• Title/Summary/Keyword: ion filter

Search Result 191, Processing Time 0.028 seconds

Discharging/Charging Voltage-Temperature Pattern Recognition for Improved SOC/Capacity Estimation and SOH Prediction at Various Temperatures

  • Kim, Jong-Hoon;Lee, Seong-Jun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • This study investigates an application of the Hamming network-dual extended Kalman filter (DEKF) based on pattern recognition for high accuracy state-of-charge (SOC)/capacity estimation and state-of-health (SOH) prediction at various temperatures. The averaged nine discharging/charging voltage-temperature (DCVT) patterns for ten fresh Li-Ion cells at experimental temperatures are measured as representative patterns, together with cell model parameters. Through statistical analysis, the Hamming network is applied to identify the representative pattern that matches most closely with the pattern of an arbitrary cell measured at any temperature. Based on temperature-checking process, model parameters for a representative DCVT pattern can then be applied to estimate SOC/capacity and to predict SOH of an arbitrary cell using the DEKF. This avoids the need for repeated parameter measuremet.

카메라 모듈용 IR Cut filter 코팅 및 열처리 공정 연구

  • Sin, Gwang-Su;Park, Chang-Mo;Kim, Hyo-Jin;Kim, Seon-Hun;Gi, Hyeon-Cheol;Han, Myeong-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.49-49
    • /
    • 2009
  • 카메라 모듈용 적외선 차단 필터를 설계하고 이온빔 증착 장비를 이용한 코팅 공정 후 특성을 조사하였다. 코팅 실험에 앞서 Macleod 프로그램을 이용하여 640nm 차단 필터를 설계하였으며, 실험은 Ion-Assisted Deposition 장비를 사용하여 $TiO_2/SiO_2$ 유전층을 다층 박막으로 증착하였다. 투과도 분석에서 640nm 차단 필터는 설계 곡선과 약 8nm 이내에서 일치하였으며, 갓 성장된 박막 투과도는 400~600nm에서 약 80% 이었으며, 급속열처리 및 열처리 후 약 5% 증가된 투과도를 보였다. 표면거칠기 또한 감소하였다. 따라서 열처리로 인한 재결정화 및 결함감소에 의해 필터특성이 향상되었음을 알 수 있었다.

  • PDF

Quantification of Sampling Artifacts in PM2.5 Inorganic Ion Species using Teflon Filter (테플론 여과지를 이용한 미세입자 무기이온 성분 측정에서의 오차 정량)

  • Kim, Jung-Youn;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.74-83
    • /
    • 2007
  • Artifacts due to inter-particle and gas-particle interactions during PM2.5 sampling were quantified by comparing the measurement results between the annular denuder-filterpack system and the filterpack system without denuder. Measurements were carried in Seoul for 10 days in each season; Nov. 2004, Jan. 2005, Mar. 2005, and Jul. 2005, respectively. In each day, two 12-h samples were obtained. The concentrations of nitrate and chloride showed seasonal variations mainly due to the availability of ammonium to neutralize nitrate or chloride. Nitrates and chloride losses were prominent in summer. Since most of ammonia was used to neutralize sulfuric acid and formed ammonium sulfate in summer, nitrate and chloride could not exist in particles and ammonium loss was smaller than other seasons.

Low Temperature Flow Properties of Palm Biodiesel (팜 바이오디젤의 저온유동성)

  • Jeong, Byung-Hwan;Lee, Kwang-Seok;Kim, Yong-Dai;Shin, Chae-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.602-605
    • /
    • 2007
  • Soybean and rape seed are common feedstocks for biodiesel product ion in USA and Europe, respectively. On the other hand, South Eastern countries like Malaysia and Indonesia have surplus palm crops. However due to substantial amount of saturated fats in palm, the palm biodiesel has poor low temperature properties. To improve the low temperature flow properties as biodiesel, the dependence of the cold filter plugging point (CFPP) on the fatty acid compositions was examined. Two different kinds of biodiesels, palm and soybean biodiesels, were blended with the different volume ratios. And the low temperature flow properties of 0.5%, 1%, and 5% biodiesel in diesel blend fuels was tested. The decrease of CFPP was not observed for BD1 with Palm BD. Also, WDI test didn't exceed in the range of 4oC by the mixing of Palm BD upto 5% in commercial diesels.

