• 제목/요약/키워드: ion detector

검색결과 187건 처리시간 0.027초

백색광 및 X선 미세탐침 빔라인용 실시간 제어시스템 개발 (Development of Real-time Control System for White bBamline and Microprobe Beamline)

  • 윤종철;이진원;고인수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.748-751
    • /
    • 1997
  • The White Beamline of the Pohang Accelerator Laboratory(PAL) consists of main and second slits, a microprobe system, two ion chambers, a video-microscope, and a Si(Li) detector. These machine components must be controlled remotely through computer system to make user experiments precise and speedy. A real-time computer control system was developed to control and monitor these machine components. A VNIEbus computer with OS-9 real-time operating system was used for low-level data acquisition and control. VME I/O modules were used for step motor control and scaler control. The software has modular structure for maximum performance and easy maintenance. We developed database, I/O driver, and control software. We used PC/Window95 for data logging and operator interface. Visual C++ was used graphical user interface programming. RS232C was used for communication between VME and PC.

  • PDF

Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발 (Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • 제13권5호
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

Validations of Analysis Methods for Decursin and Decursinol Angelate of Angelicae gigantis Radix by Reversed-Phase Liquid Chromatography

  • Lee, Jong-Pill;Chang, Seung-Yeup;Park, Sang-Yong
    • Natural Product Sciences
    • /
    • 제10권6호
    • /
    • pp.262-267
    • /
    • 2004
  • A reversed-phase liquid chromatographic method for decursin and decursinol angelate of Angelicae gigantis Radix, an important crude drug in Korean traditional medicine, was developed and validated. Decursin and decursinol angelate, the structure isomer (pyranocoumarin) each other, are the main organic constituents in Angelicae gigantis Radix. This method was developed using a RP-18 column, UV detector at 280 nm and 50% acetonitrile solution containing 0.01 M sodium dodecyl sulfate and 25 mM sodium dihydrogen phosphate (pH 5.0) as the mobile phase. Various validation parameters were included and evaluated satisfactorily. Linearity was established in range 2-75 mg/ml of decursin and decursinol angelate (correlation coefficient = 0.9997 and 0.9995, respectively). This analytical method showed good accuracy (98.1% and 99.5%, respectively). Precision (repeatability) revealed a relative standard deviation value of 1.71% (decursin) and 3.19% (decursinol angelate). For intermediate precision measure the considered variables were equipment and days. A robustness test showing the influence of deferent counter-ion concentration in mobile phase was also performed.

Simultaneous Determination of Benzoic Acid, Caffeic Acid and Chlorogenic Acid in Seeds of Eriobotrya japonica and their Antibacterial Effect

  • Jeong, Jun-Mo;Lee, Kyoung-In;Kim, Sun-Min
    • Journal of Applied Biological Chemistry
    • /
    • 제57권1호
    • /
    • pp.89-93
    • /
    • 2014
  • We aim to develop a simple method for simultaneous and quantitative determination of benzoic acid, caffeic acid and chlorogenic acid in seeds of Eriobotrya japonica. In addition, antibacterial effect of these three phenolic acids was examined. A basic method is performed on the high performance liquid chromatography system coupled to an UV-detector (230 nm) and reverse phase C-18 column ($4.6{\times}150mm$, $5{\mu}m$). Each phenolic acid was confirmed via liquid chromatography-mass spectrometry (MS)/MS system under the multiple-reaction monitoring with negative-ion electrospray ionization (ESI(-)) mode. It is demonstrated that the method was could be applied to samples for an analytical study of the phenolic acids. On the other hand, three phenolic acids in seeds of E. japonica exhibited antibacterial effect against several pathogenic bacteria. Of these, benzoic acid was found to have stronger antibacterial effect.

