• 제목/요약/키워드: ion detection

검색결과 665건 처리시간 0.027초

SNP-Based Fetal DNA Detection in Maternal Serum Using the HID-Ion AmpliSeqTM Identity Panel

  • Cho, Sohee;Lee, Ji Hyun;Kim, Chong Jai;Kim, Moon Young;Kim, Kun Woo;Hwang, Doyeong;Lee, Soong Deok
    • The Korean Journal of Legal Medicine
    • /
    • 제41권2호
    • /
    • pp.41-45
    • /
    • 2017
  • Fetal DNA (fDNA) detection in maternal serum is a challenge due to low copy number and the smaller size of fDNA fragments compared to DNA fragments derived from the mother. Massively parallel sequencing (MPS) is a useful technique for fetal genetic analysis that is able to detect and quantify small amounts of DNA. In this study, seven clinical samples of maternal serum potentially containing fDNA were analyzed with a commercial single nucleotide polymorphism (SNP) panel, the HID-Ion $AmpliSeq^{TM}$ Identity Panel, and the results were compared to those from previous studies. Reference profiles for mothers and fetuses were not available, but multiple Y chromosomal SNPs were detected in two samples, indicating that fDNA was present in the serum and thereby validating observations of autosomal SNPs. This suggests that SNP-based MPS can be valuable for fDNA detection, thereby offering an insight into fetal genetic status. This technology could also be used to detect small amounts of DNA in mixed DNA samples for forensic applications.

$CsX^+$(X=Al, Ga, As) 분자이온을 이용한 SIMS의 정량분석 (The Detection of Molecular Ion $CsX^+$(X=Al, Ga, As) for Quantitative SIMS Analysis)

  • 김차연;김선미;김성태;지종열
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.121-125
    • /
    • 1992
  • Secondary Ion Mass Spectrometry (SIMS) is widely known as highly sensitive a surface analysis technique. Efforts for quantification have been hindered, however, by the presence of matrix effects. Here we describe a new technique for the quantitative analysis of AlxGa1-xAs. Instead of Al+, Ga+, As+ ions, CsX+ ions (X=Al, Ga, As) have been detected. Intensity of these molecular ions appears to be much less affected by matrix effects. We have successfully accomplished the compositional analysis with standard deviation better than 2 percent.

  • PDF

Synthesis of Allyl Functionalized Silacrown Ethers and Their Application - A Review

  • Haque, Md Hasanul;Sohn, Honglae
    • 통합자연과학논문집
    • /
    • 제13권2호
    • /
    • pp.41-46
    • /
    • 2020
  • A study is reported about the synthesis processes of various silacrown ether by the reaction of alkoxysilanes with polyethylene glycols (PEG) through transesterification. Crown ether-functionalized carbosilane dendrimers and hybrid crown ethers are also discussed. We will also address the solubility enhancement, phase-transfer catalysis of different silacrown as well as their application as Ion-selective electrodes (ISEs) and as active phase of PVC electrodes for the development of potentiometric sensors for detection of alkali-Ions.

전해커패시터 전해액 중 3차 아민과 4차 암모늄염의 이온쌍 액체크로마토그래피에 의한 분석 (Analysis of Tertiary Amines and Quaternary Ammonium Salts in Electrolyte Solutions of Electrolytic Capacitors by Ion-Pair Liquid Chromatography)

  • 정용순;장철규;이정미;이영훈;김성호
    • 분석과학
    • /
    • 제10권4호
    • /
    • pp.231-239
    • /
    • 1997
  • 역상 이온쌍 고성능 액체크로마토그래피에 의해 3차 아민들과 4차 암모늄염들을 분리하고 정량하였다. 시료들은 간접분광광도법에 의해 검출하였다. 검출 시약과 이온쌍 시약으로는 염화벤질 트리메틸암모늄(BTMACl)과 도데실황산나트륨(DDSANa)을 사용하였다. 전해커패시터의 전해액 중에 포함되어 있는 이들 아민과 암모늄염의 분리 및 정량은 메탄올-물(40:60) 용액에 DDSANa를 0.010M, BTMACl을 0.004M 되게 용해시키고 염화암모늄-암모니아 완충용액(0.05M)으로 pH를 8.5되게 만든 용리액으로 Supelco LC-18이나 ${\mu}$-Bondapak phenyl 컬럼을 통하여 용리시킴으로써 가능하였다. 전해 커패시터들의 전해액을 분석하여 얻은 분석 값의 4차 암모늄염을 첨가하여 만든 커패시터는 임피던스 0.08~0.13의 성능이 우수한 커패시터가 됨도 발견함으로써 분석이 잘 이루어 졌음을 확인하였다.

