• Title/Summary/Keyword: ion profile

Search Result 350, Processing Time 0.029 seconds

Site-Directed Mutagenesis Studies with Restriction Endonuclease EcoRV to Identify the Role of Ile91 in Recognition and Catalysis

  • Moon, Byung-Jo;Vipond, I. Barry;Halford, Stephen E.
    • BMB Reports
    • /
    • v.29 no.2
    • /
    • pp.99-104
    • /
    • 1996
  • Site-directed substitutions were made to change the Ile91 of restriction endonuclease EcoRV to either Val, Ala or Gly to identify the role of Ile91 in recognition and catalysis, since substitution of Ile91 with Leu afforded dramatic effects on the activity and properties of restriction endonuclease EcoRV. These changes alter the size of the hydrophobic side chain at position 91 and thus might have revealed the reason for the altered phenotype of Ile91Leu. However, the properties of Ile91Val and Ile91Ala mutants were much like wild type EcoRV, in both activity and metal ion preference. Ile91Gly had very little activity with either $Mg^{2+}$ or $Mn^{2+}$ as cofactors. To try to understand the unusual $Mn^{2+}$ profile of the Ile91Leu mutant, two double mutants, Ile91Leu;Asp90Asn and Ile91Leu;Glu45Met were created. Both double mutants were seriously disabled by the second amino acid change. Ile91Leu;Glu45Met had some residual activity in the $Mn^{2+}$ reaction buffer, whereas the Ile91Leu;Asp90Asn displayed no detectable activity.

  • PDF

Profile control of high aspect ratio silicon trench etch using SF6/O2/BHr plasma chemistry (고종횡비 실리콘 트랜치 건식식각 공정에 관한 연구)

  • 함동은;신수범;안진호
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.69-69
    • /
    • 2003
  • 최근 trench capacitor, isolation trench, micro-electromechanical system(MEMS), micro-opto-electromechanical system(MOEMS)등의 다양한 기술에 적용될 고종횡비(HAR) 실리콘 식각기술연구가 진행되어 지고 있다. 이는 기존의 습식식각시 발생하는 결정방향에 따른 식각률의 차이에 관한 문제와 standard reactive ion etching(RIE) 에서의 낮은 종횡비와 식각률에 기인한 문제점들을 개선하기 위해 고밀도 플라즈마를 이용한 건식식각 장비를 사용하여 고종횡비(depth/width), 높은 식각률을 가지는 이방성 트랜치 구조를 얻는 것이다. 초기에는 주로 HBr chemistry를 이용한 연구가 진행되었는데 이는 식각률이 낮고 많은양의 식각부산물이 챔버와 시편에 재증착되는 문제가 발생하였다. 또한 SF6 chemistry의 사용을 통해 식각률의 향상은 가져왔지만 화학적 식각에 기인한 local bowing과 같은 이방성 식각의 문제점들로 인해 최근까지 CHF3, C2F6, C4F8, CF4등의 첨가가스를 이용하여 측벽에 Polymer layer의 식각보호막을 형성시켜 이방성 구조를 얻는 multi_step 공정이 일반화 되었다. 이에 본 연구에서는 SF6 chemistry와 소량의 02/HBr의 첨가가스를 이용한 single_step 공정을 통해 공정의 간소화 및 식각 프로파일을 개선하여 최적의 HAR 실리콘 식각공정 조건을 확보하고자 하였다.

  • PDF

A Design and Control of Bi-directional Non-isolated DC-DC Converter with Coupled Inductors for Rapid Electric Vehicle Charging System

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungil;Kim, Daegyun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.429-430
    • /
    • 2011
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology with coupled inductors. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. The pre-charging mode employs the staircase shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