기체크로마토그래피/질량분석기에 의한 수질시료 중 4-니트로톨루엔의 분석법 연구 (Analysis of 4-Nitrotoluene in Water by Gas Chromatography/Mass Spectrometry)

  • 이희경;권오승;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • 제15권1_2호
    • /
    • pp.45-51
    • /
    • 2000
  • Analytical method of 4-nitrotoluene (4-NT) in water was developed by 9as chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). 4-NT was extracted with diethyl ether. Organic layer was washed with 5 % sodium chloride solution. The influence of solvent and evaporation condition on extraction of 4-NT were examined. The retention time of 4-NT peak was 7.72 min. Coefficient of variation (CV) of 4-NT (ng) within day and day-to-day was ranged from 7.0 to 14.6% and from 7.7 to 20.8%, respectively. Recovery of 4-NT was ranged from 84 to 109%, and detection limit of 4-H was lese than 1 ng/㎖.

  • PDF

Determination of Impurities in Aluminum by Neutron Activation Analysis

  • Kim, Nak-Bae;Bak, Hae-ill;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.29-38
    • /
    • 1980
  • 중성자 방사화분석법으로 알루미늄중 28개의 미량원소들의 분석을 위하여 방사화학적 분리방법을 개발하였다. 이 분리법은 이온 교환수지와 무기질 이온 교환체를 사용한 군분리에 기초를 둔 것으로서 이온교환통은 유리관을 사용하였으며 용매는 불산용액을 제외한 무기산용액 혹은 유기용매와 혼합된 무기산 용액을 사용하였다. 함량은 분리된 카 원소들의 방사능을 $3"\times3"\;Nal(TI)$ 검출기로 감마선 스펙트럼을 구한 다음 단일비교 체법으로 결정하였다.

  • PDF

서비스 로봇용 결함 허용 미들웨어 (Fault-Tolerant Middleware for Service Robots)

  • 백범현;박홍성
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.399-405
    • /
    • 2008
  • Recently, robot technology is actively going on progress to the field of various services such as home care, medical care, entertainment, and etc. Because these service robots are in use nearby person, they need to be operated safely even though hardware and software faults occur. This paper proposes a Fault-Tolerant middleware for a robot system, which has following two characteristics: supporting of heterogeneous network interface and processing of software components and network faults. The Fault-Tolerant middleware consists of a Service Layer(SL), a Network Adaptation Layer(NAL), a Network Interface Layer(NIL), a Operating System ion Layer(OSAL), and a Fault-Tolerant Manager(FTM). Especially, the Fault-Tolerant Manager consists of 4 components: Monitor, Fault Detector, Fault Notifier, and Fault Recover to detect and recover the faults effectively. This paper implements and tests the proposed middleware. Some experiment results show that the proposed Fault-Tolerant middleware is working well.

HPLC를 이용한 뇨 및 혈액중 Metocurine Iodide의 미량분석 (Microanalysis of Metocurine Iodide in Urine and Blood by HPLC)

  • 김경님;이종필;김효진;김박광
    • 약학회지
    • /
    • 제38권4호
    • /
    • pp.379-388
    • /
    • 1994
  • A new method for the analysis of metocurine iodide in biological fluids was developed. Metocurine iodide was quantitatively extracted with rose bengal from aqueous layer into dichloromethane layer and the amount of metocurine iodide was calculated from the amount of rose bengal which was determined by HPLC with fluorescence detector. It was possible to analyze metocurine iodide without the effect of co-prescribed drugs in the concentration range of $0.09{\sim}9.10\;{\mu}g/ml$. The detection limits of metocurine iodide in urine and blood were 0.8 and 1.2 ng at S/N=3, each respectively.

  • PDF

PLD증착 변수에 따른 II-VI족 화합물 ZnO 반도체 박막의 발광 특성 연구 (Correlation Between Deposition Parameters and Photoluminescence of ZnO Semiconducting Thin Films by Pulsed laser Deposition)

  • 배상혁;윤일구;서대식;명재민;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.246-250
    • /
    • 2001
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of355 nm. In order to investigate the emission properties of ZnO thin films, Pl measurements with an Ar ion laser a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited Pl bands centers around 390, 510 and 640 nm, labeled near ultra-violet(UV), green and orange bands. Structural properties of ZnO thin films are analyzed with X-ray diffraction(XRD).

  • PDF