• Title/Summary/Keyword: inverter function

Search Result 330, Processing Time 0.025 seconds

Resonant Inverter Modeling for SPICE Simulation (SPICE 시뮬레이션을 위한 공진형 인버터 모델링 연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.715-717
    • /
    • 1993
  • Resonant Inverter is analyzed by means of widely available software such a SPICE. In this paper, macro-model of RDCLI is used which is based on converter switch function rather than actual circuit configuration. Computer memory and nm time are greatly reduced compared to micro-model by using macro-model. System overall performance including control strategy and harmonic characteristics can be analyzed easily. This method is suited for stead state analysis and transition analysis at system level.

  • PDF

A Study on characteristic of a double resonant type high frequency inverter using Phase-Shift (Phase-Shift를 이용한 복공진형 고주파 인버터의 특성에 관한 연구)

  • 조규판;김종해;남승식;김동희;노채균;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.109-117
    • /
    • 2000
  • A full bridge type double resonant high frequency resonant inverter to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one and this paper also realize the output control of independence irrespective of the switching frequency using Phase-shift. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters, such as switching frequency, the variation of phase angle ($\phi$) of Phase-shift.

  • PDF

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.

Characteristics analysis of time sharing method VVVF type high frequency resonant inverter (시분할 방식 VVVF형 고주파 공진 인버터의 특성해석)

  • 조규판;원재선;남승식;심광렬;배영호;김동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.20-28
    • /
    • 2002
  • This paper describes the time sharing type high frequency resonant inviter can be used as power of induction heating. This closed inverter can be obtained output frequency three times than switching frequency by composing three unit inviter of conventional Half-Bridge serial resonant inverter in parallel with input power source also, this reduce switching loss because it has ZVS function. The analysis of the proposed circuit is generally described by using the normailized proposed parameters. The principle of basic operating and the its charasteristics are extimated by the parameters such as switching frequency($\mu$), the variation of Phase angle($\phi$) of Phase-shift. Experimental results are presented to verify theoretical discussion. This preposed inverter will be able to be prastically used as a power supply in various fields as induction, heating application, DC-DC converter etc.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Novel Concept of Shunt Active Filter Function Added in PV Generation System (엑티브필터 기능을 추가한 새로운 태양광 발전시스템의 제안)

  • Kim, Bong-Tae;Park, Min-Won;Seong, Ki-Chul;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.296-300
    • /
    • 2001
  • Novel concept of shunt active filter (AF) function added in Photovoltaic (PV) generation system is described in this paper. So far, for the PV generation system has been treated as one of harmonic sources to the power distribution systems, not only a PV system combined with AF but also AF systems using PV module as their power source have never been discussed. The basic structure and control strategy of the PV-AF system are, for the first time, introduced in this work. In order to stabilize the output current of voltage source inverter (VSI), the reference voltage MPPT control is applied. Simulation analysis shows that it is possible to combine AF function to the three-phase grid-connected PV generation system without any physical difficulties, and the performance of the proposed PV-AF system is acceptable and stable as well.

  • PDF

Double-Objective Finite Control Set Model-Free Predictive Control with DSVM for PMSM Drives

  • Zhao, Beishi;Li, Hongmei;Mao, Jingkui
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.168-178
    • /
    • 2019
  • Discrete space vector modulation (DSVM) is an effective method to improve the steady-state performance of the finite control set predictive control for permanent magnet synchronous motor drive systems. However, it requires complex computations due to the presence of numerous virtual voltage vectors. This paper proposes an improved finite control set model-free predictive control using DSVM to reduce the computational burden. First, model-free deadbeat current control is used to generate the reference voltage vector. Then, based on the principle that the voltage vector closest to the reference voltage vector minimizes the cost function, the optimal voltage vector is obtained in an effective way which avoids evaluation of the cost function. Additionally, in order to implement double-objective control, a two-level decisional cost function is designed to sequentially reduce the stator currents tracking error and the inverter switching frequency. The effectiveness of the proposed control is validated based on experimental tests.

HIGH FREQUENCY INVERTER FOR FLUORESCENT LAMP: MODELING SIMULATION AND REGULATION

  • Lee, G.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1100-1103
    • /
    • 1992
  • Two different resonance inverters used as fluorescent lamp ballast are based on the self oscillation at the series resonance of the circuit components. Each circuit is simulated on a computer in order to explain its function and the variation of the circuit variables for each of the circuit elements. Experimental results have bean carried out on the unsymmetrical scheme to indicate the voltage and current of the fluorescent lamp operation at the high frequency.

  • PDF

Advanced Simulation Model for Brushless DC Motor Drives

  • Lee, Byoung kuk;Mehrdad Ehsani
    • Journal of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.124-138
    • /
    • 2003
  • An advanced simulation model for brushless dc (BLDC) motor drives using Matlab is presented. In the developed model, the dynamic characteristics of speed and torque as well as voltages and currents of pwm inverter components can be effectively monitored and analyzed. Therefore, it can be expected that the developed simulation model can be an easy-to-design tool for the development of BLDC motor drives including control algorithms and topological variations with reduced computation time and memory size.

Predictive Control of 5-level NPC/H-bridge inverter (5-레벨 NPC/H-브릿지 인버터의 예측 제어)

  • Cho, Hyun-ki;Kwak, Sang-shin
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.21-22
    • /
    • 2014
  • 본 논문은 5-레벨 NPC/H-브릿지 (Neutral Point Clamped/H-bridge) 인버터의 최적 제어 세트 (finite-control-set) 모델 예측 제어 (MPC: Model Predictive Control) 방법을 제안한다. NPC/H-브릿지 인버터의 출력 전류 제어 및 DC-link 커패시터 전압 균형을 유지하기 위해 출력 전류와 DC-link 커패시터 전압을 예측하고, 하나의 비용 함수 (cost function)을 통해 최적의 스위칭 상태를 출력한다. PSIM 시뮬레이션을 통해 제안된 제어 알고리즘의 검증하였다.

  • PDF