%)-coated LMNO electrode shows the highest rate performance demonstrating a capacity retention of 91% at 10 C rate. The enhanced electrochemical performance can be attributed to (1) the suppression of the direct contact of electrode surface with the electrolyte, resulting in side reactions with the electrolyte due to the high cut-off voltage, and (2) smaller surface resistance and charge transfer resistance, which is confirmed by total polarization resistance and electrochemical impedance spectroscopy.