  • PDF

Column regeneration for Partisil/Partisphere ion-exchange columns (Partisil/Partisphere 이온 교환 컬럼 재생 가이드)

  • Mark Fever;Gemma Howse
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.5.1-5.3
    • /
    • 2024
  • The document discusses the regeneration of Partisil/Partisphere ion-exchange columns in chromatography. It mentions that column efficiency can diminish with use due to the accumulation of sample and/or mobile phase impurities at the head of the column. This can lead to a change in back pressure, lower column efficiency, and sometimes a change in selectivity. The document outlines a procedure that may restore column performance. The document also provides everyday practices to enhance the lifetime of a column. These include using only high-purity HPLC solvents and buffers, using freshly prepared mobile phases and buffers, filtering mobile phases to remove particulates, using appropriate sample clean-up procedures, using a guard column or pre-column filter, and working within the pressure and flow rate limitations of the column. For the regeneration of Partisil/Partisphere SAX, SCX, WAX, and WCX columns, the document suggests passing 20 column volumes of various mobile phases through the column. These include a buffer wash, distilled water, an acid wash, a chelating wash, a methanol wash, and a buffer for separation. The document emphasizes that not all of these wash steps are required for every column clean-up and that some chromatographers require only a combination of certain steps.

  • PDF

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

Secondary Ion Man Spectrometry: Theory rind Applications in Geosciences (이차이온질량분석기의 원리와 지질학적 응용)

  • 최변각
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.222-232
    • /
    • 2001
  • Secondary ion mass spectrometry (SIMS) uses focused high-speed primary ions to produce secondary ions from sample surface that are analyzed through a mass filter. SIMS is often called as ion microprobe, since it offers a micrometer-scale spatial resolution. Although the precision and accuracy of SIMS are not as good as many conventional mass spectrometers, it has several advantages such as small sample-size requirement, high spatial resolution and capability of in-situ analysis. In the field of geochemistry/cosmochemistry, SIMS is widely used for (1) stable isotope geochemistry of H, C, O, S, etc., (2) geochronology of U/Th-bearing minerals, (3) lateral distribution of trace elements in a mineral, and (4) discovery of presolar grains and investigation of their isotopic compositions.

  • PDF

Lithium-Ion Battery Simulation Error Improvement Using Experiment Votage Data (실험 전압 데이터를 이용한 리튬 이온 배터리 시뮬레이션 오차 개선)

  • Nam, Y.A.;Yoon, C.O.;Kim, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.169-170
    • /
    • 2017
  • 본 논문에서는 Matlab을 이용하여 배터리의 전기적 모델과 내부 파라미터 추출 통해 시뮬레이션을 하였다. IR-drop에 의해 변화한 전압 데이터를 이용하여 부하 전류 변화로 인한 시뮬레이션과 실험 데이터 간의 오차 개선함으로써 배터리 전기적 모델과 실험 전압 데이터를 이용함으로써 확장 칼만 필터(extended kalman filter; EKF) 같은 적응 알고리즘을 사용하지 않고도 오차가 감소된 시뮬레이션이 가능함을 확인하였다.

  • PDF

Development of a Method for Detecting Iodide and Chloride Ions in Infant Formula using an Ion Selectivity Electrode (이온선택성 전극법을 이용한 조제분유중의 염소 및 요오드 이온함량 분석방법 연구)

  • Ko, Jin-Hyouk;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.301-305
    • /
    • 2008
  • This study was carried out to develop an accurate and rapid analysis method to measure the contents of iodide and chloride in infant formula using an ion selectivity electrode. The infant formula SRM 1846 (Standard Reference Material 1846, NIST, USA) was used as a CRM (Certified reference material). Samples were dissolved in water with 3% acetic acid and filtered through filter paper and adjusted to pH 7.0 with 0.1N NaOH. At pH 7.0, the iodide content of the CRM was $1.04{\pm}0.03\;mg/kg$ compared to the specification of $1.11{\pm}0.1\;mg/kg$ of CRM, and the recovery was $93.7{\pm}2.7%$. The chloride content was $5114.3{\pm}240\;mg/kg$ compared to the specification of $4,920{\pm}300mg/kg$ of CRM, and the recovery was $103.9{\pm}4.9%$. Ion selectivity electrodes could be successful1y used to determine the concentration of iodide and chloride ions in infant formula by a simple and rapid pretreatment of sample matrixes.