  • PDF

SIMS 분석조건이 Bismuth Titanate 박막의 깊이방향 조성 해석에 미치는 영향 (Effect of Surface Charging on the SIMS Depth Profile of Bismuth Titanate Thin Film)

  • 김재남;이상업;권혁대;신광수;전웅;박병옥;조상희
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.486-493
    • /
    • 2001
  • 본 연구는 SIMS를 이용한 bismuth titanate 박막의 깊이방향 분석에 있어서 mesh grid를 사용한 경우와 사용하지 않은 경우, offset voltage를 사용한 경우와 사용하지 않은 경우 등 분석조건에 따른 charging effect 그리고 검출한계의 특성을 검토하고자 하였다. 결과에 따르면 -40 V의 offset voltage를 사용하였을 경우는 charging effect의 감소는 물론 검출한계도 낮출 수 있었으나 mesh grid를 사용하였을 경우에는 charging effect는 다소 줄일 수 있었으나 반면 검출 한계는 오히려 높아졌다. O- 일차이온을 적용한 경우는 -40 V의 offset voltage를 사용하였을 때와 동일한 효과를 얻을 수 있었다.

  • PDF

LC/MS를 이용한 카바메이트계 잔류농약 확인방법 (Confirmation of carbamate pesticides by liquid chromatography coupled with electrospray ionization mass spectrometry)

  • 박준조;금모래;고광춘;박병옥;이성식
    • 한국동물위생학회지
    • /
    • 제25권1호
    • /
    • pp.23-29
    • /
    • 2002
  • A method was developed to separate, detect and qualify aldicarb, bendiocarb, carbaryl, carbofuran, ethiofencarb, methomyl, methiocarb, propoxur in meats and fruits. Experimental beef and fork samples were fortified with 0.05mg/kg of carbamate pesticides for analysis. Carbamate-detected pear by HPLC fluorescence detector(HPLC/FLS) are extracted with acetonitril and refined by solid phase extraction(SPE) filled with aminopropyl-bonded silca, In the following step, the injected materials into LC/MS are analyzed to result in the fact that bendiocarb, carbaryl, carbofuran, ethiofencarb, methomyl, methiocarb, propoxur presents several sorts of fraction ions following with; [M+H]$^{+}$, [M+Na]$^{+}$,[M-CONH$CH_3$]$^{+}$, [M-OCONH$CH_3$]$^{+}$. In addition, ethiofencarb presents [M-SCH$_2$$CH_3$]$^{+}$ ion distinctive and aldicarb presents [M+Na]$^{+}$ and [M-OCONH$CH_3$]$^{+}$ ion which is the most decisive fraction ion for pesticides such as bendiocarb, carbaryl, carbofuran, ethiofencarb, methiocarb, methomyl, propoxur excluding [M+H]$^{+}$ ion. However, [M-OCONH$CH_3$]$^{+}$ and [M-OCONH$CH_3$]$^{+}$ fraction ion charactering carbamate pesticides are detected most efficiently with fragment voltage 50ev. As a result, for rluantitative analysis, [M+Na]$^{+}$ ion is the most decisive ion for detection of aldicarb and [M+H]$^{+}$ ion is the most decisive fraction ion for Pesticides such as bendiocarb, carbaryl, carbofuran, ethiofencarb, methiocarb, methomyl, propoxur. Carbaryl-detected pear by HPLC/FLS are analyzed by L/MS and the result shows that [M+H]$^{+}$ and [M-CONH$CH_3$]$^{+}$ ions charactering carbaryl are detected.ering carbaryl are detected.

3차원적 구조분석을 통한 천장관절염의 조기진단 (Early Detection of Sacroilitis by 3-Dimensional Analysis)

  • 전재한;김선일;이두수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.100-102
    • /
    • 1992
  • Currently, detection of sacroilitis is necessary in detect ion of ankylosing spondylitis. So early detection of sacroilitis is needed for early detection of ankylosing spondylitis. But it is difficult to detect sacroiliac abnormalities in early stage by conventional plain X-ray. Therefore, it is performed 3-dimensional volume rendering from the CT image of sacroiliac. Then early detection of sacroilitis is made by analyzing the reconstructed 3-dimensional image.

