• Title/Summary/Keyword: iohexol

Search Result 15, Processing Time 0.022 seconds

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Anaphylactic Shock Following Nonionic Contrast Medium during Caudal Epidural Injection

  • Lee, Sang Hyun;Park, Jae Woo;Hwang, Byeong Mun
    • The Korean Journal of Pain
    • /
    • v.28 no.4
    • /
    • pp.280-283
    • /
    • 2015
  • Caudal epidural injection is a common intervention in patients with low back pain and sciatica. Even though the complications of fluoroscopically directed epidural injections are less frequent than in blind epidural injections, complications due to contrast media can occur. We report a case of anaphylactic shock immediately after injection of an intravenous nonionic contrast medium (iohexol) during the caudal epidural injection for low back pain and sciatica in a patient without a previous allergic history to ionic contrast media (ioxitalamate). Five minutes after the dye was injected, the patient began to experience dizziness, and the systolic blood pressure dropped to 60 mmHg. Subsequently, the patient exhibited a mild drowsy mental state. About 30 minutes after the subcutaneous injection of 0.2 mg epinephrine, the systolic blood pressure increased to 90 mmHg. The patient recovered without any sequela. Life-threatening complications after injection of intravenous contrast medium require immediate treatment.

A method of bedside urethrography before catheterization in pelvic trauma in Korea: a case report

  • Hojun Lee;Sung Yub Jeong;Kun Hwang
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.451-453
    • /
    • 2023
  • We introduce a convenient method of urethrography before catheterization for patients with pelvic trauma that can be used in a resuscitation area. A 10-mL syringe without a needle was used. X-ray contrast medium (Iohexol, 300 mg I/mL) was administered through the urethral orifice using a 10-mL syringe without needle and a simple pelvic anteroposterior film was taken (70 kilovolt [peak], 50 mAs). A 36-year-old soldier with a saddle injury from a gun barrel was taken to a trauma center. He had a pelvic fracture and complained of hematuria. Bedside urethrography above described was performed. The anterior urethra showed nonspecific findings, but dye leaked from the posterior urethra. Bedside Foley catheter insertion was attempted, but the catheter could not be advanced past the membranous urethra. Thereafter, suprapubic catheterization was performed. On the day of the injury, iliac artery embolization was carried out. The dislocated sacroiliac joint was also treated using open reduction and internal fixation. On hospital day 7, guidewire Foley insertion was performed. This bedside urethrography technique is simple and useful for pelvic fractures in which urethral injury is suspected.

Split-bolus CT urography with synchronous nephrographic and excretory phase in dogs: comparison of image quality with three-phase CT urography and optimal allocation ratio of contrast medium

  • Je, Hyejin;Lee, Sang-Kwon;Jung, Jin-Woo;Jang, Youjung;Chhoey, Saran;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.55.1-55.11
    • /
    • 2020
  • Background: Computed tomography urography (CTU), based on the excretion of contrast medium after its injection, allows visualization of the renal parenchyma and the renal collecting system. Objectives: To determine the optimal contrast medium dose allocation ratio to apply in split-bolus CTU in dogs. Methods: This prospective, experimental, exploratory study used 8 beagles. In 3-phase CTU, unenhanced-, nephrographic-, and excretory-phase images were obtained with a single injection of 600 mg iodine/kg iohexol. In split-bolus CTU, two different contrast medium allocation ratios (30% and 70% for split CTU 1; 50% and 50% for split CTU 2) were used. Unenhanced phase image and a synchronous nephrographic-excretory phase image were acquired. Results: Although the attenuation of the renal parenchyma was significantly lower when using both split CTUs than the 3-phase CTU, based on qualitative evaluation, the visualization score of the renal parenchyma of split CTU 1 was as high as that of the 3-phase CTU, whereas the split CTU 2 score was significantly lower than those of the two others. Artifacts were not apparent, regardless of CTU protocol. The diameter and opacification of the ureter in both split CTUs were not significantly different from those using 3-phase CTU. Conclusions: Split-bolus CTU with a contrast medium allocation ratio of 30% and 70% is feasible for evaluating the urinary system and allows sufficient enhancement of the renal parenchyma and appropriate distention and opacification of the ureter, with similar image quality to 3-phase CTU in healthy dogs. Split-bolus CTU has the advantages of reducing radiation exposure and the number of CT images needed for interpretation.

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF