• Title/Summary/Keyword: inward leakage test

Search Result 6, Processing Time 0.025 seconds

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks (보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도)

  • Han, Don-Hee;Kim, Il Soon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

Evaluation of a New Workplace Protection Factor―Measuring Method for Filtering Facepiece Respirator

  • Sun, Chenchen;Thelen, Christoph;Sanz, Iris Sancho;Wittmann, Andreas
    • Safety and Health at Work
    • /
    • v.11 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • Background: This study aims to assess whether the TSI PortaCount (Model 8020) is a measuring instrument comparable with the flame photometer. This would provide an indication for the suitability of the PortaCount for determining the workplace protection factor for particulate filtering facepiece respirators. Methods: The PortaCount (with and without the N95-CompanionTM) was compared with a stationary flame photometer from Moores (Wallisdown) Ltd (Type 1100), which is a measuring instrument used in the procedure for determining the total inward leakage of the particulate filtering facepiece respirator in the European Standard. Penetration levels of sodium chloride aerosol through sample respirators of two brands (A and B) were determined by the two measuring systems under laboratory conditions. For each brand, thirty-six measurements were conducted. The samples were split into groups according to their protection level, conditioning before testing, and aerosol concentration. The relationship between the gauged data from two measuring systems was determined. In addition, the particle size distribution inside the respirator and outside the respirator was documented. Linear regression analysis was used to calculate the association between the PortaCount (with and without the N95-CompanionTM) and the flame photometer. Results: A linear relationship was found between the raw data scaled with the PortaCount (without N95-CompanionTM) and the data detected by the flame photometer (R2 = 0.9704) under all test conditions. The distribution of particle size was found to be the same inside and outside the respirator in almost all cases. Conclusion: Based on the obtained data, the PortaCount may be applicable for the determination of workplace protection factor.