A study of detector size effect using Monte Carlo simulation

  • Park, Kwang-Yl;Yi, Byong-Yong;Vahc, Young W.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.36-38
    • /
    • 2004
  • The detector size effect due to the spatial response of defectors is one critical source of inaccuracy in clinical dosimetry and has been a subject of numerous studies. Conventionally, the detector response kernel contains all of the influence that the detector size has on the measured beam profile. Various analytic models for this kernel have been proposed and studied in theoretical and experimental works. Here, we use a method to determine detector response kernel simply by using Monte Carlo simulation and convolution theory. Based on this numerical method and DOSIMETER, an EGS4 Monte Carlo code, the detector response for a Farmer type ion chamber embedded in water phantom is obtained. There exists characteristic difference in the simulated chamber readings between one with carbon graphite wall and the other with Acrylic wail. Using the obtained response and the convolution theory, we are planning to derive the detector response kernel numerically and remove detector size effect from measurements for 6MV, 10${\times}$l0cm2 and 0.5${\times}$10 cm2 photon beam.

  • PDF

Pile-up of phosphorus emitters using thermal oxidation (열산화법에 의한 phosphorus 에미터 pile-up)

  • Boo, Hyun Pil;Kang, Min Gu;Lee, KyungDong;Lee, Jong-Han;Tark, Sung Ju;Kim, Young Do;Park, Sungeun;Kim, Dongwhan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.122.1-122.1
    • /
    • 2011
  • Phosphorus is known to pile-up at the silicon surface when it is thermally oxidized. A thin layer, about 40nm thick from the silicon surface, is created containing more phosphorus than the bulk of the emitter. This layer has a gaussian profile with the peak at the surface of the silicon. In this study the pile-up effect was studied if this layer can act as a front surface field for solar cells. The effect was also tested if its high dose of phosphorus at the silicon surface can lower the contact resistance with the front metal contact. P-type wafers were first doped with phosphorus to create an n-type emitter. The doping was done using either a furnace or ion implantation. The wafers were then oxidized using dry thermal oxidation. The effect of the pile-up as a front surface field was checked by measuring the minority carrier lifetime using a QSSPC. The contact resistance of the wafers were also measured to see if the pile-up effect can lower the series resistance.

  • PDF

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

A Co- mparision of Normocholesterolemia and Hypercholesterolemia in Middle-Aged Men in Kwang-ju (광주지역 중년남성의 정상콜레스테롤혈증군과 고콜레스테롤혈증군의 비교)

  • 허영란;임현숙
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.3
    • /
    • pp.327-337
    • /
    • 1997
  • The purpose of this study was to investigate the differences in anthropometric, hematologic, and lipidologic data between normocholesterolemia and hypercholesterolemia and influencing factors in hypercholesterolemia in middle-aged men in Kwang-ju. 179 middle-aged men were involved. Anthropometric data(body weight, height, body circumferences and skinfold thickness) and hematologic data(blood pressure, fasting blood glucose, albumin and hemoglobin) were measured. Bleed lipid profile(total cholesterol, tr- iglyceride, phospholipid, HDI-cholesterol, LDL-cholesterol and VLDL-cholesterol) were analyzed. To determined using questionnaire. The subjects were classified as hypercholesterolemic based on The Guideline for Korean Hyperlipidemia. body mass index, systolic blood pressure, waist and hip circumference, and triceps, subcostal, abdomen, subscapular and suprailliac skinfold thicknesses of the hypercholesterolemic group were significantly higher than in the normocholesterolemic group. The concentrat- ion of cholesterol, triglyceride, phospholipod. HDL-cholesterol, LDL-cholesterol and VLDL -cholesterol of the hypercholesterolemic group were significantly higher than normocholesterolemic group. The concentration of cholesterol has a significantly positive correlation with body mass index, diastolic blood pressure, waist circumference, waist/thigh ratio and skinfold thickness(triceps, subcostal, abdomen, and supraillic skin- fold thickness). The general tendency of socioeconomec status, frequencyu of meat intake, smoking amounts and duration and duration and drinking frequencies and amount were higher in the hypercholesteolemic group but not significant. In conclusion, hypercholesterolemia in middle-aged men was closely correlated with upper body fat obesity and most of them had an accompanied high triglyceride level tendency.

  • PDF

Development of a Matrix-prespotted Plate for Enhancing the Reproducibility of Serum Glycan Analysis by MALDI-TOF-MS

  • Ha, Mi-Young;In, Young-Ha;Maeng, Hye-Sun;Zee, Ok-Pyo;Lee, Jong-Sik;Kim, Yang-Sun
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.61-64
    • /
    • 2011
  • Matrix Assisted Laser Desorption/Ionization-Time-of-Flight mass spectrometry (MALDI-TOF-MS) is the most widely used MS technique for glycan analysis. However, the poor point-to-point and sample-to-sample reproducibility becomes a limit in glycan biomarker research. A prespotted MALDI plate which overcomes the large crystal formation of 2,5-dihydroxybenzoic acid (DHB) has been developed and applied for glycan analysis. A homogeneous matrix coated surface without a crystal structure was formed on a hydrophilic/ hydrophobic patterned surface using a piezoelectric device. The reproducible MALDI-TOF-MS data have been presented using MALDI imaging of beer glycan as well as serum glycan eluted from 10% and 20% ACN elution fractions. The glycan profile from the serum glycan by MALDI-TOF-MS with a DHB prespotted plate was highly conserved for 10 different spectra and the coefficient of variations of significant ion peaks of MALDI data varies from 3.59 to 19.95.

Purification and Properties of Cyclodextrin Glucanotrnsferase Synthesizing $2-O-{\alpha}-D-Glucopyranosyl{\;}_{L}-Ascorbic$ Acid from Paenibacillus sp. JB-13

  • Bae, Kyung-Mi;Kim, Sung-Koo;Kong, In-Soo;Jun, Hong-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.242-250
    • /
    • 2001
  • A Gram-positive bacterium (strain JB-13) that was isolated from soil as a producer of cyclodextrin glucanotransferase (CGTase) [EC 2.4.1.19] was identified as Panibacillus sp. JB-13. This CGTase could catalyze the transglucosylation reaction from soluble starch to L-ascorbic acid (AA). A main product formed by this enzyme with ${\alpha}-glucosidase$ was identified as $2-O-{\alpha}-D-glucopyranosyl{\;}_{L}-ascorbic$ acid (AA-2G) by the HPLC profile and the elemental analysis. CGTase was purified to homogeneity using ammonium sulfate fractionation, ion-exchange chromatography on DEAE-Seohadex A-50, and gel chromatography on Sephacryl S-200HR. The molecular weight was determined to be 66,000 by both gel chromatography and SDS-PAGE. The isoelectric point of the purified enzyme was 5.3. The optimum pH and temperature was PH 7.0 and $45^{\circ}C$ respectively. The enzyme was stable in the range of pH 6-9 and at temperatures of $75{\circ}C$ or less in the presence of 15 mM ${CaCl_2}.\;{Hg^2+},\;{Mn^+2},{Ag^+},\;and\;{Cu^2+}$ all strongly inhibited the enzyme's activity.

  • PDF

Employing Al Etch Stop Layer for Nb-based SNS Josephson Junction Fabrication Process (Al 식각정지층을 이용한 Nb-based SNS 조셉슨 접합의 제조공정)

  • Choi, J.S.;Park, J.H.;Song, W.;Chong, Y.
    • Progress in Superconductivity
    • /
    • v.12 no.2
    • /
    • pp.114-117
    • /
    • 2011
  • We report our efforts on the development of Nb-based non-hysteretic Josephson junction fabrication process for quantu device applications. By adopting and modifying the existing Nb-aluminum oxide tunnel junction process, we develop a process for non-hysteretic Josephson junction circuits using metal-silicide as metallic barrier material. We use sputter deposition of Nb and $MoSi_2$, PECVD deposition of silicon oxide as insulator material, and ICP-RIE for metal and oxide etch. The advantage of the metal-silicide barrier in the Nb junction process is that it can be etched in $SF_6$ RIE together with Nb electrode. In order to define a junction area precisely and uniformly, end-point detection for the RIE process is critical. In this paper, we employed thin Al layer for the etch stop, and optimized the etch condition. We have successfully demonstrated that the etch stop properties of the inserted Al layer give a uniform etch profile and a precise thickness control of the base electrode in Nb trilayer junctions.