  • PDF

어류 Metallothionein에 대한 특이적 면역 효소 측정법의 확립에 관한 연구 (The Study on the Establishment of Specific ELISA for the Detection of Fish Metallothionein)

  • 황갑수
    • Environmental Analysis Health and Toxicology
    • /
    • 제11권1_2호
    • /
    • pp.11-17
    • /
    • 1996
  • The purpose of this experiment is to estabilish the sensitive and specific ELISA (enzyme linked immunosorbent assay) system for the detection of fish metallothionein (MT). Silver carp were injected with CA of 1-8mg/kg body wt. 4 times during 10 days. Silver carp was very tolerant species to CA. Cd induced MT in liver was seperated and purified by gel filtration chromatography and ion exchange chromatography and identified by spectrophotometry, native gel electrophoresis and western blot analysis. The rabbit antiserum was produced by immunizing rabbit with lyophilized MT, and the competitive ELISA system was estabilished for the detection of fish MT. In the present ELISA system, the detection limit was about 33 ng/ml. When this ELISA system was employed to determine the MT level in the supernatant sample of fish liver homogenate, the reaction curve showed a good parallel corelationship with the calibration curve over a certain dilution range. The results indicate that the competitive ELISA can be a useful tool for the detection of fish MT in the toxicological study and the evaluation of water pollution.

  • PDF

Nafion-Ethylenediamine이 수식된 유리탄소전극에 의한 Cd(II) 이온의 정량 (Determination of Cadmium(II) Ion Using the Nafion-Ethylenediamine-Modified Glassy Carbon Electrode)

  • 김진아;고영춘;박찬주;박병호;정근호
    • 분석과학
    • /
    • 제14권2호
    • /
    • pp.123-130
    • /
    • 2001
  • Perfluorinated sulfonated polymer-ethylenediamine(Nafion-en)이 화학수식된 유리탄소전극을 사용하여 Cd(II) 이온의 정량에 대해 연구하였다. Cd(II) 이온의 착화제인 ethylenediamine(en)을 nafion에 고정시켜 유리탄소전극 표면에 수식하면 이 수식전극의 en은 Cd(II) 이온과 $[Cd(en)_2]^{2+}$의 착물을 형성한다. Nafion-en이 화학수식된 유리탄소전극에서 시차펄스전압전류법에 의한 Cd(II) 이온의 환원봉우리전위는 $-0.780({\pm}0.005)V$(vs. Ag/AgCl), 측정범위는 $5.0{\times}10^{-7}-2.0{\times}10^{-5}M$, 검출한계(3s)는 $2.20{\times}10^{-7}M$이었다. Nafion-en이 화학수식된 유리탄소전극의 검출한계가 수식되지 않은 유리탄소전극에 비해 약 14배 정도 향상되었다.

  • PDF

A Preliminary Research on Optical In-Situ Monitoring of RF Plasma Induced Ion Current Using Optical Plasma Monitoring System (OPMS)

  • Kim, Hye-Jeong;Lee, Jun-Yong;Chun, Sang-Hyun;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.523-523
    • /
    • 2012
  • As the wafer geometric requirements continuously complicated and minutes in tens of nanometers, the expectation of real-time add-on sensors for in-situ plasma process monitoring is rapidly increasing. Various industry applications, utilizing plasma impedance monitor (PIM) and optical emission spectroscopy (OES), on etch end point detection, etch chemistry investigation, health monitoring, fault detection and classification, and advanced process control are good examples. However, process monitoring in semiconductor manufacturing industry requires non-invasiveness. The hypothesis behind the optical monitoring of plasma induced ion current is for the monitoring of plasma induced charging damage in non-invasive optical way. In plasma dielectric via etching, the bombardment of reactive ions on exposed conductor patterns may induce electrical current. Induced electrical charge can further flow down to device level, and accumulated charges in the consecutive plasma processes during back-end metallization can create plasma induced charging damage to shift the threshold voltage of device. As a preliminary research for the hypothesis, we performed two phases experiment to measure the plasma induced current in etch environmental condition. We fabricated electrical test circuits to convert induced current to flickering frequency of LED output, and the flickering frequency was measured by high speed optical plasma monitoring system (OPMS) in 10 kHz. Current-frequency calibration was done in offline by applying stepwise current increase while LED flickering was measured. Once the performance of the test circuits was evaluated, a metal pad for collecting ion bombardment during plasma etch condition was placed inside etch chamber, and the LED output frequency was measured in real-time. It was successful to acquire high speed optical emission data acquisition in 10 kHz. Offline measurement with the test circuitry was satisfactory, and we are continuously investigating the potential of real-time in-situ plasma induce current measurement via OPMS.

  • PDF