• Title/Summary/Keyword: intraoral radiography

Search Result 89, Processing Time 0.018 seconds

Surgical Treatment of a Periapical Abscess with Suborbital Swelling in Two Dogs (2두의 소형견에서 안와부위종창을 병발한 치근단 농양의 외과적 치료)

  • Han, Hyun-Jung;Kim, Joong-Hyun;Kim, Jun-Yeung;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.476-479
    • /
    • 2006
  • A 9-year-old, female Yorkshire terrier and a 10-year-old, female Maltese were referred to the Veterinary Medical Teaching Hospital of Konkuk University. The dogs were presented with severe swelling and cutaneous sinus tract on the left suborbital lesion. Under general anesthesia, we performed physical, intraoral examinations and survey radiography, and diagnosed as periapical abscess in a left fourth premolar tooth. They were treated with tooth extraction, and the sinus tracts were drained with 0.05% chlorhexidine solution. After teeth extractions, medication applied by the result of antibiotic sensitivity test. During follow-up 10 months later, the left suborbital swelling had completely resolved.

A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface calculus (구내방사선사진과 컴퓨터영상의 치아 인접면 치석 진단능의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 1994
  • 전남대학교 치과대학 학생을 대상으로 평행촬영법으로 촬영한 168장의 구내방사선사진을 디지털 영상으로 변환하여, 필름상의 치석 유무 판독 결과와 모니터상의 판독 결과를 비교하였다. 3명의 구강악안면방사선학 전공 치과의사가 판독을 하되 필름상의 판독 결과를 판정의 기준으로 하였다. 디지털 영상은 상업용 필름-비디오 변환장치, 486DX PC, 그리고 PcVision과 frame grabber을 이용하여 얻었다. 모니터상의 개개 구내방사선사진상은 700×480 pixel로 나타내었다. 디지털 영상의 치석진단의 sensitivity는 0.79-0.90(평균 0.86) 이었고, specificity는 0.03-0.43(평균 0.17) 이었다.

  • PDF

Image enhancement of digital periapical radiographs according to diagnostic tasks

  • Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.31-35
    • /
    • 2014
  • Purpose: This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Materials and Methods: Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. Results: There were significant differences between the image quality of the processed images and that of the original images (P< 0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P< 0.01). Conclusion: Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY (국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구)

  • Kang Yong Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality

  • Kamburoglu, Kivanc;Samunahmetoglu, Ercin;Eratam, Nejlan;Sonmez, Gul;Karahan, Sevilay
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.93-101
    • /
    • 2022
  • Purpose: This study compared the effectiveness of complementary metal-oxide semiconductors (CMOS) and photostimulable phosphor (PSP) plates as intraoral imaging systems in terms of time efficacy, patient comfort, and subjective image quality assessment in real clinical settings. Materials and Methods: Fifty-eight patients (25 women and 33 men) were included. Patients were referred for a full-mouth radiological examination including 1 bitewing radiograph (left and right) and 8 periapical radiographs for each side (left maxilla/mandible and right maxilla/mandible). For each patient, 1 side of the dental arch was radiographed using a CMOS detector, whereas the other side was radiographed using a PSP detector, ensuring an equal number of left and right arches imaged by each detector. Clinical application time, comfort/pain, and subjective image quality were assessed for each detector. Continuous variables were summarized as mean±standard deviation. Differences between detectors were evaluated using repeated-measures analysis of variance. P<0.05 was accepted as significant. Results: The mean total time required for all imaging procedures with the CMOS detector was significantly lower than the mean total time required for imaging procedures with PSP (P<0.05). The overall mean patient comfort scores for the CMOS and PSP detectors were 4.57 and 4.48, respectively, without a statistically significant difference (P>0.05). The performance of both observers in subjectively assessing structures was significantly higher when using CMOS images than when using PSP images for all regions (P<0.05). Conclusion: The CMOS detector was found to be superior to the PSP detector in terms of clinical time efficacy and subjective image quality.

Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

  • Rovaris, Karla;de Faria Vasconcelos, Karla;do Nascimento, Eduarda Helena Leandro;Oliveira, Matheus Lima;Freitas, Deborah Queiroz;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.239-244
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Materials and Methods: Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self­administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (${\alpha}=0.05$). results: A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p = 0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. conclusion: This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

Development of an evidence-based clinical imaging diagnostic guideline for implant planning: Joint recommendations of the Korean Academy of Oral and Maxillofacial Radiology and National Evidence-based Healthcare Collaborating Agency

  • Kim, Min-Ji;Lee, Sam-Sun;Choi, Miyoung;Ha, Eun Ju;Lee, Chena;Kim, Jo-Eun;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Purpose: This study was conducted to develop an evidence-based clinical imaging diagnostic guideline for implant planning, taking into account efficacy, benefits, and risks. Materials and Methods: The guideline development process employed the adaptation methodology used for Korean clinical imaging guidelines(K-CIG). Core databases(Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoMGI) were searched for guidelines. The retrieved articles were analyzed by 2 reviewers, and articles were selected using well-established inclusion criteria. Results: The search identified 294 articles, of which 3 were selected as relevant guidelines. Based on those 3 guidelines, 3 recommendations for implant planning were derived. Conclusion: We recommend radiography or cone-beam computed tomography (CBCT) scanning for individual patients judged to require a cross-sectional image after reading of a panoramic X-ray image and a conventional intraoral radiological image. Various steps should be taken to raise awareness of these recommendations among clinicians and the public, and K-CIG should be regularly reviewed and revised.

Evaluation of mechanical and projective standardization in digital subtraction radiography (디지털 공제 방사선 촬영술에 있어서 기계적 및 투사적 규격화의 평가)

  • Choi Bong-In;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.215-224
    • /
    • 1998
  • The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleling technique with Rinn XCP only and with occlusal bite registration for geometric standardization using bilateral mandibular premolar and molar regions of two dry human skulls. 1. The SD of the overall subtraction images of the premolars and molars of the non-reconstructed, that is, the manual superimposition showed statistically significant difference between the non-registered and registered groups. 2. In non-reconstructed and non-registered cases, the quality of the subtraction images were improved when superimposition was focally done and this was more evident in areas where the radiographic images tend to be distorted due to anatomic reasons. 3. In non-reconstructed and registered cases, the subtraction images were consistent regardless of the anatomic site or the focus of superimposition. This means that the geometric standardization with only occlusal bite registration could produce serial radiographs which is suitable for subtraction. 4. The SD of the overall subtraction images of the premolars and molars of the reconstructed, that is, the automatic superimposition showed statistically insignificant difference between the non-registered and registered groups. This means that using reconstruction, subtraction radiography is possible without occlusal bite registration. 5. In reconstructed and non-registered cases, compatible quality of the subtraction images were obtained regardless of the anatomic site or area of the corresponding points. 6. In reconstructed and registered cases, best subtraction images whose quality showed sensitivity to the areas of corresponding points were obtained.

  • PDF

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.